PowerEdge Servers Error and Event Messages Reference Guide
EPP—Extended Power Performance Event Messages
EPP001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature on chassis.
- Detailed Description
- The Extended Power Performance cannot be used unless chassis has six EPP capable PSUs, Configure the Power Redundancy Policy to Grid Redundancy & MPCM, DPSE, SBPM and Fresh Air features should be disabled.
- Recommended Response Action
- Make sure that chassis has six EPP capable PSUs, Configure the Power Redundancy Policy to Grid Redundancy & MPCM, DPSE, SBPM and Fresh Air features should be disabled. Then enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the Maximum Power Conservation Mode is enabled.
- Detailed Description
- The Extended Power Performance cannot be used because the Maximum Power Conservation Mode is enabled.
- Recommended Response Action
- Disable the Maximum Power Conservation Mode and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the Dynamic Power Supply Engagement mode is enabled.
- Detailed Description
- The Extended Power Performance cannot be used because the Dynamic Power Supply Engagement mode is enabled.
- Recommended Response Action
- Disable the Dynamic Power Supply Engagement mode and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the Server Performance Over Power Redundancy mode is enabled.
- Detailed Description
- The Extended Power Performance cannot be used because the Server Performance Over Power Redundancy mode is enabled.
- Recommended Response Action
- Disable the Server Performance Over Power Redundancy mode and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to set the Extended Power Performance (EPP) feature because the Server Based Power Management mode is enabled.
- Detailed Description
- The Extended Power Performance cannot be used because the Server Based Power Management mode is enabled.
- Recommended Response Action
- Disable the Server Based Power Management mode and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to set the Extended Power Performance (EPP) feature because the Fresh Air Configuration mode is enabled.
- Detailed Description
- The Extended Power Performance cannot be enabled because the Fresh Air Configuration mode is enabled.
- Recommended Response Action
- Disable the Fresh Air Configuration mode and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the Chassis Management Controller (CMC) firmware update is in progress.
- Detailed Description
- The Extended Power Performance cannot be used because the Chassis Management Controller (CMC) firmware update is in progress.
- Recommended Response Action
- Wait for the firmware update to complete, and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the Chassis Management Controller (CMC) failover process is in progress.
- Detailed Description
- The Extended Power Performance is cannot be used because the Chassis Management Controller (CMC) failover process is in progress.
- Recommended Response Action
- Wait for the failover process to complete, and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the Grid Redundancy feature is not available.
- Detailed Description
- The Extended Power Performance cannot be used because the Grid Redundancy feature is not available.
- Recommended Response Action
- Resolve the Grid Redundancy feature-related issue, and then retry to enable the EPP feature. For more information on the Grid Redundancy feature see Chassis Management Controller (CMC) User Guide.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the power supply unit (PSU) slot - arg1 is empty.
- Arguments
- arg1 = slot number
- Detailed Description
- The Extended Power Performance cannot be used because the power supply unit (PSU) slot identified in the message is empty.
- Recommended Response Action
- Install an EPP-capable PSU in the empty slot, and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the power supply unit (PSU) slot - arg1 has no input power.
- Arguments
- arg1 = slot number
- Detailed Description
- The Extended Power Performance cannot be used because the power supply unit (PSU) slot identified in the message has no power supply.
- Recommended Response Action
- Make sure that the PSU in the PSU slot has input power, and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the power supply unit (PSU) slot - arg1 has no output power.
- Arguments
- arg1 = slot number
- Detailed Description
- The Extended Power Performance cannot be used because the power supply unit (PSU) slot identified in the message has no output power.
- Recommended Response Action
- Make sure that the PSU in the PSU slot has no issue in the output power, and then retry to enable the EPP feature. To check the health status of the PSU identified in the message using the RACADM CLI utility, enter the following command: "racadm getpbinfo". If the PSU identified in the message is showing no output power, contact your service provider.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the power rating of power supply unit (PSU) slot - arg1 is less than 3000W.
- Arguments
- arg1 = slot number
- Detailed Description
- The Extended Power Performance cannot be used because the power rating of PSU identified in the slot is less than 3000W.
- Recommended Response Action
- Make sure that there are at least six PSUs in the chassis and each PSU must be of 3000W capacity, and then retry to enable the EPP feature.
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the Redundancy Policy is not set to Grid Redundancy.
- Detailed Description
- The Extended Power Performance is cannot be used because the Redundancy Policy is not set to Grid Redundancy.
- Recommended Response Action
- Configure the Power Redundancy Policy to Grid Redundancy and retry to enable the EPP feature. To configure the Power Redundancy Policy using the RACADM CLI utility, enter the following command: "racadm config -g cfgChassisPower -o cfgChassisRedundancyPolicy 1".
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
EPP015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to use the Extended Power Performance (EPP) feature because the System Input Power Cap is set to less than or equal to 13300W (45381 BTU/h).
- Detailed Description
- The Extended Power Performance cannot be used because the System Input Power Cap is set to less than or equal to 13300W (45381 BTU/h).
- Recommended Response Action
- Set the Chassis Power Cap to greater than 13300W (45381 BTU/h), and then retry to use the EPP feature. To set the Chassis Power Cap using the RACADM CLI utility, enter the following command: "racadm config -g cfgChassisPower -o cfgChassisDefaultPowerCapUpperBound 13301".
- Category
- System Health (EPP = Extended Power Performance)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
Please provide ratings (1-5 stars).