Dell OpenManage Enterprise-Modular Edition Version 2.20.10 for PowerEdge MX7000 Chassis RACADM Command Line Reference Guide

PDF

faultlist

Description
Displays the active error message in the chassis subsystem.
Synopsis
racadm faultlist view
$ racadm faultlist view
Example
SubSystem  = System.Modular.7
Message    = CPU 1 is absent
InstanceId  = Fault#02200004#1
Severity   = Critical
MessageId   = CPU0003
SubSystem  = PowerSupply
Message    = The power input of power supply 1 is lost.
InstanceId  = Fault#02200005#1
Severity   = Critical
MessageId   = PSU0003
SubSystem  = PowerSupply
Message    = The power input of power supply 5 is lost.
InstanceId  = Fault#02200006#1
Severity   = Critical
MessageId   = PSU0005