MEM—Memory Event Messages

MEM0000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Persistent correctable memory errors detected on a memory device at location(s) arg1.
Arguments
  • arg1 = location
Detailed Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Multi-bit memory errors are detected on the memory device at location(s) arg1. Immediately replace the DIMM.
Arguments
  • arg1 = location
Detailed Description
The memory has an uncorrectable error. System performance may be degraded and the operating system and/or applications may fail as a result of this.
Recommended Response Action
Immediately replace the DIMM.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Multi-bit memory error on <location>. Reseat memory
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Parity memory errors detected on a memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Stuck bit memory error detected on a memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is disabled.
Arguments
  • arg1 = location
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Recommended Response Action
Re-install the memory component. Review product documentation for supported memory configurations. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Persistent correctable memory error limit reached for a memory device at location(s) arg1.
Arguments
  • arg1 = location
Detailed Description
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Persistent correctable memory error limit reached for <location>. Reseat memory.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is present.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unsupported memory configuration; check memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Recommended Response Action
Review product documentation for supported memory configurations.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Unsupported memory configuration. Check memory <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is spare memory.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is throttled.
Arguments
  • arg1 = location
Detailed Description
System performance is degraded.
Recommended Response Action
If unexpected, review system logs for power or thermal exceptions.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is overheating.
Arguments
  • arg1 = location
Detailed Description
System performance is degraded.
Recommended Response Action
If unexpected, review system logs for power or thermal exceptions.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Memory device <location> is over heating. Check fans
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location(s) arg1 is operating correctly.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is enabled.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM0021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Persistent correctable memory error limit reset for a memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0022

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is absent.
Arguments
  • arg1 = location
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Recommended Response Action
If unexpected, check presence, then re-install.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0024

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is no longer spare memory.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0025

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
DDFS is disabled due to a problem with the NVRAM subsystem.
Detailed Description
An issue is detected with an NVRAM card, resulting in disablement of DDFS.
Recommended Response Action
Contact your service provider / tech support to resolve the issue.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

MEM0026

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware fault was detected with an NVRAM card and it may need to be replaced.
Detailed Description
One or more issues or faults were detected with an NVRAM card and the card may need to be replaced.
Recommended Response Action
Contact your service provider / tech support to resolve the issue.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

MEM0600

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device was added at location arg1.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM0601

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device is removed from location arg1.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM0700

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The persistent correctable memory error rate is at normal levels for a memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0701

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Correctable memory errors detected for arg1.
Arguments
  • arg1 = location
Detailed Description
Memory is operational. System detected and corrected memory errors.
Recommended Response Action
Reboot the system to enable potential memory self-healing. Ensure BIOS is up to date. If problem persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
LCD Message
Correctable memory errors detected for <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0702

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Correctable memory errors detected for arg1.
Arguments
  • arg1 = location
Detailed Description
Memory is operational. System detected and corrected memory errors.
Recommended Response Action
Reboot the system to enable potential memory self-healing. Ensure BIOS is up to date. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Correctable memory errors detected for <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0802

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The memory health monitor feature has detected a degradation in the DIMM installed in arg1. Reboot system to initiate self-heal process.
Arguments
  • arg1 = location
Detailed Description
The memory health monitor feature has detected a degradation in the DIMM installed in the slot identified in the message. Reboot system to initiate self-heal process.
Recommended Response Action
The system memory health must be improved by initiating the self-heal process. To start the process, restart the system.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Reboot system to initiate self-healing at DIMM <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0804

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The self-heal operation successfully completed at DIMM arg1.
Arguments
  • arg1 = location
Detailed Description
The self-heal operation successfully completed on the memory module.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM0805

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the self-heal operation of the memory in the DIMM installed in arg1 because of internal issues. Replace the DIMM during the next planned service operation.
Arguments
  • arg1 = location
Detailed Description
The self-heal operation of the memory in the DIMM installed in the location identified in the message cannot be completed because of internal issues.
Recommended Response Action
Replace the DIMM during the next planned service operation.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Self-healing failed at DIMM <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 transition to a running state.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM1001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 failed to transition to a running state.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
LCD Message
Memory device <location> failed to transition to a running state. Reseat memory
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM1002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is in test.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 failed to transition to in test.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is powered off.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 failed to power off.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
Re-attempt memory removal process.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is online.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 failed to transition to online.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
Re-attempt memory removal process.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is offline.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 failed to transition to offline.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
Re-attempt memory removal process.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is off-duty.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is on-duty.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is in a degraded state.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is in a full state.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is in a power save state.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is in a power active state.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is not installed correctly.
Arguments
  • arg1 = location
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Memory <location> is not installed correctly. Re-install
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1017

