PowerEdge Servers Error and Event Messages Reference Guide
IOV—IO Virtualization Event Messages
IOV000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Successfully completed the operation.
- Detailed Description
- This operation was successful.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The operation contains an invalid request or argument.
- Detailed Description
- The operation or operation parameter sent to the Chassis Manager is invalid or not supported.
- Recommended Response Action
- Contact technical support. Refer to Chassis Manager product documentation to determine the contact method for the service provider.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to create or allocate the required resources.
- Detailed Description
- CMC could not successfully allocate resources because of the following reasons: 1) The chassis manager is unable to allocate required resources. 2) The chassis manager or chassis infrastructure firmware is rolled back to an earlier version. 3) There is an issue with the internal communications between chassis components.
- Recommended Response Action
- Make sure the firmware for the various chassis components are compatible with each other. If this is the case, do the following: 1) Turn off the chassis, by pressing the chassis Power Button, 2) run the following CMC RACADM command "racadm racresetcfg". If the problem persists, contact your technical service provider.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to manage the device located in the PCIe slot specified in the operation.
- Detailed Description
- A PCIe device error was detected that does not allow the assignment, unassignment, or the turning off of the device. The errors can be caused by incorrect PCIe device installation or installation of an unsupported PCIe adapter card. For a list of supported PCIe adapter cards contact your service provider.
- Recommended Response Action
- Make sure that supported adapters are used and installed correctly in the PCIe slots.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to turn on PCIe adapter.
- Detailed Description
- The chassis manager is unable to turn on the PCIe device because of one of the following reasons: 1) PCIe device is not supported, 2) The device is not properly inserted in the slot, 3) The device is not functioning properly, or 4) The device power requirements exceed the power available for the slot.
- Recommended Response Action
- Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For a list of supported devices, contact the service provider.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chassis Management Controller (CMC) is not ready to run commands.
- Detailed Description
- The Chassis Management Controller is not ready to run commands because the chassis must be turned on.
- Recommended Response Action
- Turn on chassis and retry the command.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Incorrect Chassis Infrastructure Mainboard firmware version.
- Detailed Description
- The Chassis Infrastructure Mainboard firmware is not at the correct version.
- Recommended Response Action
- Run the command "racadm fwupdate -g -u -a <TFTP server IP Address> -d mainboard.bin -m main_board" to upload the latest firmware version to the Chassis Infrastructure Mainboard.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chassis Management Controller (CMC) is unable to allocate power to one or more PCIe adapters in the Chassis Infrastructure component.
- Detailed Description
- For each adapter assigned to a server, power is allocated when the server is turned on. If the available power is less than the required power, the Chassis Management Controller (CMC) will not power on the adapters associated with the server.
- Recommended Response Action
- To release the required power, turn off one or more servers by pressing the Power Button on the individual server units.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chassis Management Controller (CMC) is unable to put PCIe subsystem into factory default mode.
- Detailed Description
- The Chassis Management Controller (CMC) was unable to reset the PCIe subsystem into factory default mode.
- Recommended Response Action
- Turn off the chassis, turn on the chassis, and then retry the operation.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chassis Management Controller (CMC) is unable to reset to factory default or pre-factory default settings.
- Detailed Description
- The Chassis Management Controller (CMC) runs this function only when the chassis is turned off.
- Recommended Response Action
- Turn off the chassis and retry the operation.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to assign the PCIe slot(s) because a license is required to assign more than two PCIe slots to a server.
- Detailed Description
- Unable to assign the PCIe slots because a license is required to assign more than two PCIe slots to a server. Non-licensed systems are allowed only two slots per server.
- Recommended Response Action
- Import a license that allows assignments of more than two PCIe slots per server. For more information about licenses, contact your service provider.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to assign or unassign PCIe slot(s) or virtual adapter (VA) because all affected servers must be turned off.
- Detailed Description
- All servers that PCIe slots or virtual adapter (VA) will be assigned-to and unassigned-from must be turned off before an assign or unassign operation can be performed.
