NVTP0001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to validate the topology because a different type of IOM is found in the slot pair.
- Detailed Description
- The topology validation failed because of a different type of IOM found in the slot pair in the chassis.
- Recommended Response Action
- Make sure that the IOMs of the same type occupy the same slot pair in a chassis.
- Category
- Configuration (NVTP = Topology)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
NVTP0002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to validate the MX7116n Fabric Expander Module because the slot number of the MX7116n Fabric Expander Module and the slot number of the Network IOM are different.
- Detailed Description
- The MX7116n Fabric Expander Module validation failed because the MX7116n Fabric Expander Module slot number and the Network IOM slot number are different.
- Recommended Response Action
- Make sure that the slot number of the MX7116n Fabric Expander Module and the slot number of the Network IOM are the same like (A or B) [1]----(A or B) [1] and (A or B) [2]----(A or B) [2]. Mezz cards can be different either A or B but slot number should be same.
- Category
- Configuration (NVTP = Topology)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message