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device at location arg1 is installed correctly.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1200

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory RAID is redundant.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1201

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory RAID redundancy is lost. Check memory device at location(s) arg1.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Memory RAID lost on <location>. Power cycle system
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1202

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory RAID redundancy is degraded. Check memory device at location(s) arg1.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1203

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory is not redundant.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1204

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory mirror is redundant.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1205

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory mirror redundancy is lost. Check memory device at location(s) arg1.
Arguments
  • arg1 = location
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended Response Action
Review system logs for memory exceptions. Re-install memory at location <location>.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Memory mirror lost on <location>. Power cycle system
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1206

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory mirror redundancy is degraded. Check memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended Response Action
Review system logs for memory exceptions. Re-install memory at location <location>.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1207

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory spare is redundant.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1208

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory spare redundancy is lost. Check memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
The assigned spare is no longer available.
Recommended Response Action
Review system logs for memory exceptions. Re-install memory at location <location>.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Memory spared lost on <location>. Power cycle system
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1209

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory spare redundancy is degraded. Check memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1210

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory is redundant.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM1212

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory redundancy is lost.
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended Response Action
Review system logs for memory exceptions. Re-install memory at location <location>.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM1214

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory redundancy is degraded.
Detailed Description
The memory may not be seated correctly, misconfigured, or has failed.
Recommended Response Action
Review system logs for memory exceptions. Re-install memory at location <location>.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM5100

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An operation has completed successfully in the memory device at arg1. The server and device is operating normally. Extended ID: arg2.
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
An operation has completed successfully in the memory device at the location identified in the message.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM5101

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic event occurred in the memory device at arg1. Check the device and system configuration. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic event occurred in the memory device at location identified in the message. The device may be operating in a degraded state. Checking the device and system configuration is recommended for remediation.
Recommended Response Action
Make sure that the server and device configuration is as per the recommendations in the respective PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM5102

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic event occurred in the memory device at arg1. Reseat the device. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic event occurred in the memory device at location identified in the message. Reseating the device is recommended for remediation. Contact technical support if problem persists.
Recommended Response Action
Manually reseat the memory device. For instructions about reseating, see the respective servers PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM5103

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic event occurred in the memory device at arg1. Perform a warm reboot. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic event occurred in the memory device at location identified in the message. Performing a warm reboot is recommended for remediation. System will attempt to perform self-healing or self-correction.
Recommended Response Action
Perform a warm reboot to allow server to attempt self-healing or self-correction. If a warm reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM5104

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic event occurred in the memory device at arg1. Perform a cold reboot. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic event occurred in the memory device at location identified in the message. Performing a cold reboot is recommended for remediation. System will attempt to perform self-healing or self-correction.
Recommended Response Action
Perform a cold reboot to allow server to attempt self-healing or self-correction. If a cold reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM5107

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic event occurred in the memory device at arg1. Retry operation. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic event occurred in the memory device at location identified in the message. The attempted operation on this device has failed. Retry operation.
Recommended Response Action
Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM5109

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic event occurred in the memory device at arg1. The device is cryptographically locked. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic event occurred in the memory device at location identified in the message. The device is cryptographically locked. Attempt to re-enter the encryption passphrase to unlock or Secure Erase the device to cryptographically erase all data and restore unrestricted access to the device.
Recommended Response Action
Do one of the following: 1) Try to unlock the device by entering the encryption passphrase. 2) Perform a Secure Erase operation on the device to cryptographically erase all data, and then restore an unrestricted access to the device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM5199

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unknown diagnostic event occurred in the memory device at arg1. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
An unknown diagnostic event occurred in the memory device at location identified in the message. iDRAC firmware must be updated to properly decode this event.
Recommended Response Action
Update iDRAC firmware to the latest version available. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM6000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device monitoring is disabled.
Detailed Description
The memory module may not be correctly seated, wrongly configured, or has failed.
Recommended Response Action
Review the Embedded System Management (ESM) Log for memory exceptions. Re-install the memory modules.
Category
System Health (MEM = Memory)
Severity
Informational
OMSA Event ID
5400
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

