Dell PowerEdge R7525 Installation and Service Manual
Expansion card installation guidelines
The following table describes the supported expansion cards:
| Expansion card riser | PCIe slots | Processor connection | Height | Length | Slot width |
|---|---|---|---|---|---|
| Riser 1 | Slot 1 | Processor 1 | Full Height (FH) | Half Length (HL) | x8 |
| x16 | |||||
| Slot 2 | x8 | ||||
| x16 | |||||
| Riser 2 | Slot 3 | Processor 1 | Low Profile (LP) | Half Length (HL) | x16 |
| Slot 6 | Processor 2 | ||||
| Riser 3 | Slot 4 | Processor 2 | Full Height (FH) | Half Length (HL) | x8 |
| Slot 5 | x16 | ||||
| Riser 4 | Slot 7 | Processor 2 | Full Height (FH) | Half Length (HL) | x8 |
| x16 | |||||
| x8 | |||||
| Slot 8 | x16 |
| Config # | RSR Configuration | # of CPUs | PERC type supported | Rear Storage Possible | x8 CPU 1 | x16 CPU 1 | x8 CPU 2 | x16 CPU 2 |
|---|---|---|---|---|---|---|---|---|
| 0 | NO RSR | 2 | None | No | 0 | 0 | 0 | 0 |
| 1 | R1B | 1 | Front PERC | No | 2 | 0 | 0 | 0 |
| 2 | R1B+R4B | 2 | Front PERC/PERC Adapter | No | 2 | 0 | 2 | 0 |
| 3-1 | R1A+R2A+R3A+R4A (FL) | 2 | Front PERC/PERC Adapter | No | 0 | 2 | 0 | 3 |
| 3-2 | R1A+R2A+R3A+R4A (HL) | 2 | Front PERC/PERC Adapter | No | 0 | 2 | 0 | 3 |
| 4 | R1B+R2A+R3B+R4B | 2 | Front PERC/PERC Adapter | No | 2 | 1 | 4 | 1 |
| 6 | R1C+R2A+R3A+R4C | 2 | PERC Adapter | No | 0 | 3 | 0 | 4 |
| 7 | R1D+R2A+R3B+R4D | 2 | None | No | 0 | 1 | 2 | 1 |
| 8-1 | R1A+R2A+R4A (FL) | 2 | PERC Adapter | Yes | 0 | 2 | 0 | 2 |
| 8-2 | R1A+R2A+R4A (HL) | 2 | PERC Adapter | Yes | 0 | 2 | 0 | 2 |
| 9 | R1B+R2A+R4B | 2 | PERC Adapter | Yes | 2 | 1 | 2 | 1 |
| 10 | R2A+R4B | 2 | PERC Adapter | Yes | 0 | 1 | 2 | 1 |
| 11 | R1D+R2A+R3B+R4B | 2 | None | No | 0 | 1 | 4 | 1 |
| 12-1 | R1D+R2A+R3A+R4A (FL) | 2 | None | No | 0 | 1 | 0 | 3 |
| 12-2 | R1D+R2A+R3A+R4A (HL) | 2 | None | No | 0 | 1 | 0 | 3 |
| 13-1 | R1A+R2A+R3A (FL) | 2 | Front PERC/PERC Adapter | No | 0 | 2 | 0 | 2 |
| 13-2 | R1A+R2A+R3A (HL) | 2 | Front PERC/PERC Adapter | No | 0 | 2 | 0 | 2 |
| 14 | R1B+R2A+R3B | 2 | Front PERC/PERC Adapter | No | 2 | 1 | 2 | 1 |
| 15 | R1D+R4D | 1 | None | No | 0 | 0 | 0 | 0 |
NOTE:The expansion-card slots are not hot-swappable.
The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be installed in the card priority and slot priority order.
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Inventec (BOSS-S2) ADPT,15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front PERC) H755 MXC | Internal slot | 1 |
| Inventec (Front PERC) H745 V3 | Internal slot | 1 |
| Inventec (Front PERC) H745 V2 | Internal slot | 1 |
| Inventec (Front PERC) H745 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 V2 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 | Internal slot | 1 |
| FOXCONN (Front PERC) H355 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i V2 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 V2 | Internal slot | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 1, 2 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 1, 2 | 2 |
| Intel (NIC: 25 Gb) DP,SFP | 1, 2 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 1, 2 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,FH | 1, 2 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,FH2 | 1, 2 | 2 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 1, 2 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 1, 2 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 1, 2 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 1, 2 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 1, 2 | 2 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 1, 2 | 2 |
| Emulex (HBA: FC32) FH,2P,LPE35002 | 1, 2 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 1, 2 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 1, 2 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 1, 2 | 2 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 1, 2 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 1, 2 | 2 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 1, 2 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 1, 2 | 2 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 1, 2 | 2 |
| Emulex (HBA: FC16) 2P,LPE31002 | 1, 2 | 2 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 1, 2 | 2 |
| QLogic (HBA: FC16) FH,SP,2690,V2 | 1, 2 | 2 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 1, 2 | 2 |
| QLogic (HBA: FC16) FH,DP,2692,V2 | 1, 2 | 2 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 1, 2 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,V2 | 1, 2 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 1, 2 | 2 |
| QLogic (NIC: 10 Gb) QP | 1, 2 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 1, 2 | 2 |
| Intel (NIC: 10 Gb) SFP+,V2 | 1, 2 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP | 1, 2 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP | 1, 2 | 2 |
| Broadcom (NIC: 10 Gb) DP,57416,FH | 1, 2 | 2 |
| Broadcom (NIC: 10 Gb) DP,57412,FH | 1, 2 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 1, 2 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 1, 2 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 1, 2 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 1, 2 | 2 |
| Intel (NIC: 1 Gb) QP,V3 | 1, 2 | 2 |
| Intel (NIC: 1 Gb) QP,F1 | 1, 2 | 2 |
| Broadcom (NIC: 1 Gb) QP,V2 | 1, 2 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2 | 1, 2 | 2 |
| FOXCONN (External Adapter) H840 FH,V3 | 1, 2 | 2 |
| FOXCONN (External Adapter) H840 | 1, 2 | 2 |
| FOXCONN (External Adapter) HBA355e | 1, 2 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA FH | 1, 2 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH | 1, 2 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA | 1, 2 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 1, 2 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 1, 2 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 1, 2 | 2 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 1, 2 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 1, 2 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 1, 2 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 1, 2 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 1, 2 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 1, 2 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 1, 2 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 1, 2 | 2 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 1, 2 | 2 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 1, 2 | 2 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 1, 2 | 2 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) ASSY,CRD,SER,FH,SVR,15G | 8 | 1 |
| FOXCONN (Front PERC) H755N | Internal slot | 1 |
| FOXCONN (Front PERC) H755N MXC | Internal slot | 1 |
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front PERC) H755 MXC | Internal slot | 1 |
| Inventec (Front PERC) H745 V3 | Internal slot | 1 |
| Inventec (Front PERC) H745 V2 | Internal slot | 1 |
| Inventec (Front PERC) H745 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 V2 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 | Internal slot | 1 |
| FOXCONN (Front PERC) H355 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i V2 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 2 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 2 | 1 |
| Inventec (PERC Adapter) H745 V2 | 2 | 1 |
| Inventec (PERC Adapter) H745 | 2 | 1 |
| FOXCONN (PERC Adapter) H355 | 2 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 2 | 1 |
| FOXCONN (PERC Adapter) H345 | 2 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 2 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 2 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 2 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 2 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 1, 2, 7, 8 | 4 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 1, 2, 7 | 3 |
| Intel (NIC: 25 Gb) DP,SFP | 1, 2, 7 | 3 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 1, 2, 7 | 3 |
| Broadcom (NIC: 25 Gb) DP,57414,FH | 1, 2, 7 | 3 |
| Broadcom (NIC: 25 Gb) DP,57414,FH2 | 1, 2, 7 | 3 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 1, 2, 7 | 3 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 1, 2, 7 | 3 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 1, 2, 7 | 3 |
| Emulex (HBA: FC64) FH,2P,S28 | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) 2P,LPE35002 | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) FH,2P,LPE35002 | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) FH,1P,S28 | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) FH,1P,S28 | 1, 2, 7 | 3 |
| QLogic (HBA: FC32) FH,1P,S28 | 1, 2, 7 | 3 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 1, 2, 7 | 3 |
| QLogic (HBA: FC32) FH,2P,S28 | 1, 2, 7 | 3 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 1, 2, 7 | 3 |
| Emulex (HBA: FC16) 1P,LPE31000 | 1, 2, 7 | 3 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 1, 2, 7 | 3 |
| Emulex (HBA: FC16) 2P,LPE31002 | 1, 2, 7 | 3 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 1, 2, 7 | 3 |
| QLogic (HBA: FC16) FH,SP,2690,V2 | 1, 2, 7 | 3 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 1, 2, 7 | 3 |
| QLogic (HBA: FC16) FH,DP,2692,V2 | 1, 2, 7 | 3 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 1, 2, 7 | 3 |
| QLogic (NIC: 10 Gb) DP,BT,V2 | 1, 2, 7 | 3 |
| QLogic (NIC: 10 Gb) SFP,QP | 1, 2, 7 | 3 |
