Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell EMC PowerEdge R440 Installation and Service Manual

Replacing the optional internal USB memory key

Prerequisites

CAUTION To avoid interference with other components in the server, the maximum permissible dimensions of the USB memory key are 15.9 mm wide x 57.15 mm long x 7.9 mm high.
  1. Follow the safety guidelines listed in Safety instructions.
  2. Follow the procedure listed in Before working inside your system.

Steps

  1. Locate the USB port or USB memory key on the system board.
    To locate the USB port, see the Jumpers and connectors.
  2. If installed, remove the USB memory key from the USB port.
  3. Insert the replacement USB memory key into the USB port.

Next steps

  1. Follow the procedure listed in After working inside your system.
  2. While booting, press F2 to enter System Setup and verify that the system detects the USB memory key.

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\