MEM6001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device status is unknown. Memory device location: arg1, Possible memory module event cause: arg2.
Arguments
  • arg1 = location
  • arg2 = cause
Detailed Description
The memory module may not be correctly seated, wrongly configured, or has failed.
Recommended Response Action
Review the Embedded System Management (ESM) Log for memory exceptions. Re-install the memory modules at the identified location .
Category
System Health (MEM = Memory)
Severity
Warning
OMSA Event ID
5401
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

MEM6002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device status is normal. Memory device location: arg1.
Arguments
  • arg1 = location
Detailed Description
The memory device identified in the message has returned to a normal state.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
OMSA Event ID
5402
OMSA Trap ID
5402
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

MEM6003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device status is non-critical. Memory device location: arg1, Possible memory module event cause: arg2.
Arguments
  • arg1 = location
  • arg2 = cause
Detailed Description
The memory module may not be correctly seated, wrongly configured, or has failed.
Recommended Response Action
Review the Embedded System Management (ESM) Log for memory exceptions. Re-install the memory modules at the identified location .
Category
System Health (MEM = Memory)
Severity
Warning
OMSA Event ID
5403
OMSA Trap ID
5403
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

MEM6004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device status is critical. Memory device location: arg1, Possible memory module event cause: arg2.
Arguments
  • arg1 = location
  • arg2 = cause
Detailed Description
The memory module may not be correctly seated, wrongly configured, or has failed.
Recommended Response Action
Review the Embedded System Management (ESM) Log for memory exceptions. Re-install the memory modules at the identified location .
Category
System Health (MEM = Memory)
Severity
Critical
OMSA Event ID
5404
OMSA Trap ID
5404
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

MEM6005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory device has failed. Memory device location: arg1, Possible memory module event cause: arg2.
Arguments
  • arg1 = location
  • arg2 = cause
Detailed Description
The memory module failed because of an irrecoverable error.
Recommended Response Action
Review the Embedded System Management (ESM) Log for memory exceptions. Remove the old memory module and install a new memory module at the identified location .
Category
System Health (MEM = Memory)
Severity
Critical
OMSA Event ID
5405
OMSA Trap ID
5405
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

MEM6101

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic warning event occurred in the memory device at arg1. Check the device and system configuration. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic warning event occurred in the memory device at location identified in the message. The device may be operating in a degraded state. Checking the device and system configuration is recommended for remediation.
Recommended Response Action
Make sure that the server and device configuration is as per the recommendations in the respective PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Warning event at <location>. Check memory config.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM6102

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic warning event occurred in the memory device with Serial No: arg1 and Part No: arg2 at arg3. Reseat the device (Extended ID: arg4).
Arguments
  • arg1 = serialNo
  • arg2 = partNo
  • arg3 = location
  • arg4 = code
Detailed Description
A diagnostic warning event occurred in the memory device at location identified in the message. Reseating the device is recommended for remediation. Contact technical support if problem persists.
Recommended Response Action
Manually reseat the memory device. For instructions about reseating, see the respective servers PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Warning event at <location>. Reseat device.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM6104

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic warning event occurred in the memory device with Serial No: arg1 and Part No: arg2 at arg3. Perform a cold reboot(Extended ID: arg4).
Arguments
  • arg1 = serialNo
  • arg2 = partNo
  • arg3 = location
  • arg4 = code
Detailed Description
A diagnostic warning event occurred in the memory device at location identified in the message. Performing a cold reboot is recommended for remediation. System will attempt to perform self-healing or self-correction.
Recommended Response Action
Perform a cold reboot to allow server to attempt self-healing or self-correction. If a cold reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Warning event at <location>. Cold reboot system.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM6106

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic warning event occurred in the memory device at arg1 (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic warning event occurred in the memory device at location identified in the message. System will automatically attempt to perform self-healing or self-correction at next opportunity.
Recommended Response Action
Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Warning event at <location>. Contact service if persistent.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM6107

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic warning event occurred in the memory device at arg1. Retry operation. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic warning event occurred in the memory device at location identified in the message. The attempted operation on this device has failed. Retry operation.
Recommended Response Action
Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Warning event at <location>. Retry operation.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM6110

