PowerEdge Servers Error and Event Messages Reference Guide
CXL—CXL devices Event Messages
CXL1000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Downstream Port Containment event was detected on the CXL device at PCIE segment arg1, slot arg2.
- Arguments
- arg1 = seg
- arg2 = slot
- Detailed Description
- An error has triggered a Downstream Port Containment event on the CXL device at the location identified in the message. The operating system is automatically notified about this to make an attempt to recover from the issue.
- Recommended Response Action
- Do the following: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) Reconnect the power cords. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Warning
- Trap/EventID
- 3778
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Downstream Port Containment event was detected on the CXL device at drive or module bay arg1, slot arg2, segment arg3.
- Arguments
- arg1 = bay
- arg2 = number
- arg3 = seg
- Detailed Description
- An error has triggered a Downstream Port Containment event on the CXL device at the location identified in the message. The operating system is automatically notified about this to make an attempt to recover from the issue.
- Recommended Response Action
- Do the following: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) Reconnect the power cords. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Warning
- Trap/EventID
- 3778
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Downstream Port Containment event was detected on the CXL device connected to PCIe segment arg1, bus arg2, device arg3, function arg4.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = function
- Detailed Description
- An error has triggered a Downstream Port Containment event on the CXL device connected to the PCIe bus in the message. The operating system is automatically notified about this to make an attempt to recover from the issue.
- Recommended Response Action
- Do the following: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) Reconnect the power cords. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Warning
- Trap/EventID
- 3778
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An informational event is detected on the CXL device at PCIe slot arg1, segment arg2. arg3.
- Arguments
- arg1 = slot
- arg2 = seg
- arg3 = (Extended ID: code)
- Detailed Description
- An informational event is detected on the CXL device identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (CXL = CXL devices)
- Severity
- Informational
- Trap/EventID
- 3779
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An informational event is detected for the CXL device at drive or module bay arg1, slot arg2, segment arg3. arg4.
- Arguments
- arg1 = bay
- arg2 = number
- arg3 = seg
- arg4 = (Extended ID: code)
- Detailed Description
- An informational event is detected on the CXL device identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (CXL = CXL devices)
- Severity
- Informational
- Trap/EventID
- 3779
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An informational event is detected on the CXL device connected to PCIe segment: arg1, bus arg2, device arg3, function arg4. arg5.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = function
- arg5 = (Extended ID: code)
- Detailed Description
- An informational event is detected on the CXL device connected to the PCIe bus identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (CXL = CXL devices)
- Severity
- Informational
- Trap/EventID
- 3779
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1020
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A self-serviceable event is detected on the CXL device at PCIe slot arg1, segment arg2. arg3.
- Arguments
- arg1 = slot
- arg2 = seg
- arg3 = (Extended ID: code)
- Detailed Description
- A self-serviceable event is detected on the CXL device identified in the message.
- Recommended Response Action
- Do the following: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) Reconnect the power cords. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Warning
- Trap/EventID
- 3778
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1021
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A self-serviceable event is detected on the CXL device at drive or module bay arg1, slot arg2, segment arg3. arg4.
- Arguments
- arg1 = bay
- arg2 = number
- arg3 = seg
- arg4 = (Extended ID: code)
- Detailed Description
- A self-serviceable event is detected on the CXL device at the location identified in the message.
- Recommended Response Action
- Do the following: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) Reconnect the power cords. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Warning
- Trap/EventID
- 3778
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1022
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A self-serviceable event is detected on the CXL device connected to PCIe segment arg1, bus arg2, device arg3, function arg4. arg5.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = function
- arg5 = (Extended ID: code)
- Detailed Description
- A self-serviceable event is detected on the CXL device connected to the PCIe bus in the message.
- Recommended Response Action
- Do the following: 1) Make sure the device, BIOS, and iDRAC are updated to the latest firmware. 2) Perform an AC power-cycle operation on the server by doing the following: a) Disconnect the power cords. b) Wait 30 seconds. c) Reconnect the power cords. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Warning
- Trap/EventID
- 3778
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1030
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical event was detected for the CXL device at PCIe slot arg1, segment arg2. arg3.