- Recommended Response Action
- Turn off all servers that the PCIe slots or virtual adapter (VA) will be assigned-to and unassigned-from, and then retry the operation.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to assign a virtual adapter (VA) to a non-default server because a license is required.
- Detailed Description
- By default, the non-licensed system assigns virtual adapters (VA) 1-4 to servers 1-4 respectively.
- Recommended Response Action
- Import a license which enables the assignment of a PERC virtual adapter (VA) to any server. For more information about licenses, contact your service provider.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to assign a virtual adapter (VA) to a server that is already assigned a VA, because a server may be assigned only one VA.
- Detailed Description
- Unable to assign a virtual adapter (VA) to a server that is already assigned a VA, because a server may be assigned only one VA.
- Recommended Response Action
- Unassign the servers current virtual adapter (VA) and retry the operation. To unassign the VA using RACADM, run the following command "racadm setpciecfg".
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The external shared storage device is not ready because the initialization process is still incomplete.
- Detailed Description
- The external shared storage device is not ready because the initialization process is still incomplete.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to map/un-map or turn on the external shared adapter because the firmware version of Chassis Management Controller (CMC) Chassis Infrastructure Mainboard is not the latest version supporting the adapter.
- Detailed Description
- The external shared adapter cannot be turned on until the Chassis Infrastructure firmware is updated to the latest version supporting the shared adapter.
- Recommended Response Action
- Remove the adapter or update the Chassis Infrastructure firmware and then retry the operation. Using the Chassis Management Controller (CMC) RACADM, run the command "racadm fwupdate -g -u -a <TFTP server IP Address> -d mainboard.bin -m main_board" to upload the latest firmware version to the Chassis Infrastructure Mainboard.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Only the virtual adapters (VA) of a shared adapter may be assigned to or unassigned from a server.
- Detailed Description
- The shared adapter may not be assigned to or unassigned from a blade-server. Only the virtual adapters (VA) of a shared adapter may be assigned to or unassigned from a server.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—
- Applicable Event or Alert Types
- CMC—Filter Visibility
IOV1001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The requested operation was successfully executed.
- Detailed Description
- The requested operation was successfully executed.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
IOV1002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The operation was not successful.
- Detailed Description
- The operation did not complete successfully due to an exception from the instrumentation layer.
- Recommended Response Action
- Retry the operation. If the issue persists, reset CMC and retry the operation when the CMC has completed restarting. The CMC may take 2 to 3 minutes to complete restarting.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
IOV1003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Missing required parameter arg1.
- Arguments
- arg1 = parameter name
- Detailed Description
- One or more parameters identified in the message required for the method are missing.
- Recommended Response Action
- Refer to the DCIM Chassis PCI Management Profile document and provide the required parameter.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
IOV1004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Too many slots provided as parameters to Assign and UnAssign Servers methods.
- Detailed Description
- The parameters for the method identified in the message are not passed correctly.
- Recommended Response Action
- Refer to the DCIM Chassis PCI Management Profile document and provide the required parameters.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
IOV1005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid slot FQDD arg1.
- Arguments
- arg1 = FQDD value
- Detailed Description
- The FQDD (Fully Qualified Device Descriptor) entered for the operation does not map to any instance of the DCIM_ChassisPCISlot class.
- Recommended Response Action
- Perform the Enumerate operation on the DCIM_ChassisPCISlot class to determine the correct FQDD value for the required slot. Retry the operation with the correct FQDD value.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
IOV1006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid PCI slot or Server slot.
- Detailed Description
- The PCI slot or Server slot FQDD (Fully Qualified Device Descriptor) values entered for the operation are not valid.
- Recommended Response Action
- Perform the Enumerate operation on the DCIM_ChassisPCISlot class and DCIM_BladeServerView class to get the correct FQDD values for the PCIe slot and Server slot. Retry the operation with the correct FQDD values.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
IOV1007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to assign a PCIe slot.
- Detailed Description
- The IOV slot management subsystem detected an error which may prevent the physical assignment/unassignment or turning off of a PCIe slot. The errors can be caused by PCIe training timeouts, false hot plug signals,or installation of an unsupported PCIe adapter card. For a list of supported PCIe adapter cards contact your service provider.