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic warning event occurred in the memory device at arg1. Update device firmware. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic warning event occurred in the memory device at location identified in the message. Update the firmware for the memory device to enable new features or address known issues.
Recommended Response Action
Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Warning event at <location>. Update device firmware.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM6114

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A diagnostic warning event occurred in the memory device at arg1 (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A diagnostic warning event occurred in the memory device at location identified in the message.
Recommended Response Action
If the issue persists,Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Warning event at <location>. Contact service provider.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM6199

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unknown diagnostic warning event occurred in the memory device at arg1. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
An unknown diagnostic warning event occurred in the memory device at location identified in the message. iDRAC firmware must be updated to properly decode this event.
Recommended Response Action
Update iDRAC firmware to the latest version available. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Unknown warning event at <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The memory riser mismatch was corrected.
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A hardware mismatch detected for memory riser.
Detailed Description
No detailed description available.
Recommended Response Action
Review product documentation for proper memory riser installation and configuration.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Memory riser mismatch detected. Check memory riser
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7101

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A critical diagnostic event occurred in the memory device at arg1. Check the device and system configuration. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A critical diagnostic event occurred in the memory device at location identified in the message. The device may be operating in a degraded state. Checking the device and system configuration is recommended for remediation.
Recommended Response Action
Make sure that the server and device configuration is as per the recommendations in the respective PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Critical event at <location>. Check memory config.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7102

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A critical diagnostic event occurred in the memory device at arg1. Reseat the device. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A critical diagnostic event occurred in the memory device at location identified in the message. Reseating the device is recommended for remediation. Contact technical support if problem persists.
Recommended Response Action
Manually reseat the memory device. For instructions about reseating, see the respective servers PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Critical event at <location>. Reseat device.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7104

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A critical diagnostic event occurred in the memory device at arg1. Perform a cold reboot. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A critical diagnostic event occurred in the memory device at location identified in the message. Performing a cold reboot is recommended for remediation. System will attempt to perform self-healing or self-correction.
Recommended Response Action
Perform a cold reboot to allow server to attempt self-healing or self-correction. If a cold reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Critical event at <location>. Cold reboot system.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7107

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A critical diagnostic event occurred in the memory device at arg1. Retry operation. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A critical diagnostic event occurred in the memory device at location identified in the message. The attempted operation on this device has failed. Retry operation.
Recommended Response Action
Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Critical event at <location>. Retry operation.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7108

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A critical diagnostic event occurred in the memory device at arg1. Sanitize the device. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A critical diagnostic event occurred in the memory device at location identified in the message. The memory device has detected an error during startup that either cannot be recovered or has been moved from another server, which has resulted in a unusable configuration data.
Recommended Response Action
To recover the device, sanitize the memory device. Sanitizing the device will destroy all data on the device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Critical event at <location>. Sanitize device.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7110

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A critical diagnostic event occurred in the memory device at arg1. Update device firmware. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
A critical diagnostic event occurred in the memory device at location identified in the message. Update the firmware for the memory device to enable new features or address known issues.
Recommended Response Action
Update the memory device firmware to enable new features and resolve any known issues. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Critical event at <location>. Update device firmware.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7114

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A critical diagnostic event occurred in the memory device with Serial No: arg1 and Part No: arg2 at arg3 (Extended ID: arg4).
Arguments
  • arg1 = serialNo
  • arg2 = partNo
  • arg3 = location
  • arg4 = code
Detailed Description
A critical diagnostic event occurred in the memory device at location identified in the message.
Recommended Response Action
If the issue persists,Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Critical event at <location>. Contact service provider.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM7199

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An unknown critical diagnostic event occurred in the memory device at arg1. (Extended ID: arg2).
Arguments
  • arg1 = location
  • arg2 = code
Detailed Description
An unknown critical diagnostic event occurred in the memory device at location identified in the message. iDRAC firmware must be updated to properly decode this event.
Recommended Response Action
Update iDRAC firmware to the latest version available. If the issue persists,Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Unknown critical event at <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM8000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Correctable memory error logging disabled for a memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
Errors are being corrected but predicitive failure algorith is unable to run at optimal conditions. please update BIOS to fix issue.
Recommended Response Action
Please update to latest BIOS an update was added which aliviates this issue.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
SBE log disabled on <location>. Reseat memory
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM8001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Persistent correctable memory error logging enabled for a memory device at location arg1.
Arguments
  • arg1 = location
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM8500

