The following table describes the supported expansion cards:

Table 1. Expansion card riser configurationsThe table provides information about the expansion card riser configuration:
Expansion card riser PCIe slots Processor connection Height Length Slot width
Riser 1 Slot 1 Processor 1 Full Height (FH) Half Length (HL) x8
x16
Slot 2 x8
x16
Riser 2 Slot 3 Processor 1 Low Profile (LP) Half Length (HL) x16
Slot 6 Processor 2
Riser 3 Slot 4 Processor 2 Full Height (FH) Half Length (HL) x8
Slot 5 x16
Riser 4 Slot 7 Processor 2 Full Height (FH) Half Length (HL) x8
x16
x8
Slot 8 x16
Table 2. PCIe Riser Configs PCIe Riser Configs
Config # RSR Configuration # of CPUs PERC type supported Rear Storage Possible x8 CPU 1 x16 CPU 1 x8 CPU 2 x16 CPU 2
0 NO RSR 2 None No 0 0 0 0
1 R1B 1 Front PERC No 2 0 0 0
2 R1B+R4B 2 Front PERC/PERC Adapter No 2 0 2 0
3-1 R1A+R2A+R3A+R4A (FL) 2 Front PERC/PERC Adapter No 0 2 0 3
3-2 R1A+R2A+R3A+R4A (HL) 2 Front PERC/PERC Adapter No 0 2 0 3
4 R1B+R2A+R3B+R4B 2 Front PERC/PERC Adapter No 2 1 4 1
6 R1C+R2A+R3A+R4C 2 PERC Adapter No 0 3 0 4
7 R1D+R2A+R3B+R4D 2 None No 0 1 2 1
8-1 R1A+R2A+R4A (FL) 2 PERC Adapter Yes 0 2 0 2
8-2 R1A+R2A+R4A (HL) 2 PERC Adapter Yes 0 2 0 2
9 R1B+R2A+R4B 2 PERC Adapter Yes 2 1 2 1
10 R2A+R4B 2 PERC Adapter Yes 0 1 2 1
11 R1D+R2A+R3B+R4B 2 None No 0 1 4 1
12-1 R1D+R2A+R3A+R4A (FL) 2 None No 0 1 0 3
12-2 R1D+R2A+R3A+R4A (HL) 2 None No 0 1 0 3
13-1 R1A+R2A+R3A (FL) 2 Front PERC/PERC Adapter No 0 2 0 2
13-2 R1A+R2A+R3A (HL) 2 Front PERC/PERC Adapter No 0 2 0 2
14 R1B+R2A+R3B 2 Front PERC/PERC Adapter No 2 1 2 1
15 R1D+R4D 1 None No 0 0 0 0
NOTE:The expansion-card slots are not hot-swappable.

The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be installed in the card priority and slot priority order.

Table 3. Configuration 0 - No riserNo riser configuration.
Card type Slot priority Maximum number of cards
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
Inventec (BOSS-S2) ADPT,15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Table 4. Configuration 1: R1BRiser configuration R1B.
Card type Slot priority Maximum number of cards
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front PERC) H755 MXC Internal slot 1
Inventec (Front PERC) H745 V3 Internal slot 1
Inventec (Front PERC) H745 V2 Internal slot 1
Inventec (Front PERC) H745 Internal slot 1
FOXCONN (Front PERC) H345 V2 Internal slot 1
FOXCONN (Front PERC) H345 Internal slot 1
FOXCONN (Front PERC) H355 Internal slot 1
FOXCONN (Front PERC) HBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i V2 Internal slot 1
FOXCONN (Front PERC) HBA345 Internal slot 1
FOXCONN (Front PERC) HBA345 V2 Internal slot 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 1, 2 2
QLogic (NIC: 25 Gb) DP,SFP,V2 1, 2 2
Intel (NIC: 25 Gb) DP,SFP 1, 2 2
Intel (NIC: 25 Gb) FH,2P,S28,F1 1, 2 2
Broadcom (NIC: 25 Gb) DP,57414,FH 1, 2 2
Broadcom (NIC: 25 Gb) DP,57414,FH2 1, 2 2
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 1, 2 2
QLogic (NIC: 25 Gb) FH,2P,S28 1, 2 2
Intel (NIC: 25 Gb) FH,2P,S28 1, 2 2
Emulex (HBA: FC64) FH,2P,S28 1, 2 2
Emulex (HBA: FC32) 2P,LPE35002 1, 2 2
Emulex (HBA: FC32) FH,2P,V1.1 1, 2 2
Emulex (HBA: FC32) FH,2P,LPE35002 1, 2 2
Emulex (HBA: FC32) FH,1P,S28 1, 2 2
Emulex (HBA: FC32) FH,1P,S28 1, 2 2
QLogic (HBA: FC32) FH,1P,S28 1, 2 2
QLogic (HBA: FC32) FH,1P,S28,F1 1, 2 2
QLogic (HBA: FC32) FH,2P,S28 1, 2 2
QLogic (HBA: FC32) FH,2P,S28,F1 1, 2 2
Emulex (HBA: FC16) 1P,LPE31000 1, 2 2
Emulex (HBA: FC16) FH,1P,SF+,F1 1, 2 2
Emulex (HBA: FC16) 2P,LPE31002 1, 2 2
Emulex (HBA: FC16) FH,2P,SF+,F1 1, 2 2
QLogic (HBA: FC16) FH,SP,2690,V2 1, 2 2
QLogic (HBA: FC16) FH,1P,S28,F1 1, 2 2
QLogic (HBA: FC16) FH,DP,2692,V2 1, 2 2
QLogic (HBA: FC16) FH,2P,S28,F1 1, 2 2
QLogic (NIC: 10 Gb) DP,BT,V2 1, 2 2
QLogic (NIC: 10 Gb) SFP,QP 1, 2 2
QLogic (NIC: 10 Gb) QP 1, 2 2
Intel (NIC: 10 Gb) SFP+ 1, 2 2
Intel (NIC: 10 Gb) SFP+,V2 1, 2 2
Intel (NIC: 10 Gb) SFP+,DP 1, 2 2
Intel (NIC: 10 Gb) SFP+,DP 1, 2 2
Broadcom (NIC: 10 Gb) DP,57416,FH 1, 2 2
Broadcom (NIC: 10 Gb) DP,57412,FH 1, 2 2
QLogic (NIC: 10 Gb) FH,2P,BT 1, 2 2
Intel (NIC: 10 Gb) FH,4P,BT 1, 2 2
Intel (NIC: 10 Gb) FH,2P,BT 1, 2 2
Broadcom (NIC: 10 Gb) FH,4P,BT 1, 2 2
Intel (NIC: 1 Gb) QP,V3 1, 2 2
Intel (NIC: 1 Gb) QP,F1 1, 2 2
Broadcom (NIC: 1 Gb) QP,V2 1, 2 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2 1, 2 2
FOXCONN (External Adapter) H840 FH,V3 1, 2 2
FOXCONN (External Adapter) H840 1, 2 2
FOXCONN (External Adapter) HBA355e 1, 2 2
FOXCONN (External Adapter) 12 Gb SAS-HBA FH 1, 2 2
FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH 1, 2 2
FOXCONN (External Adapter) 12 Gb SAS-HBA 1, 2 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 1, 2 1
Inventec (BOSS-S1) V5,SATA,FH 1, 2 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 1, 2 2
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 1, 2 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 1, 2 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 1, 2 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 1, 2 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 1, 2 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 1, 2 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 1, 2 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 1, 2 2
Intel (PCIe SSD) NVMe,750 Gb,P4800X 1, 2 2
Intel (PCIe SSD) NVMe,375 Gb,P4800X 1, 2 2
Intel (PCIe SSD) PCIe,375 Gb,P4800X 1, 2 2
Table 5. Configuration 2: R1B+ R4BRiser configuration R1B+ R4B.