| QLogic (NIC: 10 Gb) QP | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+ | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,V2 | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,DP | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,DP | 1, 2, 7 | 3 |
| Broadcom (NIC: 10 Gb) DP,57416,FH | 1, 2, 7 | 3 |
| Broadcom (NIC: 10 Gb) DP,57412,FH | 1, 2, 7 | 3 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) FH,4P,BT | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) FH,2P,BT | 1, 2, 7 | 3 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 1, 2, 7 | 3 |
| Intel (NIC: 1 Gb) QP,V3 | 1, 2, 7 | 3 |
| Intel (NIC: 1 Gb) QP,F1 | 1, 2, 7 | 3 |
| Broadcom (NIC: 1 Gb) QP,V2 | 1, 2, 7 | 3 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2 | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) H840 FH,V3 | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) H840 | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) HBA355e | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA FH | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA | 1, 2, 7 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 1, 2, 7, 8 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 1, 2, 7, 8 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 1, 2, 7, 8 | 4 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 1, 2, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 1, 2, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 1, 2, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 1, 2, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 1, 2, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 1, 2, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 1, 2, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 1, 2, 7, 8 | 4 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 1, 2, 7, 8 | 4 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 1, 2, 7, 8 | 4 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 1, 2, 7, 8 | 4 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| NVIDIA (GPU) T4,16 Gb,70W,L | 3, 6 | 2 |
| NVIDIA (GPU) A2,16 Gb,LP,V2 | 3, 6 | 2 |
| NVIDIA (GPU) M10,32 Gb,225 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) A100,40 Gb,250 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) A10,24 Gb,150 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) A10,24 Gb,V2 | 2, 5, 7 | 3 |
| NVIDIA (GPU) A30,24 Gb,165 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) A30,24 Gb,V2 | 2, 5, 7 | 3 |
| NVIDIA (GPU) A40,48 Gb,300 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) A40,48 Gb,V2 | 2, 5, 7 | 3 |
| NVIDIA (GPU) V100,16 Gb,250 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) V100S, 32 Gb,250 W,PCIe | 2, 5, 7 | 3 |
| AMD (GPU) MI100,32 Gb,300 W | 2, 5, 7 | 3 |
| AMD (GPU) MI210,64 Gb,300 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) RTX6000, 24 Gb | 2, 5, 7 | 3 |
| NVIDIA (GPU) RTX8000, 40 Gb | 2, 5, 7 | 3 |
| NVIDIA (GPU) RTX5000, 16 Gb | 2, 5, 7 | 3 |
| NVIDIA (GPU) A16,64 Gb,250 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) A16,64 Gb,V2 | 2, 5, 7 | 3 |
| NVIDIA (GPU) A100,80 Gb,300 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) A100,80 Gb,V2 | 2, 5, 7 | 3 |
| Xilinx (Accelerators - FPGAs) XLNX,225 W,PSV,FH | 2, 5, 7 | 3 |
| FOXCONN (Front PERC) H755N | Internal slot | 2 |
| FOXCONN (Front PERC) H755N MXC | Internal slot | 2 |
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front PERC) H755 MXC | Internal slot | 1 |
| Inventec (Front PERC) H745 V3 | Internal slot | 1 |
| Inventec (Front PERC) H745 V2 | Internal slot | 1 |
| Inventec (Front PERC) H745 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 V2 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 | Internal slot | 1 |
| FOXCONN (Front PERC) H355 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i V2 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3 | 1 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) DP,QSF | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) SFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,2P,LPE35002 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 3, 6 | 2 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31002 | 3, 6 | 2 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) 1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,LP,V2 | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,LP,F1 | 3, 6 | 2 |
| Broadcom (NIC: 1 Gb) LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100) PCIe,CX6,SP,L,ML | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | 3, 6 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 LP,V2 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA FH | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA | 3, 6 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6 | 2 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6 | 2 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6 | 2 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6 | 2 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) SVR,15G | 4, 8 | 1 |
| NVIDIA (GPU) T4,16 Gb,70W,V2 | 2, 5, 7 | 3 |
| NVIDIA (GPU) T4,16 Gb,70 W,L | 3, 6 | 2 |
| NVIDIA (GPU) A2,16 Gb,60 W | 2, 5, 7 | 3 |
| NVIDIA (GPU) A2,16 Gb,V2 | 2, 5, 7 | 3 |
| NVIDIA (GPU) A2,16 Gb,LP,V2 | 3, 6 | 2 |
| FOXCONN (Front PERC) H755N | Internal slot | 2 |
| FOXCONN (Front PERC) H755N MXC | Internal slot | 2 |
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front PERC) H755 MXC | Internal slot | 1 |
| Inventec (Front PERC) H745 V3 | Internal slot | 1 |
| Inventec (Front PERC) H745 V2 | Internal slot | 1 |
| Inventec (Front PERC) H745 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 V2 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 | Internal slot | 1 |
| FOXCONN (Front PERC) H355 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i V2 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 2, 5, 7 | 3 |
| Mellanox (NIC: 100G) LP,2P,Q56 | 3, 6 | 2 |
| NAPATECH (NIC: 100 Gb) DP,QSFP28 | 2, 5, 7 | 3 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSFP | 2, 5, 7 | 3 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) FH,2P,Q28 | 2, 5, 7 | 3 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) FH,2P,QSF | 2, 5, 7 | 3 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 2, 5, 7 | 3 |
| QLogic (NIC: 25 Gb) DP,SFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP | 2, 5, 7 | 3 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 2, 5, 7 | 3 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 2, 5, 7 | 3 |
| Mellanox (NIC: 25 Gb) FH,2P,S28,F1 | 2, 5, 7 | 3 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,FH | 2, 5, 7 | 3 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 2, 5, 7 | 3 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 2, 5, 7 | 3 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 2, 5, 7 | 3 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 2, 5, 7 | 3 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,4P,S28 | 2, 5, 7 | 3 |
| Broadcom (NIC: 25 Gb) FH,4P,S28 | 2, 5, 7 | 3 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 2, 5, 7 | 3 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 2, 5, 7 | 3 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 2, 5, 7 | 3 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 2, 5, 7 | 3 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 2, 5, 7 | 3 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 2, 5, 7 | 3 |
| Emulex (HBA: FC32) FH,1P,S28 | 2, 5, 7 | 3 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 2, 5, 7 | 3 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 2, 5, 7 | 3 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 2, 5, 7 | 3 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 2, 5, 7 | 3 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 2, 5, 7 | 3 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 2, 5, 7 | 3 |
| Emulex (HBA: FC16)1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31002 | 2, 5, 7 | 3 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 2, 5, 7 | 3 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 2, 5, 7 | 3 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 2, 5, 7 | 3 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,FH,V2 | 2, 5, 7 | 3 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 2, 5, 7 | 3 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,V2 | 2, 5, 7 | 3 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 2, 5, 7 | 3 |
| QLogic (NIC: 10 Gb) QP | 2, 5, 7 | 3 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 2, 5, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,V2 | 2, 5, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 2, 5, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 2, 5, 7 | 3 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 2, 5, 7 | 3 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 2, 5, 7 | 3 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 2, 5, 7 | 3 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 2, 5, 7 | 3 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 2, 5, 7 | 3 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 2, 5, 7 | 3 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 2, 5, 7 | 3 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 2, 5, 7 | 3 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 2, 5, 7 | 3 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML | 2, 5, 7 | 3 |
