Dell PowerEdge R530xd Owner's Manual

PDF

Removing the internal PERC riser

Prerequisites

  1. Ensure that you read the Safety instructions.
  2. Follow the procedure listed in Before working inside your system .
  3. If connected, disconnect the cables from the expansion card (s).
  4. If required, remove the dual riser module.
  5. Remove the cooling shroud

Steps

Hold the internal PERC riser module by the edges and lift it out of the server.
Figure 1. Removing and installing the internal PERC riser the figure shows removing and installing the internal PERC riser
  1. internal PERC riser
  2. guide slot on the internal PERC riser
  3. internal PERC riser
  4. guide pin on the chassis
  5. PCIe connector on system board
  1. Install the cooling shroud.
  2. If removed, reinstall the dual riser module.
  3. Reconnect all disconnected cables.
  4. If required, open the expansion card latch on the cooling shroud to support the full length expansion card.
  5. Follow the procedure listed in After working inside your system .