Card type Slot priority Maximum number of cards
Inventec (Serial) ASSY,CRD,SER,FH,SVR,15G 8 1
FOXCONN (Front PERC) H755N Internal slot 1
FOXCONN (Front PERC) H755N MXC Internal slot 1
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front PERC) H755 MXC Internal slot 1
Inventec (Front PERC) H745 V3 Internal slot 1
Inventec (Front PERC) H745 V2 Internal slot 1
Inventec (Front PERC) H745 Internal slot 1
FOXCONN (Front PERC) H345 V2 Internal slot 1
FOXCONN (Front PERC) H345 Internal slot 1
FOXCONN (Front PERC) H355 Internal slot 1
FOXCONN (Front PERC) HBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i V2 Internal slot 1
FOXCONN (Front PERC) HBA345 Internal slot 1
FOXCONN (Front PERC) HBA345 V2 Internal slot 1
FOXCONN (PERC Adapter) H755 2 1
FOXCONN (PERC Adapter) H755 MXC 2 1
Inventec (PERC Adapter) H745 V2 2 1
Inventec (PERC Adapter) H745 2 1
FOXCONN (PERC Adapter) H355 2 1
FOXCONN (PERC Adapter) H345 V2 2 1
FOXCONN (PERC Adapter) H345 2 1
FOXCONN (PERC Adapter) HBA355i 2 1
FOXCONN (PERC Adapter) HBA355i V2 2 1
FOXCONN (PERC Adapter) HBA345 2 1
FOXCONN (PERC Adapter) HBA345 V2 2 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 1, 2, 7, 8 4
QLogic (NIC: 25 Gb) DP,SFP,V2 1, 2, 7 3
Intel (NIC: 25 Gb) DP,SFP 1, 2, 7 3
Intel (NIC: 25 Gb) FH,2P,S28,F1 1, 2, 7 3
Broadcom (NIC: 25 Gb) DP,57414,FH 1, 2, 7 3
Broadcom (NIC: 25 Gb) DP,57414,FH2 1, 2, 7 3
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 1, 2, 7 3
QLogic (NIC: 25 Gb) FH,2P,S28 1, 2, 7 3
Intel (NIC: 25 Gb) FH,2P,S28 1, 2, 7 3
Emulex (HBA: FC64) FH,2P,S28 1, 2, 7 3
Emulex (HBA: FC32) 2P,LPE35002 1, 2, 7 3
Emulex (HBA: FC32) FH,2P,V1.1 1, 2, 7 3
Emulex (HBA: FC32) FH,2P,LPE35002 1, 2, 7 3
Emulex (HBA: FC32) FH,1P,S28 1, 2, 7 3
Emulex (HBA: FC32) FH,1P,S28 1, 2, 7 3
QLogic (HBA: FC32) FH,1P,S28 1, 2, 7 3
QLogic (HBA: FC32) FH,1P,S28,F1 1, 2, 7 3
QLogic (HBA: FC32) FH,2P,S28 1, 2, 7 3
QLogic (HBA: FC32) FH,2P,S28,F1 1, 2, 7 3
Emulex (HBA: FC16) 1P,LPE31000 1, 2, 7 3
Emulex (HBA: FC16) FH,1P,SF+,F1 1, 2, 7 3
Emulex (HBA: FC16) 2P,LPE31002 1, 2, 7 3
Emulex (HBA: FC16) FH,2P,SF+,F1 1, 2, 7 3
QLogic (HBA: FC16) FH,SP,2690,V2 1, 2, 7 3
QLogic (HBA: FC16) FH,1P,S28,F1 1, 2, 7 3
QLogic (HBA: FC16) FH,DP,2692,V2 1, 2, 7 3
QLogic (HBA: FC16) FH,2P,S28,F1 1, 2, 7 3
QLogic (NIC: 10 Gb) DP,BT,V2 1, 2, 7 3
QLogic (NIC: 10 Gb) SFP,QP 1, 2, 7 3
QLogic (NIC: 10 Gb) QP 1, 2, 7 3
Intel (NIC: 10 Gb) SFP+ 1, 2, 7 3
Intel (NIC: 10 Gb) SFP+,V2 1, 2, 7 3
Intel (NIC: 10 Gb) SFP+,DP 1, 2, 7 3
Intel (NIC: 10 Gb) SFP+,DP 1, 2, 7 3
Broadcom (NIC: 10 Gb) DP,57416,FH 1, 2, 7 3
Broadcom (NIC: 10 Gb) DP,57412,FH 1, 2, 7 3
QLogic (NIC: 10 Gb) FH,2P,BT 1, 2, 7 3
Intel (NIC: 10 Gb) FH,4P,BT 1, 2, 7 3
Intel (NIC: 10 Gb) FH,2P,BT 1, 2, 7 3
Broadcom (NIC: 10 Gb) FH,4P,BT 1, 2, 7 3
Intel (NIC: 1 Gb) QP,V3 1, 2, 7 3
Intel (NIC: 1 Gb) QP,F1 1, 2, 7 3
Broadcom (NIC: 1 Gb) QP,V2 1, 2, 7 3
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2 1, 2, 7 2
FOXCONN (External Adapter) H840 FH,V3 1, 2, 7 2
FOXCONN (External Adapter) H840 1, 2, 7 2
FOXCONN (External Adapter) HBA355e 1, 2, 7 2
FOXCONN (External Adapter) 12 Gb SAS-HBA FH 1, 2, 7 2
FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH 1, 2, 7 2
FOXCONN (External Adapter) 12 Gb SAS-HBA 1, 2, 7 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 1, 2, 7, 8 1
Inventec (BOSS-S1) V5,SATA,FH 1, 2, 7, 8 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 1, 2, 7, 8 4
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 1, 2, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 1, 2, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 1, 2, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 1, 2, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 1, 2, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 1, 2, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 1, 2, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 1, 2, 7, 8 4
Intel (PCIe SSD) NVMe,750 Gb,P4800X 1, 2, 7, 8 4
Intel (PCIe SSD) NVMe,375 Gb,P4800X 1, 2, 7, 8 4
Intel (PCIe SSD) PCIe,375 Gb,P4800X 1, 2, 7, 8 4
Table 6. Configuration 3-1: R1A + R2A + R3A + R4A (Full Length)Riser configuration R1A + R2A + R3A + R4A (FL).
Card type Slot priority Maximum number of cards
NVIDIA (GPU) T4,16 Gb,70W,L 3, 6 2
NVIDIA (GPU) A2,16 Gb,LP,V2 3, 6 2
NVIDIA (GPU) M10,32 Gb,225 W 2, 5, 7 3
NVIDIA (GPU) A100,40 Gb,250 W 2, 5, 7 3
NVIDIA (GPU) A10,24 Gb,150 W 2, 5, 7 3
NVIDIA (GPU) A10,24 Gb,V2 2, 5, 7 3
NVIDIA (GPU) A30,24 Gb,165 W 2, 5, 7 3
NVIDIA (GPU) A30,24 Gb,V2 2, 5, 7 3
NVIDIA (GPU) A40,48 Gb,300 W 2, 5, 7 3
NVIDIA (GPU) A40,48 Gb,V2 2, 5, 7 3
NVIDIA (GPU) V100,16 Gb,250 W 2, 5, 7 3
NVIDIA (GPU) V100S, 32 Gb,250 W,PCIe 2, 5, 7 3
AMD (GPU) MI100,32 Gb,300 W 2, 5, 7 3
AMD (GPU) MI210,64 Gb,300 W 2, 5, 7 3
NVIDIA (GPU) RTX6000, 24 Gb 2, 5, 7 3
NVIDIA (GPU) RTX8000, 40 Gb 2, 5, 7 3
NVIDIA (GPU) RTX5000, 16 Gb 2, 5, 7 3
NVIDIA (GPU) A16,64 Gb,250 W 2, 5, 7 3
NVIDIA (GPU) A16,64 Gb,V2 2, 5, 7 3
NVIDIA (GPU) A100,80 Gb,300 W 2, 5, 7 3
NVIDIA (GPU) A100,80 Gb,V2 2, 5, 7 3
Xilinx (Accelerators - FPGAs) XLNX,225 W,PSV,FH 2, 5, 7 3
FOXCONN (Front PERC) H755N Internal slot 2
FOXCONN (Front PERC) H755N MXC Internal slot 2
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front PERC) H755 MXC Internal slot 1
Inventec (Front PERC) H745 V3 Internal slot 1
Inventec (Front PERC) H745 V2 Internal slot 1
Inventec (Front PERC) H745 Internal slot 1
FOXCONN (Front PERC) H345 V2 Internal slot 1
FOXCONN (Front PERC) H345 Internal slot 1
FOXCONN (Front PERC) H355 Internal slot 1
FOXCONN (Front PERC) HBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i V2 Internal slot 1
FOXCONN (Front PERC) HBA345 Internal slot 1
FOXCONN (Front PERC) HBA345 V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 3 1
FOXCONN (PERC Adapter) HBA345 V2 3 1
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) DP,QSF 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) SFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) DP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 3, 6 2
Emulex (HBA: FC32) FH,2P,V1.1 3, 6 2
Emulex (HBA: FC32) FH,2P,LPE35002 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 3, 6 2
QLogic (HBA: FC32) FH,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 3, 6 2
Emulex (HBA: FC16) FH,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31002 3, 6 2
Emulex (HBA: FC16) FH,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) 1P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,LP,V2 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,LP,F1 3, 6 2
Broadcom (NIC: 1 Gb) LP,V2 3, 6 2
Mellanox (NIC: HDR100) PCIe,CX6,SP,L,ML 3, 6 2
Mellanox (NIC: HDR VPI) LP,1P,Q56 3, 6 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 LP,V2 3, 6 2
FOXCONN (External Adapter) H840 LP,V3 3, 6 2
FOXCONN (External Adapter) H840 3, 6 2
FOXCONN (External Adapter) HBA355e 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA FH 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA 3, 6 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6 2
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6 2
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6 2
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6 2
Table 7. Configuration 3-2: R1A + R2A + R3A + R4A (Half Length)Riser configuration R1A + R2A + R3A + R4A (HL).
