Lifecycle Controller User's Guide
Firmware update
With Lifecycle Controller, the system can be updated using the repositories accessible through FTP, a network share or on a locally attached USB drive or a DVD. Use the Firmware Update page to:
- View the current version of the installed applications and firmware.
- View a list of available updates.
- Select the required updates, downloads (automatic), and then apply the updates to the following components listed in the table:
The following table lists the components that support the Firmware Updatefeature:
| Component Name | Firmware Rollback Supported? (Yes or No) | Out-of-band—System Restart Required? |
|---|---|---|
| Diagnostics | No | No |
| Operating system Driver Pack | No | No |
| BIOS | Yes | Yes |
| RAID Controller | Yes | Yes |
| SAS HBA | Yes (HBA345 and higher) | Yes |
| Backplanes** | Yes | Yes |
| Enclosures | Yes | Yes |
| NIC | Yes | Yes |
| iDRAC | Yes | Yes |
| Power Supply Unit | Yes | Yes |
| CPLD | No | Yes |
|
NOTE:After the CPLD firmware upgrade is complete, iDRAC restarts automatically.
|
||
| FC Cards | Yes | Yes |
| HHHL NVMe adapter | Yes | Yes |
| NVMe PCIe SSD drives | Yes | Yes |
| Intel® Optane™ DC Persistent Memory | Yes | No |
| CMC* | No | Yes |
| Operating System Collector | No | No |
| BOSS | Yes | Yes |
| NVDIMM | Yes | Yes |
| Systems Management Application | No | Yes |
| Storage Enclosure Processor | Yes | Yes |
| IDSDM | No | Yes |
| Firmware Inventory/Firmware Version | No | No |
|
NOTE:Since release 5.10.00.00, there is no support for FW version display even for SAS/SATA HDD in LCUI.
NOTE:Error message may not be proper while updating Pensendo firmware from LCUI.
|
||
* Indicates that though a system restart is not required, iDRAC must be restarted to apply the updates. iDRAC communication and monitoring will temporarily be interrupted.
** The backplanes that cannot be updated are not listed.
***Applicable only for FX2 modular systems.
An expander backplane FW update requires the primary SAS RAID/HBA controller to be enabled. If the controller is disabled via the enable/disable internal RAID controller or the PCI-e slot is disabled at the BIOS level, the backplane FW update job is expected to fail.
The SAS controller must be re-enabled to allow the expander backplane firmware to update successfully. After the update has been applied, the controller can be returned to its previous disabled state.
- TPM
- GPU
- SAS and SATA
- Software Defined Persistent Memory (SDPM)
- Vault Optimized Storage Solution (VOSS)
- DPU
- FPGA
- Power Distribution Board (PDB) CPLD
- iDRAC SDK plugin