| Mellanox (NIC: HDR VPI) HDRV,1P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 | 2, 5, 7 | 3 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2,18F | 2, 5, 7 | 2 |
| FOXCONN (External Adapter) H840 FH,V3,18F | 2, 5, 7 | 2 |
| FOXCONN (External Adapter) H840 LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 2, 5, 7 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 2, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 2, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 2, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 2, 5, 7 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 2, 5, 7 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 2, 5, 7 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 2, 5, 7 | 5 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 2, 5, 7 | 5 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 2, 5, 7 | 5 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 2, 5, 7 | 5 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 2, 5, 7 | 5 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 2, 5, 7 | 5 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 2, 5, 7 | 5 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 2, 5, 7 | 5 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 2, 5, 7 | 5 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 2, 5, 7 | 5 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 2, 5, 7 | 5 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 2, 5, 7 | 5 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) SVR,15G | 4, 8 | 1 |
| FOXCONN (Front PERC) H755N | Internal slot | 2 |
| FOXCONN (Front PERC) H755N MXC | Internal slot | 2 |
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front PERC) H755 MXC | Internal slot | 1 |
| Inventec (Front PERC) H745 V3 | Internal slot | 1 |
| Inventec (Front PERC) H745 V2 | Internal slot | 1 |
| Inventec (Front PERC) H745 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 V2 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 | Internal slot | 1 |
| FOXCONN (Front PERC) H355 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i V2 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 4, 5, 1, 2, 7, 8 | 6 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 4, 5, 1, 2, 7 | 5 |
| QLogic (NIC: 25 Gb) DPSFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,25G,SFP | 4, 5, 1, 2, 7 | 5 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 4, 5, 1, 2, 7 | 5 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH | 4, 5, 1, 2, 7 | 5 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 4, 5, 1, 2, 7 | 5 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 4, 5, 1, 2, 7 | 5 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 4, 5, 1, 2, 7 | 5 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 4, 5, 1, 2, 7 | 5 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32 LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC32) FH,1P,S28 | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 4, 5, 1, 2, 7 | 5 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 4, 5, 1, 2, 7 | 5 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 4, 5, 1, 2, 7 | 5 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 4, 5, 1, 2, 7 | 5 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC16) 1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16 ) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16 ) 2P,LPE31002 | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 4, 5, 1, 2, 7 | 5 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 4, 5, 1, 2, 7 | 5 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 4, 5, 1, 2, 7 | 5 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) FH,DP,V2 | 4, 5, 1, 2, 7 | 5 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 4, 5, 1, 2, 7 | 5 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,V2 | 4, 5, 1, 2, 7 | 5 |
| QLogic (NIC: 10 Gb) DP,VT,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 4, 5, 1, 2, 7 | 5 |
| QLogic (NIC: 10 Gb) QP | 4, 5, 1, 2, 7 | 5 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 4, 5, 1, 2, 7 | 5 |
| Intel (NIC: 10 Gb) SFP+,V2 | 4, 5, 1, 2, 7 | 5 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 4, 5, 1, 2, 7 | 5 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 4, 5, 1, 2, 7 | 5 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 4, 5, 1, 2, 7 | 5 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 4, 5, 1, 2, 7 | 5 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 4, 5, 1, 2, 7 | 5 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 4, 5, 1, 2, 7 | 5 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 4, 5, 1, 2, 7 | 5 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 4, 5, 1, 2, 7 | 5 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 4, 5, 1, 2, 7 | 5 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 4, 5, 1, 2, 7 | 5 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 4, 5, 1, 2, 7 | 5 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | 3, 6 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2,18F | 4, 5, 1, 2, 7 | 2 |
| FOXCONN (External Adapter) H840 FH,V3,18F | 4, 5, 1, 2, 7 | 2 |
| FOXCONN (External Adapter) H840 LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 4, 5, 1, 2, 7 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 4, 5, 1, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 4, 5, 1, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 4, 5, 1, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 4, 5, 1, 2, 7 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 4, 5, 1, 2, 7, 8 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 4, 5, 1, 2, 7, 8 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 4, 5, 1, 2, 7, 8 | 8 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) FH,SVR,15G | 4, 8 | 1 |
| NVIDIA (GPU) T4,16 Gb,70W,V2 | 1, 2, 7, 8 | 4 |
| NVIDIA (GPU) T4,16 Gb,70W,L | 3, 6 | 2 |
| NVIDIA (GPU) A2,16 Gb,60 W | 1, 2, 7, 8 | 4 |
| NVIDIA (GPU) A2,16 Gb,V2 | 1, 2, 7, 8 | 4 |
| NVIDIA (GPU) A2,16 Gb,LP,V2 | 3, 6 | 2 |
| FOXCONN (PERC) H755,ADPT | 5, 3 | 1 |
| FOXCONN (PERC) H755,ADPT,MXC | 5, 3 | 1 |
| Inventec (PERC) H745,4 Gb,ADPT,V2 | 5, 3 | 1 |
| Inventec (PERC) H745,4 Gb,ADPT | 5, 3 | 1 |
| FOXCONN (PERC) H355,ADPT | 5, 3 | 1 |
| FOXCONN (PERC) H345,ADPT,V2 | 5, 3 | 1 |
| FOXCONN (PERC) H345,ADPT | 5, 3 | 1 |
| FOXCONN (PERC) HBA355i,ADPT | 5, 3 | 1 |
| FOXCONN (PERC) HBA355i,ADPT,V2 | 5, 3 | 1 |
| FOXCONN (PERC) HBA345,ADPT | 5, 3 | 1 |
| FOXCONN (PERC) HBA345,ADPT,V2 | 5, 3 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 1, 2, 5, 7, 8 | 5 |
| Mellanox (NIC: 100G) LP,2P,Q56 | 3, 6 | 2 |
| NAPATECH (NIC: 100 Gb) DP,QSFP28 | 1, 2, 5, 7 | 4 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSFP | 1, 2, 5, 7 | 4 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) FH,2P,Q28 | 1, 2, 5, 7 | 4 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) FH,2P,QSF | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 1, 2, 5, 7 | 4 |
| QLogic (NIC: 25 Gb) DP,SFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP | 1, 2, 5, 7 | 4 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 1, 2, 5, 7 | 4 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 1, 2, 5, 7 | 4 |
| Mellanox (NIC: 25 Gb) FH,2P,S28,F1 | 1, 2, 5, 7 | 4 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,FH | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 1, 2, 5, 7 | 4 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 1, 2, 5, 7 | 4 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,4P,S28 | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 25 Gb) FH,4P,S28 | 1, 2, 5, 7 | 4 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 1, 2, 5, 7 | 4 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC32) FH,1P,S28 | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 1, 2, 5, 7 | 4 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 1, 2, 5, 7 | 4 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 1, 2, 5, 7 | 4 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 1, 2, 5, 7 | 4 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC16)1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31002 | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 1, 2, 5, 7 | 4 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 1, 2, 5, 7 | 4 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 1, 2, 5, 7 | 4 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,FH,V2 | 1, 2, 5, 7 | 4 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 1, 2, 5, 7 | 4 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,V2 | 1, 2, 5, 7 | 4 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 1, 2, 5, 7 | 4 |
| QLogic (NIC: 10 Gb) QP | 1, 2, 5, 7 | 4 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 1, 2, 5, 7 | 4 |
| Intel (NIC: 10 Gb) SFP+,V2 | 1, 2, 5, 7 | 4 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 1, 2, 5, 7 | 4 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 1, 2, 5, 7 | 4 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 1, 2, 5, 7 | 4 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 1, 2, 5, 7 | 4 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 1, 2, 5, 7 | 4 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 1, 2, 5, 7 | 4 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML | 1, 2, 5, 7 | 4 |
| Mellanox (NIC: HDR VPI) HDRV,1P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 | 1, 2, 5, 7 | 4 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2,18F | 1, 2, 5, 7 | 2 |
| FOXCONN (External Adapter) H840 FH,V3,18F | 1, 2, 5, 7 | 2 |