Card type Slot priority Maximum number of cards
Inventec (Serial) SVR,15G 4, 8 1
NVIDIA (GPU) T4,16 Gb,70W,V2 2, 5, 7 3
NVIDIA (GPU) T4,16 Gb,70 W,L 3, 6 2
NVIDIA (GPU) A2,16 Gb,60 W 2, 5, 7 3
NVIDIA (GPU) A2,16 Gb,V2 2, 5, 7 3
NVIDIA (GPU) A2,16 Gb,LP,V2 3, 6 2
FOXCONN (Front PERC) H755N Internal slot 2
FOXCONN (Front PERC) H755N MXC Internal slot 2
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front PERC) H755 MXC Internal slot 1
Inventec (Front PERC) H745 V3 Internal slot 1
Inventec (Front PERC) H745 V2 Internal slot 1
Inventec (Front PERC) H745 Internal slot 1
FOXCONN (Front PERC) H345 V2 Internal slot 1
FOXCONN (Front PERC) H345 Internal slot 1
FOXCONN (Front PERC) H355 Internal slot 1
FOXCONN (Front PERC) HBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i V2 Internal slot 1
FOXCONN (Front PERC) HBA345 Internal slot 1
FOXCONN (Front PERC) HBA345 V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 3 1
FOXCONN (PERC Adapter) HBA345 V2 3 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 2, 5, 7 3
Mellanox (NIC: 100G) LP,2P,Q56 3, 6 2
NAPATECH (NIC: 100 Gb) DP,QSFP28 2, 5, 7 3
Mellanox (NIC: 100 Gb) CX5,DP,QSFP 2, 5, 7 3
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) FH,2P,Q28 2, 5, 7 3
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) FH,2P,QSF 2, 5, 7 3
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 2, 5, 7 3
QLogic (NIC: 25 Gb) DP,SFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,SFP 2, 5, 7 3
Intel (NIC: 25 Gb) FH,2P,S28,F1 2, 5, 7 3
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) FH,2P,S28 2, 5, 7 3
Mellanox (NIC: 25 Gb) FH,2P,S28,F1 2, 5, 7 3
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,FH 2, 5, 7 3
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 2, 5, 7 3
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 2, 5, 7 3
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 2, 5, 7 3
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 2, 5, 7 3
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,4P,S28 2, 5, 7 3
Broadcom (NIC: 25 Gb) FH,4P,S28 2, 5, 7 3
Mellanox (NIC: 25 Gb) FH,2P,S28 2, 5, 7 3
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 2, 5, 7 3
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 2, 5, 7 3
Emulex (HBA: FC32) FH,2P,V1.1 2, 5, 7 3
Emulex (HBA: FC32) 2P,LPE35002,FH 2, 5, 7 3
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32) LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 2, 5, 7 3
Emulex (HBA: FC32) FH,1P,S28 2, 5, 7 3
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 2, 5, 7 3
QLogic (HBA: FC32) FH,1P,S28,F1 2, 5, 7 3
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 2, 5, 7 3
QLogic (HBA: FC32) FH,2P,S28,F1 2, 5, 7 3
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 2, 5, 7 3
Emulex (HBA: FC16) FH,1P,SF+,F1 2, 5, 7 3
Emulex (HBA: FC16)1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31002 2, 5, 7 3
Emulex (HBA: FC16) FH,2P,SF+,F1 2, 5, 7 3
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 2, 5, 7 3
QLogic (HBA: FC16) FH,1P,S28,F1 2, 5, 7 3
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,FH,V2 2, 5, 7 3
QLogic (HBA: FC16) FH,2P,S28,F1 2, 5, 7 3
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,QLG,V2 2, 5, 7 3
QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 2, 5, 7 3
QLogic (NIC: 10 Gb) QP 2, 5, 7 3
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 2, 5, 7 3
Intel (NIC: 10 Gb) SFP+,V2 2, 5, 7 3
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 2, 5, 7 3
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 2, 5, 7 3
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 2, 5, 7 3
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 2, 5, 7 3
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 2, 5, 7 3
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 2, 5, 7 3
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 2, 5, 7 3
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 2, 5, 7 3
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 2, 5, 7 3
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 2, 5, 7 3
Broadcom (NIC: 1 Gb) PCIe,QP,V2 2, 5, 7 3
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML 2, 5, 7 3
Mellanox (NIC: HDR VPI) HDRV,1P,Q56 3, 6 2
Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 2, 5, 7 3
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2,18F 2, 5, 7 2
FOXCONN (External Adapter) H840 FH,V3,18F 2, 5, 7 2
FOXCONN (External Adapter) H840 LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840 LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 2, 5, 7 2
FOXCONN (External Adapter) HBA355e 3, 6, 2, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 2, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 2, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 2, 5, 7 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 2, 5, 7 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 2, 5, 7 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 2, 5, 7 5
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 2, 5, 7 5
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 2, 5, 7 5
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 2, 5, 7 5
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 2, 5, 7 5
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 2, 5, 7 5
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 2, 5, 7 5
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 2, 5, 7 5
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 2, 5, 7 5
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 2, 5, 7 5
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 2, 5, 7 5
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 2, 5, 7 5
Table 8. Configuration 4: R1B + R2A + R3B + R4B Riser configuration R1B + R2A + R3A + R4B.
Card type Slot priority Maximum number of cards
Inventec (Serial) SVR,15G 4, 8 1
FOXCONN (Front PERC) H755N Internal slot 2
FOXCONN (Front PERC) H755N MXC Internal slot 2
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front PERC) H755 MXC Internal slot 1
Inventec (Front PERC) H745 V3 Internal slot 1
Inventec (Front PERC) H745 V2 Internal slot 1
Inventec (Front PERC) H745 Internal slot 1
FOXCONN (Front PERC) H345 V2 Internal slot 1
FOXCONN (Front PERC) H345 Internal slot 1
FOXCONN (Front PERC) H355 Internal slot 1
FOXCONN (Front PERC) HBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i V2 Internal slot 1
FOXCONN (Front PERC) HBA345 Internal slot 1
FOXCONN (Front PERC) HBA345 V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 3 1
FOXCONN (PERC Adapter) HBA345 V2 3 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 4, 5, 1, 2, 7, 8 6
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 4, 5, 1, 2, 7 5
QLogic (NIC: 25 Gb) DPSFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,25G,SFP 4, 5, 1, 2, 7 5
Intel (NIC: 25 Gb) FH,2P,S28,F1 4, 5, 1, 2, 7 5
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH 4, 5, 1, 2, 7 5
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 4, 5, 1, 2, 7 5
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 4, 5, 1, 2, 7 5
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 4, 5, 1, 2, 7 5
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 4, 5, 1, 2, 7 5
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 4, 5, 1, 2, 7 5
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 4, 5, 1, 2, 7 5
Emulex (HBA: FC32) FH,2P,V1.1 4, 5, 1, 2, 7 5
Emulex (HBA: FC32) 2P,LPE35002,FH 4, 5, 1, 2, 7 5
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32 LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 4, 5, 1, 2, 7 5
Emulex (HBA: FC32) FH,1P,S28 4, 5, 1, 2, 7 5
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 4, 5, 1, 2, 7 5
QLogic (HBA: FC32) FH,1P,S28,F1 4, 5, 1, 2, 7 5
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 4, 5, 1, 2, 7 5
QLogic (HBA: FC32) FH,2P,S28,F1 4, 5, 1, 2, 7 5
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 4, 5, 1, 2, 7 5
Emulex (HBA: FC16) FH,1P,SF+,F1 4, 5, 1, 2, 7 5
Emulex (HBA: FC16) 1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16 ) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16 ) 2P,LPE31002 4, 5, 1, 2, 7 5
Emulex (HBA: FC16) FH,2P,SF+,F1 4, 5, 1, 2, 7 5
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 4, 5, 1, 2, 7 5
QLogic (HBA: FC16) FH,1P,S28,F1 4, 5, 1, 2, 7 5
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) FH,DP,V2 4, 5, 1, 2, 7 5
QLogic (HBA: FC16) FH,2P,S28,F1 4, 5, 1, 2, 7 5
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,V2 4, 5, 1, 2, 7 5
QLogic (NIC: 10 Gb) DP,VT,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 4, 5, 1, 2, 7 5
QLogic (NIC: 10 Gb) QP 4, 5, 1, 2, 7 5
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 4, 5, 1, 2, 7 5
Intel (NIC: 10 Gb) SFP+,V2 4, 5, 1, 2, 7 5
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 4, 5, 1, 2, 7 5
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 4, 5, 1, 2, 7 5
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 4, 5, 1, 2, 7 5
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 4, 5, 1, 2, 7 5
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 4, 5, 1, 2, 7 5
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 4, 5, 1, 2, 7 5
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 4, 5, 1, 2, 7 5
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 4, 5, 1, 2, 7 5
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 4, 5, 1, 2, 7 5
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 4, 5, 1, 2, 7 5
Broadcom (NIC: 1 Gb) PCIe,QP,V2 4, 5, 1, 2, 7 5
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR VPI) LP,1P,Q56 3, 6 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2,18F 4, 5, 1, 2, 7 2
FOXCONN (External Adapter) H840 FH,V3,18F 4, 5, 1, 2, 7 2
FOXCONN (External Adapter) H840 LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840 LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 4, 5, 1, 2, 7 2
FOXCONN (External Adapter) HBA355e 3, 6, 4, 5, 1, 2, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 4, 5, 1, 2, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 4, 5, 1, 2, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 4, 5, 1, 2, 7 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 4, 5, 1, 2, 7, 8 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 4, 5, 1, 2, 7, 8 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 4, 5, 1, 2, 7, 8 8
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 4, 5, 1, 2, 7, 8 8
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 4, 5, 1, 2, 7, 8 8
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 4, 5, 1, 2, 7, 8 8
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 4, 5, 1, 2, 7, 8 8
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 4, 5, 1, 2, 7, 8 8
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 4, 5, 1, 2, 7, 8 8
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 4, 5, 1, 2, 7, 8 8
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 4, 5, 1, 2, 7, 8 8
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 4, 5, 1, 2, 7, 8 8
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 4, 5, 1, 2, 7, 8 8
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 4, 5, 1, 2, 7, 8 8
Table 9. Configuration 6: R1C + R2A + R3A + R4CRiser configuration R1C + R2A + R3A + R4C.