- Recommended Response Action
- Insert only supported adapter cards into system PCIe slots and make sure they are fully inserted. Retry the operation.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
IOV1008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Invalid Virtual Adapter FQDD arg1.
- Arguments
- arg1 = FQDD value
- Detailed Description
- The FQDD (Fully Qualified Device Descriptor) value entered for the operation does not map to any DCIM_ChassisVAView class instance representing Virtual Adapters.
- Recommended Response Action
- Perform an Enumerate operation on the DCIM_ChassisVAView class to get the correct FQDD for the Virtual Adapter. Retry the operation with the correct FQDD value.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
IOV1009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Mismatch in Slot or Virtual Adapter FQDD and Server Slot FQDD count.
- Detailed Description
- The FQDD pairs identified in the messages do not match in the required method input parameters.
- Recommended Response Action
- Provide a valid pair of FQDDs. Please refer to the DCIM Chassis PCI Management Profile document for the required parameter definitions.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
IOV101
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCIe adapter arg1 is inserted in arg2 arg3.
- Arguments
- arg1 = device name
- arg2 = slot type
- arg3 = slot number
- Detailed Description
- The Chassis Management Controller (CMC) detected the insertion of an adapter in the slot identified in the message.
- Recommended Response Action
- If the adapter in slot identified in the message is mapped to a server, the server must be turned off then back on before server can access adapter. If the adapter in slot is a shared adapter and any server is on then the entire chassis must be turned off and turned on for the server(s) to gain access to the installed shared adapter.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, OS Log, Chassis Event Proxy*
IOV102
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCIe adapter arg1 is removed from arg2 arg3.
- Arguments
- arg1 = device name
- arg2 = slot type
- arg3 = slot number
- Detailed Description
- The Chassis Management Controller (CMC) detected the removal of an adapter card from the slot identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, OS Log, Chassis Event Proxy*
IOV103
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A PCIe adapter arg1 in arg2arg3 is replaced by PCIe adapter arg4.
- Arguments
- arg1 = device name
- arg2 = slot type
- arg3 = slot number
- arg4 = device name
- Detailed Description
- The Chassis Management Controller (CMC) detected the replacement of an adapter in the slot identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV104
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Chassis Management Controller (CMC) is unable to allocate arg1 Watt for server-arg2 PCIe adapters.
- Arguments
- arg1 = number of Watt
- arg2 = server slot number
- Detailed Description
- For each adapter assigned to a server, power is allocated when the server is turned on. If the available power is less than the required power, the Chassis Management Controller (CMC) will not power on the adapters associated with the server.
- Recommended Response Action
- Using the Chassis Management Controller (CMC) RACADM command line interface, run the command "racadm config -g cfgChassisPower -o cfgChassisPowerCap <Power cap>" to increase the power cap or add an additional power supply.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Warning
- Trap/EventID
- 2554
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV105
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to manage PCIE adapter arg1 located in arg2 arg3.
- Arguments
- arg1 = device name
- arg2 = slot type
- arg3 = slot number
- Detailed Description
- An error by the Chassis Infrastructure slot management detected an error which may prevent the physical assignment/unassignment or power off of a slot. The errors may be caused by PCIE training timeouts, false hot plug signals, or installation of an unsupported PCIe adapter card. For a list of supported PCIe adapter cards contact your service provider.
- Recommended Response Action
- Make sure that supported adapters are used and installed correctly in the PCIe slot.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Warning
- Trap/EventID
- 2554
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV106
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to power on PCIe adapter arg1 in arg2 arg3.
- Arguments
- arg1 = device name
- arg2 = slot type
- arg3 = slot number
- Detailed Description
- The Chassis Management Controller (CMC) is unable to power on adapter. Possible reasons for power failures are: 1) Adapter not an approved adapter. 2) Adapter not fully inserted in the slot 3) Auxiliary power cable not connected (applicable to slot 1 - 3 only). 4) Adapter is damaged.
- Recommended Response Action
- Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For a list of supported devices, If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Warning
- Trap/EventID
- 2554
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV107
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- PCIe adapter arg1 in slot arg2 was removed while powered on.
