Dell OpenManage Enterprise-Modular Edition Version 2.20.10 for PowerEdge MX7000 Chassis RACADM Command Line Reference Guide

PDF

serveraction

Description
Manages the server or storage power. The supported actions are:
  • powerdown—performs server power off.
  • powerup—performs server power-on.
  • powercycle—performs server power cycle.
  • hardreset—force hard server power reset.
  • graceshutdown—perform graceful shutdown of server.
  • reseat—perform a virtual reseat of a server or storage.
    NOTE:This action requires -f option to force the action.
    NOTE:reseat is the only action which can be performed for the storage devices.
  • powerstatus—display current power status of server.
    NOTE:This action is not allowed with -a option.
    NOTE:The serveraction reseat operation is supported only with chassis administrator user role privileges.
Synopsis
racadm serveraction -m <module> <action>
racadm serveraction -a <action>
Input
  • -m—The <module> must be server-<n>, where n = 1 to 8
  • -a—Performs power action on all servers
Example
  • Power action on a single server:
    racadm serveraction -m server-1 powerdown
  • Power action on all servers:
    racadm serveraction -a powerup
  • Reseat action on a single storage:
    racadm serveraction -m storage-2 -f reseat