Card type Slot priority Maximum number of cards
Inventec (Serial) FH,SVR,15G 4, 8 1
NVIDIA (GPU) T4,16 Gb,70W,V2 1, 2, 7, 8 4
NVIDIA (GPU) T4,16 Gb,70W,L 3, 6 2
NVIDIA (GPU) A2,16 Gb,60 W 1, 2, 7, 8 4
NVIDIA (GPU) A2,16 Gb,V2 1, 2, 7, 8 4
NVIDIA (GPU) A2,16 Gb,LP,V2 3, 6 2
FOXCONN (PERC) H755,ADPT 5, 3 1
FOXCONN (PERC) H755,ADPT,MXC 5, 3 1
Inventec (PERC) H745,4 Gb,ADPT,V2 5, 3 1
Inventec (PERC) H745,4 Gb,ADPT 5, 3 1
FOXCONN (PERC) H355,ADPT 5, 3 1
FOXCONN (PERC) H345,ADPT,V2 5, 3 1
FOXCONN (PERC) H345,ADPT 5, 3 1
FOXCONN (PERC) HBA355i,ADPT 5, 3 1
FOXCONN (PERC) HBA355i,ADPT,V2 5, 3 1
FOXCONN (PERC) HBA345,ADPT 5, 3 1
FOXCONN (PERC) HBA345,ADPT,V2 5, 3 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 1, 2, 5, 7, 8 5
Mellanox (NIC: 100G) LP,2P,Q56 3, 6 2
NAPATECH (NIC: 100 Gb) DP,QSFP28 1, 2, 5, 7 4
Mellanox (NIC: 100 Gb) CX5,DP,QSFP 1, 2, 5, 7 4
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) FH,2P,Q28 1, 2, 5, 7 4
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) FH,2P,QSF 1, 2, 5, 7 4
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 1, 2, 5, 7 4
QLogic (NIC: 25 Gb) DP,SFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,SFP 1, 2, 5, 7 4
Intel (NIC: 25 Gb) FH,2P,S28,F1 1, 2, 5, 7 4
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) FH,2P,S28 1, 2, 5, 7 4
Mellanox (NIC: 25 Gb) FH,2P,S28,F1 1, 2, 5, 7 4
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,FH 1, 2, 5, 7 4
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 1, 2, 5, 7 4
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 1, 2, 5, 7 4
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 1, 2, 5, 7 4
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 1, 2, 5, 7 4
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,4P,S28 1, 2, 5, 7 4
Broadcom (NIC: 25 Gb) FH,4P,S28 1, 2, 5, 7 4
Mellanox (NIC: 25 Gb) FH,2P,S28 1, 2, 5, 7 4
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 1, 2, 5, 7 4
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 1, 2, 5, 7 4
Emulex (HBA: FC32) FH,2P,V1.1 1, 2, 5, 7 4
Emulex (HBA: FC32) 2P,LPE35002,FH 1, 2, 5, 7 4
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32) LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 1, 2, 5, 7 4
Emulex (HBA: FC32) FH,1P,S28 1, 2, 5, 7 4
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 1, 2, 5, 7 4
QLogic (HBA: FC32) FH,1P,S28,F1 1, 2, 5, 7 4
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 1, 2, 5, 7 4
QLogic (HBA: FC32) FH,2P,S28,F1 1, 2, 5, 7 4
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 1, 2, 5, 7 4
Emulex (HBA: FC16) FH,1P,SF+,F1 1, 2, 5, 7 4
Emulex (HBA: FC16)1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31002 1, 2, 5, 7 4
Emulex (HBA: FC16) FH,2P,SF+,F1 1, 2, 5, 7 4
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 1, 2, 5, 7 4
QLogic (HBA: FC16) FH,1P,S28,F1 1, 2, 5, 7 4
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,FH,V2 1, 2, 5, 7 4
QLogic (HBA: FC16) FH,2P,S28,F1 1, 2, 5, 7 4
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,QLG,V2 1, 2, 5, 7 4
QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 1, 2, 5, 7 4
QLogic (NIC: 10 Gb) QP 1, 2, 5, 7 4
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 1, 2, 5, 7 4
Intel (NIC: 10 Gb) SFP+,V2 1, 2, 5, 7 4
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 1, 2, 5, 7 4
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 1, 2, 5, 7 4
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 1, 2, 5, 7 4
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 1, 2, 5, 7 4
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 1, 2, 5, 7 4
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 1, 2, 5, 7 4
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 1, 2, 5, 7 4
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 1, 2, 5, 7 4
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 1, 2, 5, 7 4
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 1, 2, 5, 7 4
Broadcom (NIC: 1 Gb) PCIe,QP,V2 1, 2, 5, 7 4
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML 1, 2, 5, 7 4
Mellanox (NIC: HDR VPI) HDRV,1P,Q56 3, 6 2
Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 1, 2, 5, 7 4
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2,18F 1, 2, 5, 7 2
FOXCONN (External Adapter) H840 FH,V3,18F 1, 2, 5, 7 2
FOXCONN (External Adapter) H840 LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840 LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 1, 2, 5, 7 2
FOXCONN (External Adapter) HBA355e 3, 6, 1, 2, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 1, 2, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 1, 2, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 1, 2, 5, 7 2
Inventec (BOSS-S1) V4,SATA,FH 1, 2, 5, 7, 8 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 1, 2, 5, 7, 8 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 1, 2, 5, 7, 8 7
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 1, 2, 5, 7, 8 7
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 1, 2, 5, 7, 8 7
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 1, 2, 5, 7, 8 7
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 1, 2, 5, 7, 8 7
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 1, 2, 5, 7, 8 7
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 1, 2, 5, 7, 8 7
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 1, 2, 5, 7, 8 7
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 1, 2, 5, 7, 8 7
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 1, 2, 5, 7, 8 7
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 1, 2, 5, 7, 8 7
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 1, 2, 5, 7, 8 7
Table 10. Configuration 7: R1D + R2A + R3B + R4DRiser configuration R1D + R2A + R3B + R4D.
Card type Slot priority Maximum number of cards
Inventec (Serial) FH,SVR,15G 4 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 5, 4 2
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 5, 4 2
QLogic (NIC: 25 Gb) DPSFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,25G,SFP 5, 4 2
Intel (NIC: 25 Gb) FH,2P,S28,F1 5, 4 2
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH 5, 4 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 5, 4 2
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 5, 4 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 5, 4 2
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 5, 4 2
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 5, 4 2
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 5, 4 2
Emulex (HBA: FC32) FH,2P,V1.1 5, 4 2
Emulex (HBA: FC32) 2P,LPE35002,FH 5, 4 2
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32 LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 5, 4 2
Emulex (HBA: FC32) FH,1P,S28 5, 4 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 5, 4 2
QLogic (HBA: FC32) FH,1P,S28,F1 5, 4 2
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 5, 4 2
QLogic (HBA: FC32) FH,2P,S28,F1 5, 4 2
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 5, 4 2
Emulex (HBA: FC16) FH,1P,SF+,F1 5, 4 2
Emulex (HBA: FC16) 1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16 ) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16 ) 2P,LPE31002 5, 4 2
Emulex (HBA: FC16) FH,2P,SF+,F1 5, 4 2
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 5, 4 2
QLogic (HBA: FC16) FH,1P,S28,F1 5, 4 2
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) FH,DP,V2 5, 4 2
QLogic (HBA: FC16) FH,2P,S28,F1 5, 4 2
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,V2 5, 4 2
QLogic (NIC: 10 Gb) DP,VT,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 5, 4 2
QLogic (NIC: 10 Gb) QP 5, 4 2
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 5, 4 2
Intel (NIC: 10 Gb) SFP+,V2 5, 4 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 5, 4 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 5, 4 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 5, 4 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 5, 4 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 5, 4 2
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 5, 4 2
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 5, 4 2
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 5, 4 2
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 5, 4 2
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 5, 4 2
Broadcom (NIC: 1 Gb) PCIe,QP,V2 5, 4 2
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR VPI) LP,1P,Q56 3, 6 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2,18F 5, 4 2
FOXCONN (External Adapter) H840 FH,V3,18F 5, 4 2
FOXCONN (External Adapter) H840 LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840 LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 5, 4 2
FOXCONN (External Adapter) HBA355e 3, 6, 5, 4 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 5, 4 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 5, 4 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 5, 4 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 5, 4 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 5, 4 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 5, 4 4
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 5, 4 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 5, 4 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 5, 4 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 5, 4 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 5, 4 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 5, 4 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 5, 4 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 5, 4 4
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 5, 4 4
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 5, 4 4
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 5, 4 4
Table 11. Configuration 8-1: R1A + R2A + R4A (FL)Riser configuration R1A + R2A + R4A (FL).
Card type Slot priority Maximum number of cards
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front) H755,MXC Internal slot 1
Inventec (Front PERC)VH745,V3 Internal slot 1
FOXCONN (Front PERC) H345,V2 Internal slot 1
FOXCONN (Front PERC)H355 Internal slot 1
FOXCONN (Front PERCHBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i,V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 3 1
FOXCONN (PERC Adapter) HBA345 V2 3 1
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) DP,QSF 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) SFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) DP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 3, 6 2
Emulex (HBA: FC32) FH,2P,V1.1 3, 6 2
Emulex (HBA: FC32) FH,2P,LPE35002 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 3, 6 2
QLogic (HBA: FC32) FH,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 3, 6 2
Emulex (HBA: FC16) FH,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31002 3, 6 2
Emulex (HBA: FC16) FH,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) 1P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,LP,V2 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,LP,F1 3, 6 2
Broadcom (NIC: 1 Gb) LP,V2 3, 6 2
Mellanox (NIC: HDR100) PCIe,CX6,SP,L,ML 3, 6 2
Mellanox (NIC: HDR VPI) LP,1P,Q56 3, 6 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 LP,V2 3, 6 2
FOXCONN (External Adapter) H840 LP,V3 3, 6 2
FOXCONN (External Adapter) H840 3, 6 2
FOXCONN (External Adapter) HBA355e 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA FH 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA 3, 6 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6 2
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6 2
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6 2
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6 2
Table 12. Configuration 8-2: R1A + R2A + R4A (HL)Riser configuration R1A + R2A + R4A (HL).
