Dell PowerEdge R530xd Owner's Manual

PDF

Installing the internal dual SD module

Prerequisites

  1. Ensure that you read the Safety instructions.
  2. Follow the procedure listed in Before working inside your system .
  3. If connected, disconnect the cables from expansion card (s).
  4. If installed, remove the expansion card riser (s).
    • NOTE: If required, close the expansion card latch on the cooling shroud to release the full length card.
  5. Remove the cooling shroud.
  • CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.

Steps

  1. Locate the IDSDM connector on the system board.
  2. Align the connectors on the system board and the dual SD module.
  3. Push the dual SD module until it is firmly seated on the system board.
  1. Install the SD media card(s).
  2. If removed, reinstall the PCIe expansion card riser (s).
  3. If disconnected, reconnect the cables to the expansion card(s).
  4. Reinstall the cooling shroud.
  5. If required open the expansion card latch on the cooling shroud to support the full length expansion card.
  6. Follow the procedure listed in After working inside your system .