- Arguments
- arg1 = slot
- arg2 = seg
- arg3 = (Extended ID: code)
- Detailed Description
- A critical event is detected on the CXL device identified in the message.
- Recommended Response Action
- Do the following: 1) Power off the server. 2) Manually remove and reinstall the CXL device. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Critical
- Trap/EventID
- 3777
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1031
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical event is detected on the CXL device at the drive or module bay arg1, slot arg2, segment arg3. arg4.
- Arguments
- arg1 = bay
- arg2 = number
- arg3 = seg
- arg4 = (Extended ID: code)
- Detailed Description
- A critical event is detected on the CXL device identified in the message.
- Recommended Response Action
- Do the following: 1) Power off the server. 2) Manually remove and reinstall the CXL device. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Critical
- Trap/EventID
- 3777
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1032
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical event is detected on the CXL device connected to PCIe segment arg1, bus arg2, device arg3, function arg4. arg5.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = function
- arg5 = (Extended ID: code)
- Detailed Description
- A critical event is detected on the CXL device connected to the PCIe bus identified in the message.
- Recommended Response Action
- Do the following: 1) Power off the server. 2) Manually remove and reinstall the CXL device. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Critical
- Trap/EventID
- 3777
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1090
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An OEM diagnostic event was detected on the CXL device at PCIe slot arg1, segment arg2. arg3.
- Arguments
- arg1 = slot
- arg2 = seg
- arg3 = (Extended ID: code)
- Detailed Description
- An OEM diagnostic event was detected on the CXL device at the location identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (CXL = CXL devices)
- Severity
- Informational
- Trap/EventID
- 3779
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1091
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An OEM diagnostic event was detected on the CXL device at drive or module bay arg1, slot arg2, segment arg3. arg4.
- Arguments
- arg1 = bay
- arg2 = number
- arg3 = seg
- arg4 = (Extended ID: code)
- Detailed Description
- An OEM diagnostic event was detected on the CXL device at the location identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (CXL = CXL devices)
- Severity
- Informational
- Trap/EventID
- 3779
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL1092
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An OEM diagnostic event was detected on the CXL device connected to PCIe segment arg1, bus arg2, device arg3, function arg4. arg5.
- Arguments
- arg1 = seg
- arg2 = bus
- arg3 = device
- arg4 = function
- arg5 = (Extended ID: code)
- Detailed Description
- An OEM diagnostic event was detected on the CXL device connected to the PCIe bus in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (CXL = CXL devices)
- Severity
- Informational
- Trap/EventID
- 3779
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL2102
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Out-of-Band management interface is unresponsive on the CXL device installed at PCIe segment arg1, slot arg2.
- Arguments
- arg1 = seg
- arg2 = slot
- Detailed Description
- The CXL device location identified in the message has an issue or does not support an Out-of-Band management interface. This results in a loss of security, thermal management, error handling, and other device management features.
- Recommended Response Action
- Verify if the device is supported by the server model in the Installation and Service Manual available on the support site. Do the following: 1) If the installed device is supported and if the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Critical
- Trap/EventID
- 3777
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
CXL2103
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Out-of-Band management interface is unresponsive on the CXL device installed at drive or module bay arg1, slot arg2, segment arg3.
- Arguments
- arg1 = bay
- arg2 = number
- arg3 = seg
- Detailed Description
- The CXL device location identified in the message has an issue or does not support an Out-of-Band management interface. This results in a loss of security, thermal management, error handling, and other device management features.
- Recommended Response Action
- Verify if the device is supported by the server model in the Installation and Service Manual available on the support site. Do the following: 1) If the installed device is supported, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (CXL = CXL devices)
- Severity
- Critical
- Trap/EventID
- 3777
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\