Card type Slot priority Maximum number of cards
Inventec (Serial) FH,SVR,15G 8 1
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front) H755,MXC Internal slot 1
Inventec (Front PERC)VH745,V3 Internal slot 1
FOXCONN (Front PERC) H345,V2 Internal slot 1
FOXCONN (Front PERC)H355 Internal slot 1
FOXCONN (Front PERCHBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i,V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 3 1
FOXCONN (PERC Adapter) HBA345 V2 3 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 2, 7 2
Mellanox (NIC: 100G) LP,2P,Q56 3, 6 2
NAPATECH (NIC: 100 Gb) DP,QSFP28 2, 7 2
Mellanox (NIC: 100 Gb) CX5,DP,QSFP 2, 7 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) FH,2P,Q28 2, 7 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) FH,2P,QSF 2, 7 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 2, 7 2
QLogic (NIC: 25 Gb) DP,SFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,SFP 2, 7 2
Intel (NIC: 25 Gb) FH,2P,S28,F1 2, 7 2
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) FH,2P,S28 2, 7 2
Mellanox (NIC: 25 Gb) FH,2P,S28,F1 2, 7 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,FH 2, 7 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 2, 7 2
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 2, 7 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 2, 7 2
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 2, 7 2
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,4P,S28 2, 7 2
Broadcom (NIC: 25 Gb) FH,4P,S28 2, 7 2
Mellanox (NIC: 25 Gb) FH,2P,S28 2, 7 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 2, 7 2
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 2, 7 2
Emulex (HBA: FC32) FH,2P,V1.1 2, 7 2
Emulex (HBA: FC32) 2P,LPE35002,FH 2, 7 2
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32) LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 2, 7 2
Emulex (HBA: FC32) FH,1P,S28 2, 7 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 2, 7 2
QLogic (HBA: FC32) FH,1P,S28,F1 2, 7 2
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 2, 7 2
QLogic (HBA: FC32) FH,2P,S28,F1 2, 7 2
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 2, 7 2
Emulex (HBA: FC16) FH,1P,SF+,F1 2, 7 2
Emulex (HBA: FC16)1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31002 2, 7 2
Emulex (HBA: FC16) FH,2P,SF+,F1 2, 7 2
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 2, 7 2
QLogic (HBA: FC16) FH,1P,S28,F1 2, 7 2
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,FH,V2 2, 7 2
QLogic (HBA: FC16) FH,2P,S28,F1 2, 7 2
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,QLG,V2 2, 7 2
QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 2, 7 2
QLogic (NIC: 10 Gb) QP 2, 7 2
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 2, 7 2
Intel (NIC: 10 Gb) SFP+,V2 2, 7 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 2, 7 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 2, 7 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 2, 7 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 2, 7 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 2, 7 2
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 2, 7 2
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 2, 7 2
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 2, 7 2
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 2, 7 2
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 2, 7 2
Broadcom (NIC: 1 Gb) PCIe,QP,V2 2, 7 2
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML 2, 7 2
Mellanox (NIC: HDR VPI) HDRV,1P,Q56 3, 6 2
Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 2, 7 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2,18F 2, 7 2
FOXCONN (External Adapter) H840 FH,V3,18F 2, 7 2
FOXCONN (External Adapter) H840 LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840 LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 2, 7 2
FOXCONN (External Adapter) HBA355e 3, 6, 2, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 2, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 2, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 2, 7 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 2, 7 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 2, 7 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 2, 7 4
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 2, 7 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 2, 7 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 2, 7 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 2, 7 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 2, 7 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 2, 7 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 2, 7 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 2, 7 4
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 2, 7 4
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 2, 7 4
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 2, 7 4
Table 13. Configuration 9: R1B + R2A + R4BRiser configuration R1B + R2A + R4B.
Card type Slot priority Maximum number of cards
Inventec (Serial) FH,SVR,15G 8 1
FOXCONN (Front PERC ASSY,CRD,CTL,H755,FRONT Internal slot 1
FOXCONN (Front PERC ASSY,CRD,CTL,H755,FRT,MXC Internal slot 1
Inventec (Front PERC ASSY,CRD,CTL,H745,4 Gb,FPERC,V3 Internal slot 1
FOXCONN (Front PERC ASSY,CRD,CTL,H345,FPERC,V2 Internal slot 1
FOXCONN (Front PERC ASSY,CRD,CTL,H355,FPERC Internal slot 1
FOXCONN (Front PERC PWA,CTL,HBA355I,FRONT Internal slot 1
FOXCONN (Front PERC PWA,CTL,HBA355I,FRONT,V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 3 1
FOXCONN (PERC Adapter) HBA345 V2 3 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 1, 2, 7, 8 4
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 1, 2, 7 3
QLogic (NIC: 25 Gb) DPSFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,25G,SFP 1, 2, 7 3
Intel (NIC: 25 Gb) FH,2P,S28,F1 1, 2, 7 3
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH 1, 2, 7 3
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 1, 2, 7 3
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 1, 2, 7 3
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 1, 2, 7 3
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 1, 2, 7 3
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 1, 2, 7 3
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 1, 2, 7 3
Emulex (HBA: FC32) FH,2P,V1.1 1, 2, 7 3
Emulex (HBA: FC32) 2P,LPE35002,FH 1, 2, 7 3
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32 LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 1, 2, 7 3
Emulex (HBA: FC32) FH,1P,S28 1, 2, 7 3
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 1, 2, 7 3
QLogic (HBA: FC32) FH,1P,S28,F1 1, 2, 7 3
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 1, 2, 7 3
QLogic (HBA: FC32) FH,2P,S28,F1 1, 2, 7 3
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 1, 2, 7 3
Emulex (HBA: FC16) FH,1P,SF+,F1 1, 2, 7 3
Emulex (HBA: FC16) 1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16 ) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16 ) 2P,LPE31002 1, 2, 7 3
Emulex (HBA: FC16) FH,2P,SF+,F1 1, 2, 7 3
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 1, 2, 7 3
QLogic (HBA: FC16) FH,1P,S28,F1 1, 2, 7 3
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) FH,DP,V2 1, 2, 7 3
QLogic (HBA: FC16) FH,2P,S28,F1 1, 2, 7 3
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,V2 1, 2, 7 3
QLogic (NIC: 10 Gb) DP,VT,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 1, 2, 7 3
QLogic (NIC: 10 Gb) QP 1, 2, 7 3
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 1, 2, 7 3
Intel (NIC: 10 Gb) SFP+,V2 1, 2, 7 3
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 1, 2, 7 3
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 1, 2, 7 3
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 1, 2, 7 3
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 1, 2, 7 3
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 1, 2, 7 3
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 1, 2, 7 3
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 1, 2, 7 3
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 1, 2, 7 3
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 1, 2, 7 3
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 1, 2, 7 3
Broadcom (NIC: 1 Gb) PCIe,QP,V2 1, 2, 7 3
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR VPI) LP,1P,Q56 3, 6 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2,18F 1, 2, 7 2
FOXCONN (External Adapter) H840 FH,V3,18F 1, 2, 7 2
FOXCONN (External Adapter) H840 LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840 LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 1, 2, 7 2
FOXCONN (External Adapter) HBA355e 3, 6, 1, 2, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 1, 2, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 1, 2, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 1, 2, 7 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 1, 2, 7, 8 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 1, 2, 7, 8 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 1, 2, 7, 8 6
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 1, 2, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 1, 2, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 1, 2, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 1, 2, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 1, 2, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 1, 2, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 1, 2, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 1, 2, 7, 8 6
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 1, 2, 7, 8 6
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 1, 2, 7, 8 6
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 1, 2, 7, 8 6
Table 14. Configuration 10: R2A + R4BRiser configuration 10: R2A + R4B.