- Arguments
- arg1 = device dame
- arg2 = slot number
- Detailed Description
- The Chassis Management Controller (CMC) has detected the removal of a PCIe adapter card while it was powered on.
- Recommended Response Action
- Power down the affected server(s) and then power on the server(s). Note: OS reboot only will not correct this issue.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Critical
- Trap/EventID
- 2553
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV108
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Power fault detected on PCIE adapter arg1 in arg2 arg3.
- Arguments
- arg1 = device name
- arg2 = slot type
- arg3 = slot number
- Detailed Description
- The Chassis Management Controller (CMC) detected a power fault in an adapter after the adapter was powered on. A power fault may be caused by a damaged adapter or the adapter power requirements exceed the maximum power limits of the slot.
- Recommended Response Action
- Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For a list of supported devices, If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Warning
- Trap/EventID
- 2554
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV109
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An error condition associated with the PCIe slot is cleared.
- Detailed Description
- An error condition associated with the PCIe slot is cleared.
- Recommended Response Action
- No response action is required.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 2555
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*
- Applicable Event or Alert Types
- CMC—Filter Visibility, LCD, Chassis Event Proxy*
IOV110
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Successfully updated Chassis Infrastructure firmware.
- Detailed Description
- Successfully updated Chassis Infrastructure firmware.
- Recommended Response Action
- No response action is required.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, LC Log*, Chassis Event Proxy*
IOV111
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to update Chassis Infrastructure firmware.
- Detailed Description
- Unable to successfully update Chassis Infrastructure firmware.
- Recommended Response Action
- Refer to the release notes of the Mainboard update package for recommended action. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Critical
- Trap/EventID
- 2553
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
IOV112
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chassis Infrastructure firmware is not valid.
- Detailed Description
- Chassis infrastructure firmware is not valid and must be reinstalled.
- Recommended Response Action
- Update the Chassis Infrastructure firmware. Using Chassis Management Controller (CMC) RACADM, run the command "racadm fwupdate -g -u -a <TFTP server IP Address> -d mainboard.bin -m main_board" to upload the latest firmware version to the Chassis Infrastructure Mainboard.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Critical
- Trap/EventID
- 2553
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
IOV113
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Chassis Infrastructure firmware re-installation is successful.
- Detailed Description
- Chassis Infrastructure firmware re-installation is successful.
- Recommended Response Action
- No response action is required.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, LC Log*, LCD, Chassis Event Proxy*
IOV114
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 arg2 assigned to server-arg3.
- Arguments
- arg1 = "PCIE Slot" or "PERC VA"
- arg2 = slot number or VA number
- arg3 = server number
- Detailed Description
- The PCIE Slot or PERC Virtual Adapter (VA) identified in the message has been assigned to the server identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV115
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to allocate arg1 WATTS for discovery of PCIE adapters.
- Arguments
- arg1 = number of watts
- Detailed Description
- The discovery process for PCIE adapters was unable to allocate the power required to power on the PCIE adapters.
- Recommended Response Action
- Using the Chassis Management Controller (CMC) RACADM command line interface, run the command "racadm config -g cfgChassisPower -o cfgChassisPowerCap <Power cap>" to increase the power cap or add an additional power supply.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Trap/EventID
- 10746
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, OS Log, Chassis Event Proxy*
IOV116
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- PCIE AUX power cable arg1.was disconnected while powered on.
- Arguments
- arg1 = cable number
- Detailed Description
- The Chassis Management Controller (CMC) detected a power fault in an PCIE AUX power cable after the adapter was powered on. A power fault may be caused by a loose cable connection to the adapter or between the cable and the AUX cable harness.
- Recommended Response Action
- Make sure AUX power cable identified in the message is fully plugged into the adapter and the AUX cable harness.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Warning
- Trap/EventID
- 2554
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV117
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 arg2 was unassigned/unmapped from server-arg3.
- Arguments
- arg1 = "PCIE Slot" or "PERC VA"
- arg2 = slot number or VA number
- arg3 = server number
- Detailed Description
- The PCIE Slot or PERC Virtual Adapter(VA) identified in the message has been unassigned/unmapped from the server identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV118
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Fabric arg1 is down.
