PowerEdge Servers Error and Event Messages Reference Guide
SSD—SSD Devices Event Messages
SSD0001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Write Endurance of Solid state drive (SSD) arg1 is less than the threshold value of Remaining Write Rated Endurance.
- Arguments
- arg1 = drive FQDD
- Detailed Description
- The Write Endurance of solid state drive identified in the message is less than the threshold value of Remaining Write Rated Endurance.
- Recommended Response Action
- No action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Warning
- Trap/EventID
- 4370
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
SSD0002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Available Spare of solid state drive (SSD) arg1 is arg2 which is less than the threshold value arg3.
- Arguments
- arg1 = drive FQDD
- arg2 = available spare
- arg3 = Threshold spare
- Detailed Description
- The Available Spare of solid state drive identified in the message is less than the threshold value of Available Spare Alert.
- Recommended Response Action
- No action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Warning
- Trap/EventID
- 4370
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
SSD1001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Write-cache on arg1 is enabled.
- Arguments
- arg1 = PCIe SSD name
- Detailed Description
- Write-cache is enabled on the PCIe solid state drive (SSD) identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Warning
- OMSA Event ID
- 2427
- OMSA Trap ID
- 90300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Write-cache on arg1 is disabled.
- Arguments
- arg1 = PCIe SSD name
- Detailed Description
- Write-cache is disabled on the PCIe solid state drive (SSD) identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Warning
- OMSA Event ID
- 2428
- OMSA Trap ID
- 90300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- arg1 is ready for removal.
- Arguments
- arg1 = PCIe SSD name
- Detailed Description
- The PCIe solid state drive (SSD) identified in the message is ready for removal.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2429
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Exported the arg1 log file.
- Arguments
- arg1 = PCIe SSD name
- Detailed Description
- The log file of the PCIe solid state drive (SSD) identified in the message is successfully exported.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2430
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Successfully initialized arg1.
- Arguments
- arg1 = PCIe SSD name
- Detailed Description
- The initialization of the PCIe solid state drive (SSD) identified in the message is complete.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2431
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 has reached arg2 of warranted device wear-out limit.
- Arguments
- arg1 = PCIe solid state device name
- arg2 = percent
- Detailed Description
- The PCIe solid state device identified in the message is approaching the warranted wear-out limit.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2433
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 has reached or exceeded its warranted wear-out limit.
- Arguments
- arg1 = PCIe solid state device name
- Detailed Description
- The solid state device identified in the message has either reached or exceeded the warranted wear-out limit.
- Recommended Response Action
- No action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2434
- OMSA Trap ID
- 90300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 is approaching read-only mode.
- Arguments
- arg1 = PCIe solid state device name
- Detailed Description
- The PCIe solid state device identified in the message is between 90% and 100% of reaching read-only mode.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2435
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 is in read-only mode.
- Arguments
- arg1 = PCIe solid state device name
- Detailed Description
- The PCIe solid state device identified in the message is in read-only mode.
- Recommended Response Action
- Back up the data on the device, and contact your service provider for further instructions.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Critical
- OMSA Event ID
- 2436
- OMSA Trap ID
- 90400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The arg1 is in a security locked state.
- Arguments
- arg1 = PCIe solid state device name
- Detailed Description
- The PCIe solid state device identified in the message is in a locked state, because an existing initialization task was interrupted due to a power failure or disk removal.
- Recommended Response Action
- Run Full Initialize operation on the device identified in the message.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Warning
- OMSA Event ID
- 2432
- OMSA Trap ID
- 90200
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Remaining Rated Write Endurance Threshold for PCIe SSDs is set to arg1.
- Arguments
- arg1 = value
- Detailed Description
- The Remaining Rated Write Endurance (RRWE) Threshold for PCIe solid state devices has been modified. A warning alert is generated when the RRWE for any PCIeSSD device falls below the user set RRWE Threshold value.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2449
- OMSA Trap ID
- 10100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Remaining Rated Write Endurance Threshold for SAS and SATA SSDs is set to arg1.
- Arguments
- arg1 = value
- Detailed Description
- The Remaining Rated Write Endurance (RRWE) Threshold for SAS and SATA solid state devices has been modified. A warning alert when the RRWE for any SAS or SATA SSD falls below the threshold set by the user.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2448
- OMSA Trap ID
- 10100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Available Spare Warning threshold for PCIe solid state drives (SSDs) is set to arg1.
- Arguments
- arg1 = value
- Detailed Description
- The Available Spare Warning threshold for PCIe solid state drives (SSDs) is set to the value identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2452
- OMSA Trap ID
- 10100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Available Spare value of PCI solid state drive arg1 is less than the Warning threshold value.
- Arguments
- arg1 = PCIe SSD name
- Detailed Description
- The Available Spare value of PCI solid state drive (SSDs) is less than the Warning threshold value.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Warning
- OMSA Event ID
- 2453
- OMSA Trap ID
- 10300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The available spare critical threshold value of PCIe Solid State Drives (SSDs) is set to arg1.
- Arguments
- arg1 = value
- Detailed Description
- The available spare critical threshold value of PCIe Solid State Drives (SSDs) is set to the value identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2459
- OMSA Trap ID
- 10100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The available spare critical threshold value of PCIe Solid State Drives (SSDs) is less than the critical threshold value.
- Detailed Description
- The available spare critical threshold value of PCIe Solid State Drives (SSDs) is less than the critical threshold value.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Critical
- OMSA Event ID
- 2457
- OMSA Trap ID
- 10400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1017
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The available spare critical threshold value of PCIe Solid State Drives (SSDs) has reached zero.
- Detailed Description
- The available spare critical threshold value of PCIe Solid State Drives (SSDs) has reached zero.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Critical
- OMSA Event ID
- 2458
- OMSA Trap ID
- 10400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1018
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The telemetry log file is successfully exported for the arg1.
- Arguments
- arg1 = physical device FQDD
- Detailed Description
- The telemetry log file is successfully exported for the physical device identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Informational
- OMSA Event ID
- 2491
- OMSA Trap ID
- 90100
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
SSD1019
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the Export Telemetry Log operation for the arg1 because of internal issues.
- Arguments
- arg1 = physical device FQDD
- Detailed Description
- The Export Telemetry Log operation for the physical device identified in the message cannot be completed because of internal issues.
- Recommended Response Action
- Retry the operation after some time.
- Category
- Storage (SSD = SSD Devices)
- Severity
- Warning
- OMSA Event ID
- 2492
- OMSA Trap ID
- 90300
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message