Dell PowerEdge R360 Installation and Service Manual

PDF

PSU specifications

The PowerEdgeR360system supports up to two AC or DC power supply units (PSUs).

Table 1. PSU specifications This table describes PSU specifications for the system.
PSU Class Heat dissipation (maximum) (BTU/hr) Frequency (Hz) Voltage AC DC Current (A)
High line 200–240 V Low line 100–120 V
600 W Platinum 2250 50/60 100 — 240 V AC 600 W 600 W NA 7.1 - 3.6
NA NA 240 V DC NA NA 600 W 2.9
700 W Titanium 2625 50/60 200 — 240 V AC 700 W NA NA 4.1
NA NA 240 V DC NA NA 700 W 3.4
NOTE:This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240 V.
NOTE:Heat dissipation is calculated using the PSU wattage rating.
NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system power consumption with the Enterprise Infrastructure Planning Tool atDell.com/calc.
Figure 1. PSU power cord
This image shows the C13 power connector
Table 2. PSU power cordsThe table lists the PSU power cords list
Form factor Output Power cord
Redundant 60 mm 600 W C13 /C14 (inlet)
700 W