| FOXCONN (External Adapter) H840 LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 1, 2, 5, 7 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 1, 2, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 1, 2, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 1, 2, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 1, 2, 5, 7 | 2 |
| Inventec (BOSS-S1) V4,SATA,FH | 1, 2, 5, 7, 8 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 1, 2, 5, 7, 8 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 1, 2, 5, 7, 8 | 7 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 1, 2, 5, 7, 8 | 7 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 1, 2, 5, 7, 8 | 7 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 1, 2, 5, 7, 8 | 7 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 1, 2, 5, 7, 8 | 7 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 1, 2, 5, 7, 8 | 7 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 1, 2, 5, 7, 8 | 7 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 1, 2, 5, 7, 8 | 7 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 1, 2, 5, 7, 8 | 7 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 1, 2, 5, 7, 8 | 7 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 1, 2, 5, 7, 8 | 7 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 1, 2, 5, 7, 8 | 7 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) FH,SVR,15G | 4 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 5, 4 | 2 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 5, 4 | 2 |
| QLogic (NIC: 25 Gb) DPSFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,25G,SFP | 5, 4 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 5, 4 | 2 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH | 5, 4 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 5, 4 | 2 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 5, 4 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 5, 4 | 2 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 5, 4 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 5, 4 | 2 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 5, 4 | 2 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 5, 4 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 5, 4 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32 LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 5, 4 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 5, 4 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 5, 4 | 2 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 5, 4 | 2 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 5, 4 | 2 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 5, 4 | 2 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 5, 4 | 2 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 5, 4 | 2 |
| Emulex (HBA: FC16) 1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16 ) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16 ) 2P,LPE31002 | 5, 4 | 2 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 5, 4 | 2 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 5, 4 | 2 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 5, 4 | 2 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) FH,DP,V2 | 5, 4 | 2 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 5, 4 | 2 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,V2 | 5, 4 | 2 |
| QLogic (NIC: 10 Gb) DP,VT,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 5, 4 | 2 |
| QLogic (NIC: 10 Gb) QP | 5, 4 | 2 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 5, 4 | 2 |
| Intel (NIC: 10 Gb) SFP+,V2 | 5, 4 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 5, 4 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 5, 4 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 5, 4 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 5, 4 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 5, 4 | 2 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 5, 4 | 2 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 5, 4 | 2 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 5, 4 | 2 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 5, 4 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 5, 4 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 5, 4 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | 3, 6 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2,18F | 5, 4 | 2 |
| FOXCONN (External Adapter) H840 FH,V3,18F | 5, 4 | 2 |
| FOXCONN (External Adapter) H840 LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 5, 4 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 5, 4 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 5, 4 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 5, 4 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 5, 4 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 5, 4 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 5, 4 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 5, 4 | 4 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 5, 4 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 5, 4 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 5, 4 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 5, 4 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 5, 4 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 5, 4 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 5, 4 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 5, 4 | 4 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 5, 4 | 4 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 5, 4 | 4 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 5, 4 | 4 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front) H755,MXC | Internal slot | 1 |
| Inventec (Front PERC)VH745,V3 | Internal slot | 1 |
| FOXCONN (Front PERC) H345,V2 | Internal slot | 1 |
| FOXCONN (Front PERC)H355 | Internal slot | 1 |
| FOXCONN (Front PERCHBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i,V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3 | 1 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) DP,QSF | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) SFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,2P,LPE35002 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 3, 6 | 2 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31002 | 3, 6 | 2 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) 1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,LP,V2 | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,LP,F1 | 3, 6 | 2 |
| Broadcom (NIC: 1 Gb) LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100) PCIe,CX6,SP,L,ML | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | 3, 6 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 LP,V2 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA FH | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA | 3, 6 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6 | 2 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6 | 2 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6 | 2 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6 | 2 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) FH,SVR,15G | 8 | 1 |
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front) H755,MXC | Internal slot | 1 |
| Inventec (Front PERC)VH745,V3 | Internal slot | 1 |
| FOXCONN (Front PERC) H345,V2 | Internal slot | 1 |
| FOXCONN (Front PERC)H355 | Internal slot | 1 |
| FOXCONN (Front PERCHBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i,V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 2, 7 | 2 |
| Mellanox (NIC: 100G) LP,2P,Q56 | 3, 6 | 2 |
| NAPATECH (NIC: 100 Gb) DP,QSFP28 | 2, 7 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSFP | 2, 7 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) FH,2P,Q28 | 2, 7 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) FH,2P,QSF | 2, 7 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 2, 7 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP | 2, 7 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 2, 7 | 2 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 2, 7 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28,F1 | 2, 7 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,FH | 2, 7 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 2, 7 | 2 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 2, 7 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 2, 7 | 2 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 2, 7 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,4P,S28 | 2, 7 | 2 |
| Broadcom (NIC: 25 Gb) FH,4P,S28 | 2, 7 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 2, 7 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 2, 7 | 2 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 2, 7 | 2 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 2, 7 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 2, 7 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 2, 7 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 2, 7 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 2, 7 | 2 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 2, 7 | 2 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 2, 7 | 2 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 2, 7 | 2 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 2, 7 | 2 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 2, 7 | 2 |