Card type Slot priority Maximum number of cards
Inventec (Serial) FH,SVR,15G 8 1
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front PERC) H755,MXC Internal slot 1
Inventec (Front PERC) H745,V3 Internal slot 1
FOXCONN (Front PERC) H345,V2 Internal slot 1
FOXCONN (Front PERC) H355 Internal slot 1
FOXCONN (Front PERC) HBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i,V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 7, 8 2
FOXCONN (PERC Adapter) HBA345 V2 3, 6 2
Mellanox (NIC: 100 Gb) FH,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 7 1
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 7 1
QLogic (NIC: 25 Gb) DPSFP,LP,V2 7 1
Intel (NIC: 25 Gb) DP,25G,SFP 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28,F1 3, 6 2
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 7 1
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 7 1
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH 7 1
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 3, 6 2
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 7 1
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 7 1
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28 7 1
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 7 1
Emulex (HBA: FC64) LP,2P,S28 7 1
Emulex (HBA: FC32) 2P,LPE35002 7 1
Emulex (HBA: FC32) FH,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,FH 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32 LP,2P,V1.1 7 1
Emulex (HBA: FC32) 2P,LPE35002,LP 7 1
Emulex (HBA: FC32) FH,1P,S28 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 7 1
Emulex (HBA: FC32) LP,1P,S28 7 1
QLogic (HBA: FC32) FH,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) LP,1P,S28 7 1
QLogic (HBA: FC32) LP,1P,S28,F1 7 1
QLogic (HBA: FC32) FH,2P,S28 3, 6 2
QLogic (HBA: FC32) FH,2P,S28,F1 3, 6 2
QLogic (HBA: FC32) LP,2P,S28 7 1
QLogic (HBA: FC32) LP,2P,S28,F1 7 1
Emulex (HBA: FC16) 1P,LPE31000 3, 6 2
Emulex (HBA: FC16) FH,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31K0,L 7 1
Emulex (HBA: FC16 ) LP,1P,SF+,F1 7 1
Emulex (HBA: FC16 ) 2P,LPE31002 3, 6 2
Emulex (HBA: FC16) FH,2P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31K2,L 7 1
Emulex (HBA: FC16) LP,2P,SF+,F1 7 1
QLogic (HBA: FC16) SP,2690,FH,V2 3, 6 2
QLogic (HBA: FC16) FH,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,LP,V2 7 1
QLogic (HBA: FC16) LP,1P,S28,F1 7 1
QLogic (HBA: FC16) FH,DP,V2 3, 6 2
QLogic (HBA: FC16) FH,2P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,LP,V2 7 1
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,V2 7 1
QLogic (NIC: 10 Gb) DP,VT,LP,V2 7 1
QLogic (NIC: 10 Gb) SFP,QP 3, 6 2
QLogic (NIC: 10 Gb) QP 3, 6 2
QLogic (NIC: 10 Gb) QP,LP 7 1
Intel (NIC: 10 Gb) LP,V2 7 1
Intel (NIC: 10 Gb) SFP+ 3, 6 2
Intel (NIC: 10 Gb) SFP+,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 7 1
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 7 1
Intel (NIC: 10 Gb) SFP+,DP,FVL 7 1
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 7 1
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 7 1
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 7 1
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 7 1
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 7 1
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 3, 6 2
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 7 1
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 7 1
Intel (NIC: 1 Gb) PCIe,QP,V3 7 1
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 3, 6 2
Broadcom (NIC: 1 Gb) PCIe,QP,V2 3, 6 2
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L Internal slot 1
Mellanox (NIC: HDR VPI) LP,1P,Q56 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840,FH,V2,18F 7 1
FOXCONN (External Adapter) H840,FH,V3,18F 7 1
FOXCONN (External Adapter) H840,LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840,LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 7 2
FOXCONN (External Adapter) HBA355e 3, 6, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 7 1
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 7 1
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 7 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 7, 8 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 7, 8 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 7, 8 4
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 7, 8 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 7, 8 4
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 7, 8 4
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 7, 8 4
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 7, 8 4
Table 15. Configuration 11: R1D + R2A + R3B + R4B Riser configuration 11: R1D + R2A + R3B + R4B
Card type Slot priority Maximum number of cards
Inventec (Serial) FH,SVR,15G 4, 8 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 4, 5, 7, 8 4
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 4, 5, 7 3
QLogic (NIC: 25 Gb) DPSFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,25G,SFP 4, 5, 7 3
Intel (NIC: 25 Gb) FH,2P,S28,F1 4, 5, 7 3
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH 4, 5, 7 3
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 4, 5, 7 3
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 4, 5, 7 3
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 4, 5, 7 3
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 4, 5, 7 3
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 4, 5, 7 3
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 4, 5, 7 3
Emulex (HBA: FC32) FH,2P,V1.1 4, 5, 7 3
Emulex (HBA: FC32) 2P,LPE35002,FH 4, 5, 7 3
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32 LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 4, 5, 7 3
Emulex (HBA: FC32) FH,1P,S28 4, 5, 7 3
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 4, 5, 7 3
QLogic (HBA: FC32) FH,1P,S28,F1 4, 5, 7 3
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 4, 5, 7 3
QLogic (HBA: FC32) FH,2P,S28,F1 4, 5, 7 3
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 4, 5, 7 3
Emulex (HBA: FC16) FH,1P,SF+,F1 4, 5, 7 3
Emulex (HBA: FC16) 1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16 ) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16 ) 2P,LPE31002 4, 5, 7 3
Emulex (HBA: FC16) FH,2P,SF+,F1 4, 5, 7 3
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 4, 5, 7 3
QLogic (HBA: FC16) FH,1P,S28,F1 4, 5, 7 3
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) FH,DP,V2 4, 5, 7 3
QLogic (HBA: FC16) FH,2P,S28,F1 4, 5, 7 3
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,V2 4, 5, 7 3
QLogic (NIC: 10 Gb) DP,VT,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 4, 5, 7 3
QLogic (NIC: 10 Gb) QP 4, 5, 7 3
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 4, 5, 7 3
Intel (NIC: 10 Gb) SFP+,V2 4, 5, 7 3
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 4, 5, 7 3
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 4, 5, 7 3
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 4, 5, 7 3
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 4, 5, 7 3
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 4, 5, 7 3
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 4, 5, 7 3
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 4, 5, 7 3
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 4, 5, 7 3
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 4, 5, 7 3
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 4, 5, 7 3
Broadcom (NIC: 1 Gb) PCIe,QP,V2 4, 5, 7 3
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR VPI) LP,1P,Q56 3, 6 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840,FH,V2,18F 4, 5, 7 2
FOXCONN (External Adapter) H840,FH,V3,18F 4, 5, 7 2
FOXCONN (External Adapter) H840,LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840,LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 4, 5, 7 2
FOXCONN (External Adapter) HBA355e 3, 6, 4, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 4, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 4, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 4, 5, 7 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 4, 5, 7, 8 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 4, 5, 7, 8 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 4, 5, 7, 8 6
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 4, 5, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 4, 5, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 4, 5, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 4, 5, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 4, 5, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 4, 5, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 4, 5, 7, 8 6
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 4, 5, 7, 8 6
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 4, 5, 7, 8 6
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 4, 5, 7, 8 6
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 4, 5, 7, 8 6
Table 16. Config12-1: R1D+R2A+R3A+R4A(FL)Config12-1: R1D+R2A+R3A+R4A(FL)
Card type Slot priority Maximum number of cards
Xilinx (Accelerators - FPGAs) 225 W,PSV,FH 5, 7 2
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32) LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31K0,EM,L 3, 6 2
Emulex (HBA: FC16) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) LP,10G,2P,BT 3, 6 2
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) LP,V3 3, 6 2
Intel (NIC: 1 Gb) LP,F1 3, 6 2
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR VPI) LP,1P,Q56 3, 6 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 LP,V2 3, 6 2
FOXCONN (External Adapter) H840 LP,V3 3, 6 2
FOXCONN (External Adapter) H840 3, 6 2
FOXCONN (External Adapter) HBA355e 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA FH 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA 3, 6 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6 2
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6 2
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6 2
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6 2
Table 17. Configuration12-2:R1D+R2A+R3A+R4A (HL)Configuration12-2:R1D+R2A+R3A+R4A (HL)