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Low memory condition detected.
Detailed Description
A low memory condition was detected. If this condition continues, a failover or a reset may occur. If multiple resets occur, contact your service provider.
Recommended Response Action
If multiple resets occur, If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Audit (MEM = Memory)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM8501

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Low memory warning, arg1KB, arg2KB.
Arguments
  • arg1 = total memory size
  • arg2 = threshold value
Detailed Description
A low memory condition was detected. If this condition continues, a failover or a reset may occur.
Recommended Response Action
If multiple resets occur, If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Audit (MEM = Memory)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM8502

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
ECC Memory error rate failover condition detected.
Detailed Description
An ECC memory condition was detected on the primary CMC and a failover was initiated.
Recommended Response Action
Reseat the primary CMC and initiate a failover back to the primary CMC. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
Audit (MEM = Memory)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM8503

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Usage of high memory arg1 KB is detected for storage management module.
Arguments
  • arg1 = total memory size
Detailed Description
Usage of high memory is detected for storage management module.
Recommended Response Action
Reset the primary CMC and initiate failover back to the primary CMC.
Category
Audit (MEM = Memory)
Severity
Warning
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
No alerts are applicable for this message

MEM9000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory interconnect degraded.
Detailed Description
An issue is detected in the propagation of signals between the processor and the memory.
Recommended Response Action
Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Memory interconnect degraded. Reseat memory riser.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9001

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory interconnect is functioning normally.
Detailed Description
The memory interconnect is functioning normally.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
LCD Message
Memory interconnect normal.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Intel QPI interconnect arg1 has a correctable error.
Arguments
  • arg1 = number
Detailed Description
A correctable error was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Intel QPI interconnect <number> has a correctable error.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Intel SMI 2 Memory interconnect arg1 has a correctable error.
Arguments
  • arg1 = number
Detailed Description
A correctable error was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Intel SMI 2 Memory interconnect <number> has a correctable error.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Intel QPI interconnect arg1 has degraded.
Arguments
  • arg1 = number
Detailed Description
A link degradation was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message. The system will continue to operate at reduced performance.
Recommended Response Action
Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Intel QPI interconnect <number> has degraded. Reseat processor.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Intel SMI 2 Memory interconnect arg1 has degraded.
Arguments
  • arg1 = number
Detailed Description
A link degradation was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Intel SMI 2 interconnect <number> degraded. Reseat memory riser.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Intel QPI interconnect arg1 has a non-recoverable issue.
Arguments
  • arg1 = number
Detailed Description
A non-recoverable link issue was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Intel QPI interconnect <number> has fatal error. Reseat memory riser.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Intel SMI 2 Memory interconnect arg1 has a non-recoverable issue.
Arguments
  • arg1 = number
Detailed Description
A non-recoverable link issue was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
Recommended Response Action
Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Intel SMI 2 interconnect <number> has fatal error. Reseat mem riser.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Intel DDR Memory interconnect arg1 has a non-recoverable issue.
Arguments
  • arg1 = number
Detailed Description
A non-recoverable issue was detected in the propagation of signals on the Intel DDR memory interconnect identified in the message.
Recommended Response Action
Reseat all DIMMs on the memory riser, reseat the memory riser, and restart the server. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Intel DDR interconnect <number> has fatal error. Reseat mem riser.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Intel DDR Memory interconnect arg1 has a correctable error.
Arguments
  • arg1 = number
Detailed Description
A correctable error was detected in the propagation of signals on the Intel DDR memory interconnect identified in the message.
Recommended Response Action
Do the following: 1) Reseat all DIMMs on the memory riser, 2) Reseat the memory riser, and 3) Restart the server. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Intel DDR interconnect <number> has a correctable error. Reseat mem riser.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9010

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A QuickPath Interconnect (QPI) Reference Code warning message code is logged.
Detailed Description
BIOS logged the major and minor code of a QuickPath Interconnect (QPI) Reference Code warning. This information can be reviewed by using a tool which displays raw IPMI SEL log data such as IPMItool with the -vvv option or RACADM with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9011

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
QuickPath Interconnect (QPI) Reference Code warning location information is logged.
Detailed Description
BIOS logged location information of a QuickPath Interconnect (QPI) warning. This information can be reviewed by using a tool which displays raw IPMI SEL data such as IPMItool with the -vvv option or RACADM with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Warning
LCD Message
QuickPath Interconnect (QPI) reference code warning.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9012