| Emulex (HBA: FC16)1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31002 | 2, 7 | 2 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 2, 7 | 2 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 2, 7 | 2 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 2, 7 | 2 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,FH,V2 | 2, 7 | 2 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 2, 7 | 2 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,V2 | 2, 7 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 2, 7 | 2 |
| QLogic (NIC: 10 Gb) QP | 2, 7 | 2 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 2, 7 | 2 |
| Intel (NIC: 10 Gb) SFP+,V2 | 2, 7 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 2, 7 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 2, 7 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 2, 7 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 2, 7 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 2, 7 | 2 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 2, 7 | 2 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 2, 7 | 2 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 2, 7 | 2 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 2, 7 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 2, 7 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 2, 7 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML | 2, 7 | 2 |
| Mellanox (NIC: HDR VPI) HDRV,1P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 | 2, 7 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2,18F | 2, 7 | 2 |
| FOXCONN (External Adapter) H840 FH,V3,18F | 2, 7 | 2 |
| FOXCONN (External Adapter) H840 LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 2, 7 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 2, 7 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 2, 7 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 2, 7 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 2, 7 | 4 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 2, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 2, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 2, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 2, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 2, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 2, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 2, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 2, 7 | 4 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 2, 7 | 4 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 2, 7 | 4 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 2, 7 | 4 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) FH,SVR,15G | 8 | 1 |
| FOXCONN (Front PERC ASSY,CRD,CTL,H755,FRONT | Internal slot | 1 |
| FOXCONN (Front PERC ASSY,CRD,CTL,H755,FRT,MXC | Internal slot | 1 |
| Inventec (Front PERC ASSY,CRD,CTL,H745,4 Gb,FPERC,V3 | Internal slot | 1 |
| FOXCONN (Front PERC ASSY,CRD,CTL,H345,FPERC,V2 | Internal slot | 1 |
| FOXCONN (Front PERC ASSY,CRD,CTL,H355,FPERC | Internal slot | 1 |
| FOXCONN (Front PERC PWA,CTL,HBA355I,FRONT | Internal slot | 1 |
| FOXCONN (Front PERC PWA,CTL,HBA355I,FRONT,V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 1, 2, 7, 8 | 4 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 1, 2, 7 | 3 |
| QLogic (NIC: 25 Gb) DPSFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,25G,SFP | 1, 2, 7 | 3 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 1, 2, 7 | 3 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH | 1, 2, 7 | 3 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 1, 2, 7 | 3 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 1, 2, 7 | 3 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 1, 2, 7 | 3 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 1, 2, 7 | 3 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 1, 2, 7 | 3 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32 LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) FH,1P,S28 | 1, 2, 7 | 3 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 1, 2, 7 | 3 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 1, 2, 7 | 3 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 1, 2, 7 | 3 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 1, 2, 7 | 3 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 1, 2, 7 | 3 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 1, 2, 7 | 3 |
| Emulex (HBA: FC16) 1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16 ) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16 ) 2P,LPE31002 | 1, 2, 7 | 3 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 1, 2, 7 | 3 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 1, 2, 7 | 3 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 1, 2, 7 | 3 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) FH,DP,V2 | 1, 2, 7 | 3 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 1, 2, 7 | 3 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,V2 | 1, 2, 7 | 3 |
| QLogic (NIC: 10 Gb) DP,VT,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 1, 2, 7 | 3 |
| QLogic (NIC: 10 Gb) QP | 1, 2, 7 | 3 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,V2 | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 1, 2, 7 | 3 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 1, 2, 7 | 3 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 1, 2, 7 | 3 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 1, 2, 7 | 3 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 1, 2, 7 | 3 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 1, 2, 7 | 3 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 1, 2, 7 | 3 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 1, 2, 7 | 3 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 1, 2, 7 | 3 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | 3, 6 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2,18F | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) H840 FH,V3,18F | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) H840 LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 1, 2, 7 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 1, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 1, 2, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 1, 2, 7 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 1, 2, 7, 8 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 1, 2, 7, 8 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 1, 2, 7, 8 | 6 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 1, 2, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 1, 2, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 1, 2, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 1, 2, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 1, 2, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 1, 2, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 1, 2, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 1, 2, 7, 8 | 6 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 1, 2, 7, 8 | 6 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 1, 2, 7, 8 | 6 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 1, 2, 7, 8 | 6 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) FH,SVR,15G | 8 | 1 |
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front PERC) H755,MXC | Internal slot | 1 |
| Inventec (Front PERC) H745,V3 | Internal slot | 1 |
| FOXCONN (Front PERC) H345,V2 | Internal slot | 1 |
| FOXCONN (Front PERC) H355 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i,V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 7, 8 | 2 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 7 | 1 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 7 | 1 |
| QLogic (NIC: 25 Gb) DPSFP,LP,V2 | 7 | 1 |
| Intel (NIC: 25 Gb) DP,25G,SFP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 7 | 1 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 7 | 1 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH | 7 | 1 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 | 7 | 1 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 7 | 1 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 7 | 1 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 7 | 1 |
| Emulex (HBA: FC64) LP,2P,S28 | 7 | 1 |
| Emulex (HBA: FC32) 2P,LPE35002 | 7 | 1 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32 LP,2P,V1.1 | 7 | 1 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 7 | 1 |
| Emulex (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 7 | 1 |
| Emulex (HBA: FC32) LP,1P,S28 | 7 | 1 |
| QLogic (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28 | 7 | 1 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 7 | 1 |
| QLogic (HBA: FC32) FH,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28 | 7 | 1 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 7 | 1 |
| Emulex (HBA: FC16) 1P,LPE31000 | 3, 6 | 2 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31K0,L | 7 | 1 |
| Emulex (HBA: FC16 ) LP,1P,SF+,F1 | 7 | 1 |
| Emulex (HBA: FC16 ) 2P,LPE31002 | 3, 6 | 2 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 7 | 1 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 7 | 1 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 7 | 1 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 7 | 1 |
| QLogic (HBA: FC16) FH,DP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 7 | 1 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,V2 | 7 | 1 |
| QLogic (NIC: 10 Gb) DP,VT,LP,V2 | 7 | 1 |
