Dell OpenManage Enterprise-Modular Edition Version 2.20.10 for PowerEdge MX7000 Chassis RACADM Command Line Reference Guide
getsensorinfo
- Description
- Displays system sensors.
- Synopsis
-
racadm getsensorinfo
racadm getsensorinfo -c
Where, -c—Compact output format - Example
-
racadm getsensorinfo
- Chassis with AC power supply type
<senType> <Num> <sensorName> <status> <reading> <units> <LC> <UC> <PWM> FanSpeed 1 Fan-1 Not OK N/A rpm N/A N/A 0 FanSpeed 2 Fan-2 OK 17166 rpm N/A N/A 100 FanSpeed 3 Fan-3 OK 17250 rpm N/A N/A 100 FanSpeed 4 Fan-4 OK 17096 rpm N/A N/A 100 FanSpeed 5 Fan-5 OK 14513 rpm N/A N/A 100 FanSpeed 6 Fan-6 Not OK N/A rpm N/A N/A 0 FanSpeed 7 Fan-7 OK 14510 rpm N/A N/A 100 FanSpeed 8 Fan-8 OK 14479 rpm N/A N/A 100 FanSpeed 9 Fan-9 OK 14484 rpm N/A N/A 100 <senType> <Num> <sensorName> <status> <reading> <units> <LC> <UC> Temp 1 Chassis Inlet Temperature OK 27 Celsius -7 47 <senType> <Num> <sensorName> <status> <health> <Power Supply type> PWR 1 PS-1 Online OK AC PWR 2 PS-2 Input Lost Not OK AC PWR 3 PS-3 Slot Empty N/A AC PWR 4 PS-4 Online OK AC PWR 5 PS-5 Configuration Error Not OK AC PWR 6 PS-6 Slot Empty N/A AC
-
Chassis with DC power supply type
<senType> <Num> <sensorName> <status> <reading> <units> <LC> <UC> <PWM> FanSpeed 1 Fan-1 OK 5301 rpm N/A N/A 28 FanSpeed 2 Fan-2 OK 5356 rpm N/A N/A 28 FanSpeed 3 Fan-3 OK 4556 rpm N/A N/A 24 FanSpeed 4 Fan-4 OK 4866 rpm N/A N/A 26 FanSpeed 5 Fan-5 OK 10334 rpm N/A N/A 74 FanSpeed 6 Fan-6 OK 10349 rpm N/A N/A 74 FanSpeed 7 Fan-7 OK 10316 rpm N/A N/A 74 FanSpeed 8 Fan-8 OK 6335 rpm N/A N/A 44 FanSpeed 9 Fan-9 OK 6330 rpm N/A N/A 44 <senType> <Num> <sensorName> <status> <reading> <units> <LC> <UC> <LW> <UW> Temp 1 Chassis Inlet Temperature OK 30 Celsius -7 47 3 43 Temp 2 Sled 7 Inlet Temperature OK 28 Celsius -7 47 3 43 Temp 3 Sled 2 Inlet Temperature OK 27 Celsius -7 47 3 43 Temp 4 Sled 3 Inlet Temperature OK 27 Celsius -7 42 3 38 Temp 5 Sled 4 Inlet Temperature OK 28 Celsius -7 47 3 43 Temp 6 Sled 5 Inlet Temperature OK 28 Celsius -7 47 3 43 Temp 7 Sled 6 Inlet Temperature OK 28 Celsius -7 42 3 38 <senType> <Num> <sensorName> <status> <health> <Power Supply type> PWR 1 PS-1 Online OK DC PWR 2 PS-2 Online OK DC PWR 3 PS-3 Online OK DC PWR 4 PS-4 Online OK DC PWR 5 PS-5 Online OK DC PWR 6 PS-6 Online OK DC
- Chassis with AC power supply type
- Example
-
racadm getsensorinfo -c
Sensor Type: Fan <Num> <sensorName> <status> <reading> <LC> <UC> 1 Fan-1 Not OK N/A rpm N/A N/A 2 Fan-2 OK 17174 rpm N/A N/A 3 Fan-3 OK 17238 rpm N/A N/A 4 Fan-4 OK 17081 rpm N/A N/A 5 Fan-5 OK 14499 rpm N/A N/A 6 Fan-6 Not OK N/A rpm N/A N/A 7 Fan-7 OK 14502 rpm N/A N/A 8 Fan-8 OK 14505 rpm N/A N/A 9 Fan-9 OK 14479 rpm N/A N/A Sensor Type: Temp <Num> <sensorName> <status> <reading> <LC> <UC> <LW> <UW> 1 Chassis Inlet Temperature OK 29 C -7 47 3 43 2 Sled 2 Inlet Temperature OK 24 C -7 47 3 43 3 Sled 3 Inlet Temperature OK 25 C -7 42 3 38 4 Sled 4 Inlet Temperature OK 25 C -7 47 3 43 5 Sled 5 Inlet Temperature OK 26 C -7 47 3 43 6 Sled 6 Inlet Temperature OK 26 C -7 42 3 38 7 Sled 7 Inlet Temperature OK 26 C -7 47 3 43 Sensor Type: Power <Num> <sensorName> <status> <health> <Power Supply type> 1 PS-1 Slot Empty N/A AC 2 PS-2 Online OK AC 3 PS-3 Slot Empty N/A AC 4 PS-4 Online OK AC 5 PS-5 Configuration Error Not OK AC 6 PS-6 Input Lost Not OK AC