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A Memory Reference Code (MRC) warning code is logged.
Detailed Description
BIOS logged the major and minor code of a Memory Reference Code (MRC) warning. This information can be reviewed by using a tool which displays raw IPMI SEL data such as IPMI tool with the -vvv option or RACADM with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9013

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Memory Reference Code (MRC) warning location information is logged.
Detailed Description
BIOS logged location information of a Memory Reference Code (MRC) warning. This information can be reviewed by using a tool which displays raw IPMI SEL data such as IPMItool with the -vvv option or RACADM with the -E option.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Warning
LCD Message
Memory Reference Code (MRC) warning.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9014

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A correctable memory error has occurred in Dual In-line Memory Module (DIMM) device arg1.
Arguments
  • arg1 = location
Detailed Description
The memory device identified in the message has encountered a correctable memory error. This may be an early indicator of a possible future uncorrectable error.
Recommended Response Action
This is a correctable error. Review log information and if multiple correctable errors have occurred on the DIMM identified in the message, re-install the memory device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
LCD Message
DIMM <location> has a correctable memory error.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9015

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Multi-bit memory errors detected on a Dual In-line Memory Module (DIMM) device arg1.
Arguments
  • arg1 = location
Detailed Description
The memory device identified in the message has encountered a uncorrectable error. System performance may be degraded. The operating system and/or applications may fail as a result.
Recommended Response Action
Re-install the memory component identified in the message. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9016

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Correctable memory error rate exceeded for Dual In-line Memory Module (DIMM) arg1.
Arguments
  • arg1 = location
Detailed Description
The memory device identified in the message may not be operational. This an early indicator of a possible future uncorrectable error.
Recommended Response Action
Re-install the memory component identified in the message. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
LCD Message
DIMM <location> exceeded correctable memory error rate.
Redfish Event Type
Not Applicable
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9020

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is about to reach the end of supported life duration.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot, identified in the message, is about to reach the end of supported life duration.
Recommended Response Action
During the next scheduled maintenance, replace the Non-Volatile Dual In-line Memory Module (NVDIMM) device. For more information about the usage of NVDIMMs, see the system Owners Manual on the support site.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
The NVDIMM in <location> is approaching the end of supported life.
OMSA Event ID
5426
OMSA Trap ID
5426
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9021

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) in slot arg1 is running the backup firmware image because the primary firmware has issues.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM in the slot identified in the message is running the backup firmware image because the primary firmware image has issues.
Recommended Response Action
Update the Non-Volatile Dual In-line Memory Module(NVDIMM) to the latest firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
The NVDIMM in <location> is running backup firmware.
OMSA Event ID
5426
OMSA Trap ID
5426
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9022

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A Non-Critical event was detected on the Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device identified in the message has encountered a Non-Critical event.
Recommended Response Action
If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
NVDIMM <location> has a Non-Critical event.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9030

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is not responding and is disabled.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message is not responding and is disabled.
Recommended Response Action
Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
The NVDIMM in <location> is not responding and has been disabled.
OMSA Event ID
5427
OMSA Trap ID
5427
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9031

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is unable to save the data during the previous system shutdown operation or power loss.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message is unable to save the data during the previous system shutdown operation or power loss. The NVDIMM is placed in write-protect mode.
Recommended Response Action
Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
The NVDIMM in <location> was not able to save its data and has been placed in write protect mode.
OMSA Event ID
5428
OMSA Trap ID
5428
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9032

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is unable to restore the data that was saved in the previous save operation.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message is unable to restore the data that was saved in the previous save operation. The NVDIMM is placed in write-protect mode.
Recommended Response Action
Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
The NVDIMM in <location> was not able to restore its data from its previous save operation and has been placed in write protect mode.
OMSA Event ID
5429
OMSA Trap ID
5429
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9033

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device is of unsupported configuration and unable to operate as currently configured.
Detailed Description
An NVDIMM device is of unsupported configuration and unable to operate as currently configured.
Recommended Response Action
Review the memory configuration and make sure the configuration is as per memory rules defined in the system Owners Manual on the support site.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Illegal NVDIMM configuration detected.
OMSA Event ID
5430
OMSA Trap ID
5430
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9034

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is not responding.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message is not responding.
Recommended Response Action
Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
The NVDIMM in <location>is not responding.
OMSA Event ID
5431
OMSA Trap ID
5431
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9035