| QLogic (NIC: 10 Gb) SFP,QP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) QP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) QP,LP | 7 | 1 |
| Intel (NIC: 10 Gb) LP,V2 | 7 | 1 |
| Intel (NIC: 10 Gb) SFP+ | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 7 | 1 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 7 | 1 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 7 | 1 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 7 | 1 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 7 | 1 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 7 | 1 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 7 | 1 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 7 | 1 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 7 | 1 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 7 | 1 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 7 | 1 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 3, 6 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 3, 6 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | Internal slot | 1 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840,FH,V2,18F | 7 | 1 |
| FOXCONN (External Adapter) H840,FH,V3,18F | 7 | 1 |
| FOXCONN (External Adapter) H840,LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840,LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 7 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 7 | 1 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 7 | 1 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 7 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 7, 8 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 7, 8 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 7, 8 | 4 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 7, 8 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 7, 8 | 4 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 7, 8 | 4 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 7, 8 | 4 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 7, 8 | 4 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) FH,SVR,15G | 4, 8 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 4, 5, 7, 8 | 4 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 4, 5, 7 | 3 |
| QLogic (NIC: 25 Gb) DPSFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,25G,SFP | 4, 5, 7 | 3 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 4, 5, 7 | 3 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH | 4, 5, 7 | 3 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 4, 5, 7 | 3 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 4, 5, 7 | 3 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 4, 5, 7 | 3 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 4, 5, 7 | 3 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 4, 5, 7 | 3 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 4, 5, 7 | 3 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 4, 5, 7 | 3 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 4, 5, 7 | 3 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32 LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 4, 5, 7 | 3 |
| Emulex (HBA: FC32) FH,1P,S28 | 4, 5, 7 | 3 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 4, 5, 7 | 3 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 4, 5, 7 | 3 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 4, 5, 7 | 3 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 4, 5, 7 | 3 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 4, 5, 7 | 3 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 4, 5, 7 | 3 |
| Emulex (HBA: FC16) 1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16 ) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16 ) 2P,LPE31002 | 4, 5, 7 | 3 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 4, 5, 7 | 3 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 4, 5, 7 | 3 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 4, 5, 7 | 3 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) FH,DP,V2 | 4, 5, 7 | 3 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 4, 5, 7 | 3 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,V2 | 4, 5, 7 | 3 |
| QLogic (NIC: 10 Gb) DP,VT,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 4, 5, 7 | 3 |
| QLogic (NIC: 10 Gb) QP | 4, 5, 7 | 3 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 4, 5, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,V2 | 4, 5, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 4, 5, 7 | 3 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 4, 5, 7 | 3 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 4, 5, 7 | 3 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 4, 5, 7 | 3 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 4, 5, 7 | 3 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 4, 5, 7 | 3 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 4, 5, 7 | 3 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 4, 5, 7 | 3 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 4, 5, 7 | 3 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 4, 5, 7 | 3 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 4, 5, 7 | 3 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | 3, 6 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840,FH,V2,18F | 4, 5, 7 | 2 |
| FOXCONN (External Adapter) H840,FH,V3,18F | 4, 5, 7 | 2 |
| FOXCONN (External Adapter) H840,LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840,LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 4, 5, 7 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 4, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 4, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 4, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 4, 5, 7 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 4, 5, 7, 8 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 4, 5, 7, 8 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 4, 5, 7, 8 | 6 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 4, 5, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 4, 5, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 4, 5, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 4, 5, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 4, 5, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 4, 5, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 4, 5, 7, 8 | 6 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 4, 5, 7, 8 | 6 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 4, 5, 7, 8 | 6 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 4, 5, 7, 8 | 6 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 4, 5, 7, 8 | 6 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Xilinx (Accelerators - FPGAs) 225 W,PSV,FH | 5, 7 | 2 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31K0,EM,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) LP,10G,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) LP,F1 | 3, 6 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | 3, 6 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 LP,V2 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA FH | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA | 3, 6 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6 | 2 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6 | 2 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6 | 2 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6 | 2 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial) SVR,15G | 4, 8 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 5, 7 | 2 |
| Mellanox (NIC: 100G) LP,2P,Q56 | 3, 6 | 2 |
| NAPATECH (NIC: 100 Gb) DP,QSFP28 | 5, 7 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSFP | 5, 7 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) FH,2P,Q28 | 5, 7 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) FH,2P,QSF | 5, 7 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 5, 7 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP | 5, 7 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 5, 7 | 2 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 5, 7 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28,F1 | 5, 7 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,FH | 5, 7 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 5, 7 | 2 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 5, 7 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 5, 7 | 2 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 5, 7 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,4P,S28 | 5, 7 | 2 |
| Broadcom (NIC: 25 Gb) FH,4P,S28 | 5, 7 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 5, 7 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 5, 7 | 2 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 5, 7 | 2 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 5, 7 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 5, 7 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 5, 7 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 5, 7 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 5, 7 | 2 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 5, 7 | 2 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 5, 7 | 2 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 5, 7 | 2 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 5, 7 | 2 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 5, 7 | 2 |