Card type Slot priority Maximum number of cards
Inventec (Serial) SVR,15G 4, 8 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 5, 7 2
Mellanox (NIC: 100G) LP,2P,Q56 3, 6 2
NAPATECH (NIC: 100 Gb) DP,QSFP28 5, 7 2
Mellanox (NIC: 100 Gb) CX5,DP,QSFP 5, 7 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) FH,2P,Q28 5, 7 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) FH,2P,QSF 5, 7 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 5, 7 2
QLogic (NIC: 25 Gb) DP,SFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,SFP 5, 7 2
Intel (NIC: 25 Gb) FH,2P,S28,F1 5, 7 2
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) FH,2P,S28 5, 7 2
Mellanox (NIC: 25 Gb) FH,2P,S28,F1 5, 7 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,FH 5, 7 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 5, 7 2
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 5, 7 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 5, 7 2
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 5, 7 2
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,4P,S28 5, 7 2
Broadcom (NIC: 25 Gb) FH,4P,S28 5, 7 2
Mellanox (NIC: 25 Gb) FH,2P,S28 5, 7 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 5, 7 2
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 5, 7 2
Emulex (HBA: FC32) FH,2P,V1.1 5, 7 2
Emulex (HBA: FC32) 2P,LPE35002,FH 5, 7 2
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32) LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 5, 7 2
Emulex (HBA: FC32) FH,1P,S28 5, 7 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 5, 7 2
QLogic (HBA: FC32) FH,1P,S28,F1 5, 7 2
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 5, 7 2
QLogic (HBA: FC32) FH,2P,S28,F1 5, 7 2
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 5, 7 2
Emulex (HBA: FC16) FH,1P,SF+,F1 5, 7 2
Emulex (HBA: FC16)1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31002 5, 7 2
Emulex (HBA: FC16) FH,2P,SF+,F1 5, 7 2
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 5, 7 2
QLogic (HBA: FC16) FH,1P,S28,F1 5, 7 2
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,FH,V2 5, 7 2
QLogic (HBA: FC16) FH,2P,S28,F1 5, 7 2
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,QLG,V2 5, 7 2
QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 5, 7 2
QLogic (NIC: 10 Gb) QP 5, 7 2
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 5, 7 2
Intel (NIC: 10 Gb) SFP+,V2 5, 7 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 5, 7 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 5, 7 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 5, 7 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 5, 7 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 5, 7 2
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 5, 7 2
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 5, 7 2
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 5, 7 2
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 5, 7 2
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 5, 7 2
Broadcom (NIC: 1 Gb) PCIe,QP,V2 5, 7 2
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML 5, 7 2
Mellanox (NIC: HDR VPI) HDRV,1P,Q56 3, 6 2
Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 5, 7 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840,FH,V2,18F 5, 7 2
FOXCONN (External Adapter) H840,FH,V3,18F 5, 7 2
FOXCONN (External Adapter) H840,LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840,LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 5, 7 2
FOXCONN (External Adapter) HBA355e 3, 6, 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 5, 7 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 5, 7 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 5, 7 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 5, 7 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 5, 7 4
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 5, 7 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 5, 7 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 5, 7 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 5, 7 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 5, 7 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 5, 7 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 5, 7 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 5, 7 4
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 5, 7 4
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 5, 7 4
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 5, 7 4
Table 18. Configuration13-1: R1A+R2A+R3A (FL)Configuration13-1: R1A+R2A+R3A (FL)
Card type Slot priority Maximum number of cards
FOXCONN (Front PERC) H755N Internal slot 2
FOXCONN (Front PERC) H755N MXC Internal slot 2
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front PERC) H755 MXC Internal slot 1
Inventec (Front PERC) H745 V3 Internal slot 1
Inventec (Front PERC) H745 V2 Internal slot 1
Inventec (Front PERC) H745 Internal slot 1
FOXCONN (Front PERC) H345 V2 Internal slot 1
FOXCONN (Front PERC) H345 Internal slot 1
FOXCONN (Front PERC) H355 Internal slot 1
FOXCONN (Front PERC) HBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i V2 Internal slot 1
FOXCONN (Front PERC) HBA345 Internal slot 1
FOXCONN (Front PERC) HBA345 V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 3 1
FOXCONN (PERC Adapter) HBA345 V2 3 1
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) DP,QSF 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) SFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) DP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 3, 6 2
Emulex (HBA: FC32) FH,2P,V1.1 3, 6 2
Emulex (HBA: FC32) FH,2P,LPE35002 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 3, 6 2
QLogic (HBA: FC32) FH,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 3, 6 2
Emulex (HBA: FC16) FH,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31002 3, 6 2
Emulex (HBA: FC16) FH,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) 1P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,LP,V2 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,LP,F1 3, 6 2
Broadcom (NIC: 1 Gb) LP,V2 3, 6 2
Mellanox (NIC: HDR100) PCIe,CX6,SP,L,ML 3, 6 2
Mellanox (NIC: HDR VPI) LP,1P,Q56 3, 6 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 LP,V2 3, 6 2
FOXCONN (External Adapter) H840 LP,V3 3, 6 2
FOXCONN (External Adapter) H840 3, 6 2
FOXCONN (External Adapter) HBA355e 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA FH 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA V2,FH 3, 6 2
FOXCONN (External Adapter) 12 Gb SAS-HBA 3, 6 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6 2
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6 2
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6 2
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6 2
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6 2
Table 19. Configuration13-2: R1A+R2A+R3A (HL)Configuration13-2: R1A+R2A+R3A (HL)
Card type Slot priority Maximum number of cards
Inventec (Serial ASSY,CRD,SER,FH,SVR,15G 4 1
FOXCONN (Front PERC) H755N Internal slot 2
FOXCONN (Front PERC) H755N MXC Internal slot 2
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front PERC) H755 MXC Internal slot 1
Inventec (Front PERC) H745 V3 Internal slot 1
Inventec (Front PERC) H745 V2 Internal slot 1
Inventec (Front PERC) H745 Internal slot 1
FOXCONN (Front PERC) H345 V2 Internal slot 1
FOXCONN (Front PERC) H345 Internal slot 1
FOXCONN (Front PERC) H355 Internal slot 1
FOXCONN (Front PERC) HBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i V2 Internal slot 1
FOXCONN (Front PERC) HBA345 Internal slot 1
FOXCONN (Front PERC) HBA345 V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 3 1
FOXCONN (PERC Adapter) HBA345 V2 3 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 2, 5 2
Mellanox (NIC: 100G) LP,2P,Q56 3, 6 2
NAPATECH (NIC: 100 Gb) DP,QSFP28 2, 5 2
Mellanox (NIC: 100 Gb) CX5,DP,QSFP 2, 5 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) FH,2P,Q28 2, 5 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) FH,2P,QSF 2, 5 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 2, 5 2
QLogic (NIC: 25 Gb) DP,SFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,SFP 2, 5 2
Intel (NIC: 25 Gb) FH,2P,S28,F1 2, 5 2
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) FH,2P,S28 2, 5 2
Mellanox (NIC: 25 Gb) FH,2P,S28,F1 2, 5 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) DP,57414,FH 2, 5 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 2, 5 2
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 2, 5 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 2, 5 2
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 2, 5 2
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,4P,S28 2, 5 2
Broadcom (NIC: 25 Gb) FH,4P,S28 2, 5 2
Mellanox (NIC: 25 Gb) FH,2P,S28 2, 5 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 2, 5 2
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 2, 5 2
Emulex (HBA: FC32) FH,2P,V1.1 2, 5 2
Emulex (HBA: FC32) 2P,LPE35002,FH 2, 5 2
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32) LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 2, 5 2
Emulex (HBA: FC32) FH,1P,S28 2, 5 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 2, 5 2
QLogic (HBA: FC32) FH,1P,S28,F1 2, 5 2
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 2, 5 2
QLogic (HBA: FC32) FH,2P,S28,F1 2, 5 2
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 2, 5 2
Emulex (HBA: FC16) FH,1P,SF+,F1 2, 5 2
Emulex (HBA: FC16)1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16) 2P,LPE31002 2, 5 2
Emulex (HBA: FC16) FH,2P,SF+,F1 2, 5 2
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 2, 5 2
QLogic (HBA: FC16) FH,1P,S28,F1 2, 5 2
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) DP,2692,FH,V2 2, 5 2
QLogic (HBA: FC16) FH,2P,S28,F1 2, 5 2
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,QLG,V2 2, 5 2
QLogic (NIC: 10 Gb) DP,BT,QLG,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 2, 5 2
QLogic (NIC: 10 Gb) QP 2, 5 2
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 2, 5 2
