Dell PowerEdge R360 Installation and Service Manual
Cable routing
6 x 2.5-inch hot-swappable SAS/SATA drives through PERC + 2 x 2.5-inch direct attach NVMe
NOTE:Cable routing image and table is work in progress.

NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order.
| Order | From | To |
|---|---|---|
| 1 | SL1_PCH_SA1 (system board signal connector) | BP_DST_SA1 (backplane signal connector) |
| 2 | PIB (system board connector) | PIB_SIG_1 (PIB signal connector) |
| 3 | P1 (system board power connector) | SYS (PIB power connector) |
| 4 | P2 (system board power connector) | CPU (PIB power connector) |
| 5 | SIG_PWR_1(PIB power connector) | BP_PWR_1 (backplane power connector) |
| 6 | CTRL_PNL (system board control panel connector) | Right Ear |
| 7 | LEFT_LED (system board control panel connector) | Left Ear |
| 8 | R_INTRUSION (system board intrusion switch connector) | Intrusion switch |
| 9 | SL2_PCH_PA2 (system board signal connector) | J_PCIE_1 (BOSS N1 signal connector) |
| 10 | MB_BOSS_PWR (System board power connector) | J_PWR_1 (BOSS N1 power connector) |

NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order.
| Order | From | To |
|---|---|---|
| 1 | J_SLOT1 (fPERC Riser) | CTRL_DST_PA1 (fPERC connector) |
| 2 | PIB (system board connector) | PIB_SIG_1 (PIB signal connector) |
| 3 | P1 (system board power connector) | SYS (PIB power connector) |
| 4 | P2 (system board power connector) | CPU (PIB power connector) |
| 5 | SIG_PWR_1(PIB power connector) | BP_PWR_1 (backplane power connector) |
| 6 | SL2_PCH_PA2 (system board signal connector) | J_PCIE_1 (BOSS N1 signal connector) |
| 7 | MB_BOSS_PWR (System board power connector) | J_PWR_1 (BOSS N1 power connector) |

NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order.
| Order | From | To |
|---|---|---|
| 1 | CTRL_SRC_SA1 (adapter PERC controller connector) | BP_DST_SA1 (backplane signal connector) |
| 2 | PIB (system board connector) | PIB_SIG_1 (PIB signal connector) |
| 3 | P1 (system board power connector) | SYS (PIB power connector) |
| 4 | P2 (system board power connector) | CPU (PIB power connector) |
| 5 | SIG_PWR_1(PIB power connector) | BP_PWR_1 (backplane power connector) |

NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order.
| Order | From | To |
|---|---|---|
| 1 | J_SLOT1 (fPERC Riser) | CTRL_DST_PA1 (fPERC connector) |
| 2 | PIB (system board connector) | PIB_SIG_1 (PIB signal connector) |
| 3 | P1 (system board power connector) | SYS (PIB power connector) |
| 4 | P2 (system board power connector) | CPU (PIB power connector) |
| 5 | SIG_PWR_1(PIB power connector) | BP_PWR_1 (backplane power connector) |
| 6 | SL2_PCH_PA2 (system board signal connector) | J_PCIE_1 (BOSS N1 signal connector) |
| 7 | MB_BOSS_PWR (System board power connector) | J_PWR_1 (BOSS N1 power connector) |

NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order.
| Order | From | To |
|---|---|---|
| 1 | CTRL_SRC_SA1 (adapter PERC controller connector) | BP_DST_SA1 (backplane signal connector) |
| 2 | PIB (system board connector) | PIB_SIG_1 (PIB signal connector) |
| 3 | P1 (system board power connector) | SYS (PIB power connector) |
| 4 | P2 (system board power connector) | CPU (PIB power connector) |
| 5 | SIG_PWR_1(PIB power connector) | BP_PWR_1 (backplane power connector) |
NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse sequential order.