| Emulex (HBA: FC16)1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31002 | 5, 7 | 2 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 5, 7 | 2 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 5, 7 | 2 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 5, 7 | 2 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,FH,V2 | 5, 7 | 2 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 5, 7 | 2 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,V2 | 5, 7 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 5, 7 | 2 |
| QLogic (NIC: 10 Gb) QP | 5, 7 | 2 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 5, 7 | 2 |
| Intel (NIC: 10 Gb) SFP+,V2 | 5, 7 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 5, 7 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 5, 7 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 5, 7 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 5, 7 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 5, 7 | 2 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 5, 7 | 2 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 5, 7 | 2 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 5, 7 | 2 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 5, 7 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 5, 7 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 5, 7 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML | 5, 7 | 2 |
| Mellanox (NIC: HDR VPI) HDRV,1P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 | 5, 7 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840,FH,V2,18F | 5, 7 | 2 |
| FOXCONN (External Adapter) H840,FH,V3,18F | 5, 7 | 2 |
| FOXCONN (External Adapter) H840,LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840,LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 5, 7 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 5, 7 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 5, 7 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 5, 7 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 5, 7 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 5, 7 | 4 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 5, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 5, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 5, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 5, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 5, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 5, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 5, 7 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 5, 7 | 4 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 5, 7 | 4 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 5, 7 | 4 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 5, 7 | 4 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| FOXCONN (Front PERC) H755N | Internal slot | 2 |
| FOXCONN (Front PERC) H755N MXC | Internal slot | 2 |
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front PERC) H755 MXC | Internal slot | 1 |
| Inventec (Front PERC) H745 V3 | Internal slot | 1 |
| Inventec (Front PERC) H745 V2 | Internal slot | 1 |
| Inventec (Front PERC) H745 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 V2 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 | Internal slot | 1 |
| FOXCONN (Front PERC) H355 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i V2 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3 | 1 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) DP,QSF | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) SFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,2P,LPE35002 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 3, 6 | 2 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31002 | 3, 6 | 2 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) 1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,LP,V2 | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,LP,F1 | 3, 6 | 2 |
| Broadcom (NIC: 1 Gb) LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100) PCIe,CX6,SP,L,ML | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | 3, 6 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 LP,V2 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA FH | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb SAS-HBA | 3, 6 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6 | 2 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6 | 2 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6 | 2 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6 | 2 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6 | 2 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial ASSY,CRD,SER,FH,SVR,15G | 4 | 1 |
| FOXCONN (Front PERC) H755N | Internal slot | 2 |
| FOXCONN (Front PERC) H755N MXC | Internal slot | 2 |
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front PERC) H755 MXC | Internal slot | 1 |
| Inventec (Front PERC) H745 V3 | Internal slot | 1 |
| Inventec (Front PERC) H745 V2 | Internal slot | 1 |
| Inventec (Front PERC) H745 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 V2 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 | Internal slot | 1 |
| FOXCONN (Front PERC) H355 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i V2 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 2, 5 | 2 |
| Mellanox (NIC: 100G) LP,2P,Q56 | 3, 6 | 2 |
| NAPATECH (NIC: 100 Gb) DP,QSFP28 | 2, 5 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSFP | 2, 5 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) FH,2P,Q28 | 2, 5 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) FH,2P,QSF | 2, 5 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 2, 5 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,SFP | 2, 5 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 2, 5 | 2 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 2, 5 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28,F1 | 2, 5 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) DP,57414,FH | 2, 5 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 2, 5 | 2 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 2, 5 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 2, 5 | 2 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 2, 5 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,4P,S28 | 2, 5 | 2 |
| Broadcom (NIC: 25 Gb) FH,4P,S28 | 2, 5 | 2 |
| Mellanox (NIC: 25 Gb) FH,2P,S28 | 2, 5 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 2, 5 | 2 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 2, 5 | 2 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 2, 5 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 2, 5 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 2, 5 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 2, 5 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 2, 5 | 2 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 2, 5 | 2 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 2, 5 | 2 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 2, 5 | 2 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 2, 5 | 2 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 2, 5 | 2 |
| Emulex (HBA: FC16)1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 2P,LPE31002 | 2, 5 | 2 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 2, 5 | 2 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 2, 5 | 2 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 2, 5 | 2 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) DP,2692,FH,V2 | 2, 5 | 2 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 2, 5 | 2 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,V2 | 2, 5 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 2, 5 | 2 |
| QLogic (NIC: 10 Gb) QP | 2, 5 | 2 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 2, 5 | 2 |
| Intel (NIC: 10 Gb) SFP+,V2 | 2, 5 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 2, 5 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 2, 5 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 2, 5 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 2, 5 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 2, 5 | 2 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 2, 5 | 2 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 2, 5 | 2 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 2, 5 | 2 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 2, 5 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 2, 5 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 2, 5 | 2 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML | 2, 5 | 2 |
| Mellanox (NIC: HDR VPI) HDRV,1P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 | 2, 5 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2,18F | 2, 5 | 2 |
| FOXCONN (External Adapter) H840 FH,V3,18F | 2, 5 | 2 |
| FOXCONN (External Adapter) H840 LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 2, 5 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 2, 5 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 2, 5 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 2, 5 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 2, 5 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 2, 5 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 2, 5 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 2, 5 | 4 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 2, 5 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 2, 5 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 2, 5 | 4 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 2, 5 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 2, 5 | 4 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 2, 5 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 2, 5 | 4 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 2, 5 | 4 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 2, 5 | 4 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 2, 5 | 4 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 2, 5 | 4 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Inventec (Serial ASSY,CRD,SER,FH,SVR,15G | 4 | 1 |
