Following are the steps to update the firmware using the BOSS-S1 command line interface.
Download the SAS-RAID_Firmware_xxxxx_UEFI_Axx.zip from www.dell.com/support/home and extract the zip file.
Open the vs2015/windows folder. Example: C:\Desktop\mvsetup.xxxxx_Axx\windows\x64\cli
Copy the firmware image binary from the SAS-RAID_Firmware_xxxxx_UEFI_Axx.zip folder to the directory where CLI file is located. Overwrite any existing files.
NOTE: BOSS-S1 supports multiple sub device ID. Locate the correct sub device ID which is available in the iDRAC, BOSS-S1 HII, and BOSS-S1 OS CLI (Info -o hba).
Table 1. Supported SubDevice IDTable shows the supported SubDevice ID
SubDevice ID
Firmware Binary Link
1FD6 (Monolithic)
ImageA1_1FD6.bin
1FE2 (Monolithic)
ImageA1_1FE2.bin
1FDF (Modular)
ImageA1.bin
Run mvsetup.exe.
To flash the firmware, run the command flash –a update –f ImageA1_xxxx.bin –t raw in the CLI shell.
Exit and reboot the system, and verify the firmware version.
NOTE: Administrator privileges for Windows and Root/Sudo for Linux are recommended.
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\