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 cannot be configured to save data during a power loss because of an issue in the NVDIMM.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message cannot be configured to save data during a power loss because of an issue in the NVDIMM.
Recommended Response Action
Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Unable to arm the NVDIMM in <location>.
OMSA Event ID
5432
OMSA Trap ID
5432
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9036

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) devices are placed in write-protect mode because the system may not provide sufficient power to save data in case of power loss.
Detailed Description
The NVDIMM devices are placed in write-protect mode because the server may not provide sufficient power or the battery is not sufficiently charged to save data in case of power loss.
Recommended Response Action
Review any preceding power or battery entries in the log and resolve the issues. Refer to your documentation for details on how to view the log.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
All NVDIMMs are placed in Wrte Protect mode.
OMSA Event ID
5433
OMSA Trap ID
5433
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9037

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 has reached the end of supported life duration and is placed in write-protect mode.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message has reached the end of supported life duration and is placed in write-protect mode.
Recommended Response Action
Replace the Non-Volatile Dual In-line Memory Module (NVDIMM) device. For information about removing and reinstalling the NVDIMM, see the system Owners Manual on the support site.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
The NVDIMM in <location> has reached the end of supported life.
OMSA Event ID
5434
OMSA Trap ID
5434
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9038

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 has lost persistency and is placed in write-protect mode.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message has lost persistency and is placed in write-protect mode.
Recommended Response Action
Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
The NVDIMM in <location> has lost persistency and is placed in write-protect mode.
OMSA Event ID
5435
OMSA Trap ID
5435
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9039

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 was unable to be initialized.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message was unable to clear its storage media as part of the initialization process and is disabled.
Recommended Response Action
Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
The NVDIMM in <location> was unable to be initialized and has been disabled.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9040

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
A Critical event was detected on the Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message has encountered a critical error. System performance may be degraded. The operating system and/or applications may fail as a result.
Recommended Response Action
Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Critical
Trap/EventID
2265
LCD Message
Critical event on NVDIMM in slot <location>.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9050

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 has regained persistency and is available for use.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message has regained persistency and is available for use.
Recommended Response Action
No response action required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
OMSA Event ID
5425
OMSA Trap ID
5425
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9060

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The self-heal operation successfully completed on the memory module.
Detailed Description
The self-heal operation successfully completed on the memory module.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9061

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
An Information-Only event was detected on the Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1. The NVDIMM is operating normally.
Arguments
  • arg1 = location
Detailed Description
The NVDIMM device in the slot identified in the message is functioning normally.
Recommended Response Action
No response action is required.
Category
System Health (MEM = Memory)
Severity
Informational
Trap/EventID
2267
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9070

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The erase operation on the non-volatile DIMM with serial number arg1 in slot arg2 is successfully completed.
Arguments
  • arg1 = serial number
  • arg2 = slot number
Detailed Description
The erase operation for the specified DIMM completed successfully.
Recommended Response Action
No response action is required but it is recommended that the system be upgraded to the latest BIOS.
Category
Configuration (MEM = Memory)
Severity
Informational
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9071

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to complete the erase operation on the non-volatile DIMM with serial number arg1 in slot arg2.
Arguments
  • arg1 = serial number
  • arg2 = slot number
Detailed Description
The erase operation could not be completed for the DIMM identified in the message.
Recommended Response Action
Retry the operation. If the issue persists, contact your service provider. It is also recommended that the system be upgraded to the latest BIOS.
Category
Configuration (MEM = Memory)
Severity
Critical
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

MEM9072

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
The system memory has detected an error on a memory transaction at the location arg1. Reboot the system for auto-healing.
Arguments
  • arg1 = location
Detailed Description
The system has detected a memory error which cannot be immediately corrected.The OS has been notified of the memory error location.Recommended action is to warm reboot the system to initiate auto-healing and to reinitialize memory for optimized performance.
Recommended Response Action
Perform a warm reboot to allow server to attempt self-healing or self-correction. If a warm reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Trap/EventID
2266
LCD Message
Warning event at <location>. Warm reboot system.
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

MEM9073

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Unable to update firmware on a Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1.
Arguments
  • arg1 = location
Detailed Description
Unable to update firmware for the NVDIMM identified in the message.
Recommended Response Action
Retry the operation. If the issue not resolved, replace the NVDIMM, or If the issue persists,Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
Category
System Health (MEM = Memory)
Severity
Warning
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
Applicable Event or Alert Types
CMC—Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\