Dell EMC PowerEdge R840 Installation and Service Manual
Removing IDSDM or vFlash module
Prerequisites
- Follow the safety guidelines listed in Safety instructions.
- Follow the procedure listed in Before working inside your system.
- Remove the air shroud.
- Remove the expansion card riser 1.
Steps
- Locate the IDSDM or vFlash connector on riser 1.
- Holding the pull tab, lift the IDSDM or vFlash module out of the system.
Figure 1. Removing IDSDM or vFlash module
NOTE There are two dip switches on the IDSDM or vFlash module for write-protection.NOTE If you are replacing the IDSDM or vFlash module, remove the microSD cards.
Next steps