Intel (NIC: 10 Gb) SFP+,V2 2, 5 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 2, 5 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 2, 5 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 2, 5 2
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 2, 5 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 2, 5 2
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 2, 5 2
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 2, 5 2
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 2, 5 2
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 2, 5 2
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 2, 5 2
Broadcom (NIC: 1 Gb) PCIe,QP,V2 2, 5 2
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,F,ML 2, 5 2
Mellanox (NIC: HDR VPI) HDRV,1P,Q56 3, 6 2
Mellanox (NIC: HDR VPI) FH,HDRV,1P,Q56 2, 5 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2,18F 2, 5 2
FOXCONN (External Adapter) H840 FH,V3,18F 2, 5 2
FOXCONN (External Adapter) H840 LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840 LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 2, 5 2
FOXCONN (External Adapter) HBA355e 3, 6, 2, 5 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 2, 5 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 2, 5 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 2, 5 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 2, 5 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 2, 5 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 2, 5 4
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 2, 5 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 2, 5 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 2, 5 4
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 2, 5 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 2, 5 4
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 2, 5 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 2, 5 4
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 2, 5 4
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 2, 5 4
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 2, 5 4
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 2, 5 4
Table 20. Configuration 14: R1B+R2A+R3BConfiguration 14: R1B+R2A+R3B
Card type Slot priority Maximum number of cards
Inventec (Serial ASSY,CRD,SER,FH,SVR,15G 4 1
FOXCONN (Front PERC) H755N Internal slot 2
FOXCONN (Front PERC) H755N MXC Internal slot 2
FOXCONN (Front PERC) H755 Internal slot 1
FOXCONN (Front PERC) H755 MXC Internal slot 1
Inventec (Front PERC) H745 V3 Internal slot 1
Inventec (Front PERC) H745 V2 Internal slot 1
Inventec (Front PERC) H745 Internal slot 1
FOXCONN (Front PERC) H345 V2 Internal slot 1
FOXCONN (Front PERC) H345 Internal slot 1
FOXCONN (Front PERC) H355 Internal slot 1
FOXCONN (Front PERC) HBA355i Internal slot 1
FOXCONN (Front PERC) HBA355i V2 Internal slot 1
FOXCONN (Front PERC) HBA345 Internal slot 1
FOXCONN (Front PERC) HBA345 V2 Internal slot 1
FOXCONN (PERC Adapter) H755 3 1
FOXCONN (PERC Adapter) H755 MXC 3 1
Inventec (PERC Adapter) H745 V2 3 1
Inventec (PERC Adapter) H745 3 1
FOXCONN (PERC Adapter) H355 3 1
FOXCONN (PERC Adapter) H345 V2 3 1
FOXCONN (PERC Adapter) H345 3 1
FOXCONN (PERC Adapter) HBA355i 3 1
FOXCONN (PERC Adapter) HBA355i V2 3 1
FOXCONN (PERC Adapter) HBA345 3 1
FOXCONN (PERC Adapter) HBA345 V2 3 1
Mellanox (NIC: 100 Gb) FH,2P,Q56 4, 5, 1, 2 4
Mellanox (NIC: 100 Gb) LP,2P,Q56 3, 6 2
Mellanox (NIC: 100 Gb) CX5,DP,QSF,L 3, 6 2
Intel (NIC: 100 Gb) LP,2P,Q28 3, 6 2
Broadcom (NIC: 100 Gb) LP,2P,QSF 3, 6 2
QLogic (NIC: 25 Gb) DP,SFP,V2 4, 5, 1, 2 4
QLogic (NIC: 25 Gb) DPSFP,LP,V2 3, 6 2
Intel (NIC: 25 Gb) DP,25G,SFP 4, 5, 1, 2 4
Intel (NIC: 25 Gb) FH,2P,S28,F1 4, 5, 1, 2 4
Intel (NIC: 25 Gb) DP,SFP,LP 3, 6 2
Intel (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28,F1 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH 4, 5, 1, 2 4
Broadcom (NIC: 25 Gb) PCIe,DP,57414,FH2 4, 5, 1, 2 4
Broadcom (NIC: 25 Gb) FH,2P,SFP,F1 4, 5, 1, 2 4
Broadcom (NIC: 25 Gb) PCIe,DP,57414,LP 3, 6 2
Broadcom (NIC: 25 Gb) PCIe,DPG,57414,LP2 3, 6 2
Broadcom (NIC: 25 Gb) LP,2P,SFP,F1 3, 6 2
QLogic (NIC: 25 Gb) FH,2P,S28 4, 5, 1, 2 4
QLogic (NIC: 25 Gb) LP,2P,S28 3, 6 2
Intel (NIC: 25 Gb) FH,2P,S28 4, 5, 1, 2 4
Intel (NIC: 25 Gb) LP,2P,S28 3, 6 2
Mellanox (NIC: 25 Gb) LP,2P,S28 3, 6 2
Emulex (HBA: FC64) FH,2P,S28 4, 5, 1, 2 4
Emulex (HBA: FC64) LP,2P,S28 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002 4, 5, 1, 2 4
Emulex (HBA: FC32) FH,2P,V1.1 4, 5, 1, 2 4
Emulex (HBA: FC32) 2P,LPE35002,FH 4, 5, 1, 2 4
Emulex (HBA: FC32) 2P,LPE35002,L 3, 6 2
Emulex (HBA: FC32 LP,2P,V1.1 3, 6 2
Emulex (HBA: FC32) 2P,LPE35002,LP 3, 6 2
Emulex (HBA: FC32) FH,1P,S28 4, 5, 1, 2 4
Emulex (HBA: FC32) FH,1P,S28 4, 5, 1, 2 4
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
Emulex (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) FH,1P,S28 4, 5, 1, 2 4
QLogic (HBA: FC32) FH,1P,S28,F1 4, 5, 1, 2 4
QLogic (HBA: FC32) LP,1P,S28 3, 6 2
QLogic (HBA: FC32) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC32) FH,2P,S28 4, 5, 1, 2 4
QLogic (HBA: FC32) FH,2P,S28,F1 4, 5, 1, 2 4
QLogic (HBA: FC32) LP,2P,S28 3, 6 2
QLogic (HBA: FC32) LP,2P,S28,F1 3, 6 2
Emulex (HBA: FC16) 1P,LPE31000 4, 5, 1, 2 4
Emulex (HBA: FC16) FH,1P,SF+,F1 4, 5, 1, 2 4
Emulex (HBA: FC16) 1P,LPE31K0,L 3, 6 2
Emulex (HBA: FC16 ) LP,1P,SF+,F1 3, 6 2
Emulex (HBA: FC16 ) 2P,LPE31002 4, 5, 1, 2 4
Emulex (HBA: FC16) FH,2P,SF+,F1 4, 5, 1, 2 4
Emulex (HBA: FC16) 2P,LPE31K2,L 3, 6 2
Emulex (HBA: FC16) LP,2P,SF+,F1 3, 6 2
QLogic (HBA: FC16) SP,2690,FH,V2 4, 5, 1, 2 4
QLogic (HBA: FC16) FH,1P,S28,F1 4, 5, 1, 2 4
QLogic (HBA: FC16) SP,2690,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,1P,S28,F1 3, 6 2
QLogic (HBA: FC16) FH,DP,V2 4, 5, 1, 2 4
QLogic (HBA: FC16) FH,2P,S28,F1 4, 5, 1, 2 4
QLogic (HBA: FC16) DP,2692,LP,V2 3, 6 2
QLogic (HBA: FC16) LP,2P,S28,F1 3, 6 2
QLogic (NIC: 10 Gb) DP,BT,V2 4, 5, 1, 2 4
QLogic (NIC: 10 Gb) DP,VT,LP,V2 3, 6 2
QLogic (NIC: 10 Gb) SFP,QP 4, 5, 1, 2 4
QLogic (NIC: 10 Gb) QP 4, 5, 1, 2 4
QLogic (NIC: 10 Gb) QP,LP 3, 6 2
Intel (NIC: 10 Gb) LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+ 4, 5, 1, 2 4
Intel (NIC: 10 Gb) SFP+,V2 4, 5, 1, 2 4
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL,LP,V2 3, 6 2
Intel (NIC: 10 Gb) SFP+,DP,FVL 4, 5, 1, 2 4
Intel (NIC: 10 Gb) SFP+,DP,FVL,V2 4, 5, 1, 2 4
Broadcom (NIC: 10 Gb) PCIe,DP,57416,FH 4, 5, 1, 2 4
Broadcom (NIC: 10 Gb) PCIe,DP,57416,LP 3, 6 2
Broadcom (NIC: 10 Gb) PCIe,DP,57412,FH 4, 5, 1, 2 4
Broadcom (NIC: 10 Gb) PCIe,DP,57412,LP 3, 6 2
QLogic (NIC: 10 Gb) FH,2P,BT 4, 5, 1, 2 4
QLogic (NIC: 10 Gb) LP,2P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,4P,BT 4, 5, 1, 2 4
Intel (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 10 Gb) FH,2P,BT 4, 5, 1, 2 4
Intel (NIC: 10 Gb) LP,2P,BT 3, 6 2
Broadcom (NIC: 10 Gb) FH,4P,BT 4, 5, 1, 2 4
Broadcom (NIC: 10 Gb) LP,4P,BT 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,V3 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,LP,F1 3, 6 2
Intel (NIC: 1 Gb) PCIe,QP,V3 4, 5, 1, 2 4
Intel (NIC: 1 Gb) PCIe,QP,Intel,F1 4, 5, 1, 2 4
Broadcom (NIC: 1 Gb) PCIe,QP,V2 4, 5, 1, 2 4
Broadcom (NIC: 1 Gb) PCIe,QP,LP,V2 3, 6 2
Mellanox (NIC: HDR100 VPI) PCIe,CX6,SP,L 3, 6 2
Mellanox (NIC: HDR VPI) LP,1P,Q56 3, 6 2
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
FOXCONN (External Adapter) H840 FH,V2,18F 4, 5, 1, 2 2
FOXCONN (External Adapter) H840 FH,V3,18F 4, 5, 1, 2 2
FOXCONN (External Adapter) H840 LP,V2,18 3, 6 2
FOXCONN (External Adapter) H840 LP,V3,18 3, 6 2
FOXCONN (External Adapter) H840 3, 6, 4, 5, 1, 2 2
FOXCONN (External Adapter) HBA355e 3, 6, 4, 5, 1, 2 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA FH 4, 5, 1, 2 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,FH 4, 5, 1, 2 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA V2,LPF 3, 6 2
FOXCONN (External Adapter) 12 Gb-SAS-HBA 3, 6, 4, 5, 1, 2 2
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1
Inventec (BOSS-S1) V4,SATA,FH 4, 5, 1, 2 1
Inventec (BOSS-S1) V4,SATA,LP 3, 6 1
Inventec (BOSS-S1) V5,SATA,FH 4, 5, 1, 2 1
Inventec (BOSS-S1) V5,SATA,LP 3, 6 1
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1725B 3, 6, 4, 5, 1, 2 6
SAMSUNG (PCIe SSD)NVMe,3.2 Tb,PM1725B 3, 6, 4, 5, 1, 2 6
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1725B 3, 6, 4, 5, 1, 2 6
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735 3, 6, 4, 5, 1, 2 6
SAMSUNG (PCIe SSD) NVMe,1.6 Tb,PM1735,O 3, 6, 4, 5, 1, 2 6
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735 3, 6, 4, 5, 1, 2 6
SAMSUNG (PCIe SSD) NVMe,3.2 Tb,PM1735,O 3, 6, 4, 5, 1, 2 6
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735 3, 6, 4, 5, 1, 2 6
SAMSUNG (PCIe SSD) NVMe,6.4 Tb,PM1735,O 3, 6, 4, 5, 1, 2 6
Intel (PCIe SSD) NVMe,750 Gb,P4800X 3, 6, 4, 5, 1, 2 6
Intel (PCIe SSD) NVMe,375 Gb,P4800X 3, 6, 4, 5, 1, 2 6
Intel (PCIe SSD) PCIe,375 Gb,P4800X 3, 6, 4, 5, 1, 2 6
Table 21. Configuration 15: R1D + R4DConfiguration 15: R1D + R4D.
Card type Slot priority Maximum number of cards
Broadcom (OCP: 25 Gb) 2P,V2 Internal slot 1
Broadcom (OCP: 25 Gb) 4P,S28 Internal slot 1
Broadcom (OCP: 25 Gb)4P,V2 Internal slot 1
QLogic (OCP: 25 Gb) 2P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
SolarFlare (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 25 Gb) 4P,S28 Internal slot 1
Mellanox (OCP: 25 Gb) 2P,S28 Internal slot 1
Intel (OCP: 10 Gb) 2P,SF+ Internal slot 1
Broadcom (OCP: 10 Gb) 2P,BT Internal slot 1
Broadcom (OCP: 10 Gb) 2P,V2 Internal slot 1
QLogic (OCP: 10 Gb) 2P,BT Internal slot 1
QLogic (OCP: 10 Gb) 2P,SF+ Internal slot 1
Intel (OCP: 10 Gb) 2P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,BT Internal slot 1
Intel (OCP: 10 Gb) 4P,SF+ Internal slot 1
QLogic (OCP: 10 Gb) 4P,BT Internal slot 1
QLogic (OCP: 10 Gb) 4P,SF+ Internal slot 1
Broadcom (OCP: 1 Gb) 4P,BT Internal slot 1
Intel (OCP: 1 Gb) 4P,BT Internal slot 1
Inventec (BOSS-S2) 15G Internal slot 1
Inventec (BOSS-S2) V2,15G Internal slot 1

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.