- Message
- Internal Dual SD Module is redundant.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Informational
- Trap/EventID
- 2491
- OMSA Event ID
- 5304
- OMSA Trap ID
- 5304
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
RRDU0002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Internal Dual SD Module redundancy is lost.
- Detailed Description
- Either one of the SD card or both the SD cards are not functioning properly.
- Recommended Response Action
- Replace the failed SD card.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Critical
- Trap/EventID
- 2489
- LCD Message
- Internal Dual SD Module redundancy lost. Check SD cards
- OMSA Event ID
- 5306
- OMSA Trap ID
- 5306
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
RRDU0003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Internal Dual SD Module redundancy is degraded.
- Detailed Description
- Either one of the SD card or both the SD cards are not functioning properly.
- Recommended Response Action
- Replace the failed SD card.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Warning
- Trap/EventID
- 2490
- LCD Message
- Internal Dual SD Module redundancy is degraded.
- OMSA Event ID
- 5305
- OMSA Trap ID
- 5305
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
- Applicable Event or Alert Types
- CMC—Not Applicable
RRDU0004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Internal Dual SD Module is not redundant.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Install additional SD card and configure for redundancy if redundancy is desired.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Informational
- Trap/EventID
- 2491
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
RRDU0005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Internal Dual SD Module is not redundant. Insufficient resources to maintain normal operations.
- Detailed Description
- The current operating configuration cannot maintain redundancy. The unit may operate in a degraded state.
- Recommended Response Action
- Review product documentation and SD card configuration.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Critical
- LCD Message
- Internal Dual SD Module is not redundant. Insufficient resources. Check SD Cards
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
RRDU0006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Internal Dual SD Module rebuild initiated.
- Detailed Description
- Internal Dual SD Module rebuild initiated.
- Recommended Response Action
- No response action is required.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Informational
- Trap/EventID
- 2491
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
RRDU0007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Internal Dual SD Module rebuild completed successfully.
- Detailed Description
- Internal Dual SD Module rebuild completed successfully.
- Recommended Response Action
- No response action is required.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Informational
- Trap/EventID
- 2491
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
RRDU0008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Internal Dual SD Module rebuild did not complete successfully.
- Detailed Description
- Internal Dual SD Module rebuild failed because read/write to one of the SD cards failed.
- Recommended Response Action
- Replace the failed SD card and retry rebuild.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Critical
- Trap/EventID
- 2489
- LCD Message
- Internal Dual SD Module rebuild failed. Replace failed SD card.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
RRDU0010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Internal SD Module redundancy is disabled.
- Detailed Description
- Redundancy is not currently enabled for the Internal SD Module.
- Recommended Response Action
- No response action is required.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Informational
- OMSA Event ID
- 5302
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
RRDU0011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to determine the redundancy status of the Internal SD Module.
- Detailed Description
- This occurs because of one of the following reasons: 1) Either one of the SD card or both the SD cards have failed. 2) The Internal SD Module has failed.
- Recommended Response Action
- Replace the failed SD card with a new SD card, or replace the Internal SD Module. For more information, contact your service provider.
- Category
- System Health (RRDU = IDSDM Redundancy)
- Severity
- Warning
- OMSA Event ID
- 5301
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message