- Arguments
- arg1 = fabric ID
- Detailed Description
- The Fabric identified in the message is not up and a chassis power cycle is required.
- Recommended Response Action
- Power cycle the chassis. Using the Chassis Management Controller (CMC) RACADM command line interface, run the command "racadm chassisaction powercycle".
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Critical
- Trap/EventID
- 2553
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV119
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- PCIe ride-through mode is disabled.
- Detailed Description
- The Chassis Management Controller (CMC) has disabled PCIe ride-through mode. PCIe adapters that are turned on and in "ride-through" mode are immediately turned off.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, OS Log, Chassis Event Proxy*
IOV120
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- PCIe ride-through mode is enabled.
- Detailed Description
- The Chassis Management Controller (CMC) has enabled PCIe ride-through mode. PCIe adapters will remain turned on for the number of seconds specified by the ride-through timeout value after the server they are assigned to is turned off.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, OS Log, Chassis Event Proxy*
IOV121
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- PCIe ride-through time out has changed from arg1 to arg2 seconds.
- Arguments
- arg1 = seconds
- arg2 = seconds
- Detailed Description
- The Chassis Management Controller (CMC) has changed the PCIe ride-through timeout to the value identified in the message. PCIe adapters will remain turned on for the number of seconds specified by the ride-through timeout value after the server they are assigned to is turned off. Note: A value of zero equals infinite number of seconds.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, OS Log, Chassis Event Proxy*
IOV122
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 arg2 is mapped/assigned to extension of server slot arg3.
- Arguments
- arg1 = "PCIE Slot" or "PERC VA"
- arg2 = slot number or VA number
- arg3 = server number
- Detailed Description
- The PCIE Slot or PERC Virtual Adapter (VA) identified in the message has been assigned to the extension of the server slot identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, OS Log, Chassis Event Proxy*
IOV123
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 arg2 is unassigned/unmapped from extended server slot arg3.
- Arguments
- arg1 = "PCIE Slot" or "PERC VA"
- arg2 = slot number or VA number
- arg3 = server number
- Detailed Description
- The PCIE Slot or PERC Virtual Adapter(VA) identified in the message has been unassigned/unmapped from the extension of the server slot identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Informational
- Trap/EventID
- 10747
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, OS Log, Chassis Event Proxy*
IOV124
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The PCIe shared adapter in slot arg1 is not supported because the firmware version of the Chassis Infrastructure Mainboard is not the latest.
- Arguments
- arg1 = slot number
- Detailed Description
- The PCIe shared adapter in slot identified in the message is not supported because the firmware version of Chassis Management Controller (CMC) Chassis Infrastructure Mainboard is not the latest.
- Recommended Response Action
- Remove the adapter or update the Chassis Infrastructure firmware and then retry the operation. Using Chassis Management Controller (CMC) RACADM, run the command "racadm fwupdate -g -u -a <TFTP server IP Address> -d mainboard.bin -m main_board" to upload the latest firmware version to the Chassis Infrastructure Mainboard.
- Category
- Configuration (IOV = IO Virtualization)
- Severity
- Warning
- Trap/EventID
- 10746
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, OS Log, Chassis Event Proxy*
IOV2008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Chassis Management Controller (CMC) is unable to communicate with the PCIe subsystem.
- Detailed Description
- The Chassis Management Controller (CMC) could not successfully connect to the PCIe subsystem.
- Recommended Response Action
- Do the following: 1) Perform an AC Power Cycle operation on the Chassis by disconnecting the chassis from AC power, wait for 30 seconds, and then reconnect AC power. 2) Turn on at least one server. Using the Chassis Management Controller (CMC) web interface, select Server Overview->Power->Control and select the Power On Server option. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (IOV = IO Virtualization)
- Severity
- Critical
- Trap/EventID
- 2553
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Filter Visibility, SNMP Alert*, Email Alert*, Remote System Log*, LC Log*, LCD, Chassis Event Proxy*
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\