Dell PowerEdge R940 Installation and Service Manual
Drive indicator codes
Each drive carrier has an activity LED indicator and a status LED indicator. The indicators provide information about the current status of the drive. The activity LED indicator indicates whether the drive is currently in use or not. The status LED indicator indicates the power condition of the drive.

- Drive activity LED indicator
- Drive status LED indicator
- Drive capacity label
NOTE:If the
drive is in the Advanced Host Controller Interface (AHCI) mode, the
status LED indicator does not turn on.
| Drive status indicator code | Condition |
|---|---|
| Flashes green twice per second | Identifying drive or preparing for removal. |
| Off | Drive ready for
removal. NOTE:The drive
status indicator remains off until all drives are initialized after
the system is turned on. Drives are
not ready for removal during this time. |
| Flashes green, amber, and then turns off | Predicted drive failure. |
| Flashes amber four times per second | Drive failed. |
| Flashes green slowly | Drive rebuilding. |
| Solid green | Drive online. |
| Flashes green for three seconds, amber for three seconds, and then turns off after six seconds | Rebuild stopped. |