| FOXCONN (Front PERC) H755N | Internal slot | 2 |
| FOXCONN (Front PERC) H755N MXC | Internal slot | 2 |
| FOXCONN (Front PERC) H755 | Internal slot | 1 |
| FOXCONN (Front PERC) H755 MXC | Internal slot | 1 |
| Inventec (Front PERC) H745 V3 | Internal slot | 1 |
| Inventec (Front PERC) H745 V2 | Internal slot | 1 |
| Inventec (Front PERC) H745 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 V2 | Internal slot | 1 |
| FOXCONN (Front PERC) H345 | Internal slot | 1 |
| FOXCONN (Front PERC) H355 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i | Internal slot | 1 |
| FOXCONN (Front PERC) HBA355i V2 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 | Internal slot | 1 |
| FOXCONN (Front PERC) HBA345 V2 | Internal slot | 1 |
| FOXCONN (PERC Adapter) H755 | 3 | 1 |
| FOXCONN (PERC Adapter) H755 MXC | 3 | 1 |
| Inventec (PERC Adapter) H745 V2 | 3 | 1 |
| Inventec (PERC Adapter) H745 | 3 | 1 |
| FOXCONN (PERC Adapter) H355 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 V2 | 3 | 1 |
| FOXCONN (PERC Adapter) H345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i | 3 | 1 |
| FOXCONN (PERC Adapter) HBA355i V2 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 | 3 | 1 |
| FOXCONN (PERC Adapter) HBA345 V2 | 3 | 1 |
| Mellanox (NIC: 100 Gb) FH,2P,Q56 | 4, 5, 1, 2 | 4 |
| Mellanox (NIC: 100 Gb) LP,2P,Q56 | 3, 6 | 2 |
| Mellanox (NIC: 100 Gb) CX5,DP,QSF,L | 3, 6 | 2 |
| Intel (NIC: 100 Gb) LP,2P,Q28 | 3, 6 | 2 |
| Broadcom (NIC: 100 Gb) LP,2P,QSF | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) DP,SFP,V2 | 4, 5, 1, 2 | 4 |
| QLogic (NIC: 25 Gb) DPSFP,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) DP,25G,SFP | 4, 5, 1, 2 | 4 |
| Intel (NIC: 25 Gb) FH,2P,S28,F1 | 4, 5, 1, 2 | 4 |
| Intel (NIC: 25 Gb) DP,SFP,LP | 3, 6 | 2 |
| Intel (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28,F1 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH | 4, 5, 1, 2 | 4 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 | 4, 5, 1, 2 | 4 |
| Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 | 4, 5, 1, 2 | 4 |
| Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 | 3, 6 | 2 |
| Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 | 3, 6 | 2 |
| QLogic (NIC: 25 Gb) FH,2P,S28 | 4, 5, 1, 2 | 4 |
| QLogic (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Intel (NIC: 25 Gb) FH,2P,S28 | 4, 5, 1, 2 | 4 |
| Intel (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Mellanox (NIC: 25 Gb) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC64) FH,2P,S28 | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC64) LP,2P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002 | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC32) FH,2P,V1.1 | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC32) 2P,LPE35002,FH | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC32) 2P,LPE35002,L | 3, 6 | 2 |
| Emulex (HBA: FC32 LP,2P,V1.1 | 3, 6 | 2 |
| Emulex (HBA: FC32) 2P,LPE35002,LP | 3, 6 | 2 |
| Emulex (HBA: FC32) FH,1P,S28 | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC32) FH,1P,S28 | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| Emulex (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,1P,S28 | 4, 5, 1, 2 | 4 |
| QLogic (HBA: FC32) FH,1P,S28,F1 | 4, 5, 1, 2 | 4 |
| QLogic (HBA: FC32) LP,1P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC32) FH,2P,S28 | 4, 5, 1, 2 | 4 |
| QLogic (HBA: FC32) FH,2P,S28,F1 | 4, 5, 1, 2 | 4 |
| QLogic (HBA: FC32) LP,2P,S28 | 3, 6 | 2 |
| QLogic (HBA: FC32) LP,2P,S28,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16) 1P,LPE31000 | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC16) FH,1P,SF+,F1 | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC16) 1P,LPE31K0,L | 3, 6 | 2 |
| Emulex (HBA: FC16 ) LP,1P,SF+,F1 | 3, 6 | 2 |
| Emulex (HBA: FC16 ) 2P,LPE31002 | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC16) FH,2P,SF+,F1 | 4, 5, 1, 2 | 4 |
| Emulex (HBA: FC16) 2P,LPE31K2,L | 3, 6 | 2 |
| Emulex (HBA: FC16) LP,2P,SF+,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) SP,2690,FH,V2 | 4, 5, 1, 2 | 4 |
| QLogic (HBA: FC16) FH,1P,S28,F1 | 4, 5, 1, 2 | 4 |
| QLogic (HBA: FC16) SP,2690,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,1P,S28,F1 | 3, 6 | 2 |
| QLogic (HBA: FC16) FH,DP,V2 | 4, 5, 1, 2 | 4 |
| QLogic (HBA: FC16) FH,2P,S28,F1 | 4, 5, 1, 2 | 4 |
| QLogic (HBA: FC16) DP,2692,LP,V2 | 3, 6 | 2 |
| QLogic (HBA: FC16) LP,2P,S28,F1 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) DP,BT,V2 | 4, 5, 1, 2 | 4 |
| QLogic (NIC: 10 Gb) DP,VT,LP,V2 | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) SFP,QP | 4, 5, 1, 2 | 4 |
| QLogic (NIC: 10 Gb) QP | 4, 5, 1, 2 | 4 |
| QLogic (NIC: 10 Gb) QP,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+ | 4, 5, 1, 2 | 4 |
| Intel (NIC: 10 Gb) SFP+,V2 | 4, 5, 1, 2 | 4 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 | 3, 6 | 2 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL | 4, 5, 1, 2 | 4 |
| Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 | 4, 5, 1, 2 | 4 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH | 4, 5, 1, 2 | 4 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH | 4, 5, 1, 2 | 4 |
| Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP | 3, 6 | 2 |
| QLogic (NIC: 10 Gb) FH,2P,BT | 4, 5, 1, 2 | 4 |
| QLogic (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,4P,BT | 4, 5, 1, 2 | 4 |
| Intel (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 10 Gb) FH,2P,BT | 4, 5, 1, 2 | 4 |
| Intel (NIC: 10 Gb) LP,2P,BT | 3, 6 | 2 |
| Broadcom (NIC: 10 Gb) FH,4P,BT | 4, 5, 1, 2 | 4 |
| Broadcom (NIC: 10 Gb) LP,4P,BT | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,V3 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,LP,F1 | 3, 6 | 2 |
| Intel (NIC: 1 Gb) PCIe,QP,V3 | 4, 5, 1, 2 | 4 |
| Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 | 4, 5, 1, 2 | 4 |
| Broadcom (NIC: 1 Gb) PCIe,QP,V2 | 4, 5, 1, 2 | 4 |
| Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 | 3, 6 | 2 |
| Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L | 3, 6 | 2 |
| Mellanox (NIC: HDR VPI) LP,1P,Q56 | 3, 6 | 2 |
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| FOXCONN (External Adapter) H840 FH,V2,18F | 4, 5, 1, 2 | 2 |
| FOXCONN (External Adapter) H840 FH,V3,18F | 4, 5, 1, 2 | 2 |
| FOXCONN (External Adapter) H840 LP,V2,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 LP,V3,18 | 3, 6 | 2 |
| FOXCONN (External Adapter) H840 | 3, 6, 4, 5, 1, 2 | 2 |
| FOXCONN (External Adapter) HBA355e | 3, 6, 4, 5, 1, 2 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA FH | 4, 5, 1, 2 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH | 4, 5, 1, 2 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF | 3, 6 | 2 |
| FOXCONN (External Adapter) 12 Gb-SAS-HBA | 3, 6, 4, 5, 1, 2 | 2 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
| Inventec (BOSS-S1) V4,SATA,FH | 4, 5, 1, 2 | 1 |
| Inventec (BOSS-S1) V4,SATA,LP | 3, 6 | 1 |
| Inventec (BOSS-S1) V5,SATA,FH | 4, 5, 1, 2 | 1 |
| Inventec (BOSS-S1) V5,SATA,LP | 3, 6 | 1 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B | 3, 6, 4, 5, 1, 2 | 6 |
| SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B | 3, 6, 4, 5, 1, 2 | 6 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B | 3, 6, 4, 5, 1, 2 | 6 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 | 3, 6, 4, 5, 1, 2 | 6 |
| SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O | 3, 6, 4, 5, 1, 2 | 6 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 | 3, 6, 4, 5, 1, 2 | 6 |
| SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O | 3, 6, 4, 5, 1, 2 | 6 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 | 3, 6, 4, 5, 1, 2 | 6 |
| SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O | 3, 6, 4, 5, 1, 2 | 6 |
| Intel (PCIe SSD) NVMe,750 Gb,P4800X | 3, 6, 4, 5, 1, 2 | 6 |
| Intel (PCIe SSD) NVMe,375 Gb,P4800X | 3, 6, 4, 5, 1, 2 | 6 |
| Intel (PCIe SSD) PCIe,375 Gb,P4800X | 3, 6, 4, 5, 1, 2 | 6 |
| Card type | Slot priority | Maximum number of cards |
|---|---|---|
| Broadcom (OCP: 25 Gb) 2P,V2 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Broadcom (OCP: 25 Gb)4P,V2 | Internal slot | 1 |
| QLogic (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| SolarFlare (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 25 Gb) 4P,S28 | Internal slot | 1 |
| Mellanox (OCP: 25 Gb) 2P,S28 | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Broadcom (OCP: 10 Gb) 2P,V2 | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 2P,SF+ | Internal slot | 1 |
| Intel (OCP: 10 Gb) 2P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,BT | Internal slot | 1 |
| QLogic (OCP: 10 Gb) 4P,SF+ | Internal slot | 1 |
| Broadcom (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Intel (OCP: 1 Gb) 4P,BT | Internal slot | 1 |
| Inventec (BOSS-S2) 15G | Internal slot | 1 |
| Inventec (BOSS-S2) V2,15G | Internal slot | 1 |
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\