Dell EMC PowerEdge R550 Installation and Service Manual
Installing the processor heat sink module
Prerequisites
- Follow the safety guidelines listed in the Safety instructions.
- Follow the procedure listed in the Before working inside your system.
- Remove the air shroud.
- If installed, remove the processor dust cover.
Steps
- Set the anti-tilt wires to the unlocked position on the heat sink (inward position).
- Align the pin 1 indicator of the processor heat sink module (PHM) to the system board, and then place the PHM on the processor socket.
CAUTION:To avoid damaging the fins on the heat sink, do not press down on the heat sink fins.NOTE:Ensure that the PHM is held parallel to the system board to prevent damaging the components.
Figure 1. Installing the processor heat sink module 
- Set the anti-tilt wires to the locked position (outward position), and then using the Torx #T30 tool, tighten the captive nuts (8 in-lbf) on the PHM in the order below:
- In a random order, tighten the first nut three turns.
- Tighten the nut diagonally opposite to the nut you tighten first.
- Repeat the procedure for the remaining two nuts.
- Return to the first nut to tighten it completely.
- Check all the nuts to ensure they are firmly secured.
Figure 2. Setting the anti-tilt wires to the locked position and tighten the nuts 
Next steps
- Install the air shroud.
- Follow the procedure listed in the After working inside your system.