Dell EMC Boot Optimized Server Storage-S1 User's Guide
Firmware update using Windows
Following are the steps to update the firmware using the BOSS-S1 command line interface.
- Download the SAS-RAID_Firmware_xxxxx_UEFI_Axx.zip from www.dell.com/support/home and extract the zip file.
- Open the vs2015/windows folder. Example: C:\Desktop\mvsetup.xxxxx_Axx\windows\x64\cli
- Copy the firmware image binary from the SAS-RAID_Firmware_xxxxx_UEFI_Axx.zip folder to the directory where CLI file is located. Overwrite any existing files.NOTE: BOSS-S1 supports multiple sub device ID. Locate the correct sub device ID which is available in the iDRAC, BOSS-S1 HII, and BOSS-S1 OS CLI (Info -o hba).
Table 1. Supported SubDevice IDTable shows the supported SubDevice ID SubDevice ID Firmware Binary Link 1FD6 (Monolithic) ImageA1_1FD6.bin 1FE2 (Monolithic) ImageA1_1FE2.bin 1FDF (Modular) ImageA1.bin - Run mvsetup.exe.
- To flash the firmware, run the command flash –a update –f ImageA1_xxxx.bin –t raw in the CLI shell.
- Exit and reboot the system, and verify the firmware version.NOTE: Administrator privileges for Windows and Root/Sudo for Linux are recommended.