Dell PowerEdge R940 Installation and Service Manual
Minimum configuration to POST
The components mentioned below are the minimum configuration to POST:
- Two processor configurations:
- Two Processors one in each socket, processor 1 and processor 2
NOTE: For using Intel 61xx and 81xx series processors, you will need 2 UPI cables. For more information, see the Dell EMC PowerEdge R940 Installation and Service manual.
- Two memory dimms one for processor 1 on channel A1 and second for processor 2 on channel B1
- One power supply unit
- Right control panel and cable (for power button functionality)
- System board
- Two Processors one in each socket, processor 1 and processor 2
- Four processor configurations:
- Four processors in socket processor 1, processor 2, processor 3, and processor 4
- One memory module (DIMM) on each channel A1, B1, C1, D1 for processor 1, processor 2, processor 3, and processor 4
- PEM
- 4 UPI cables and a clock cable
- Two PEM power boards
- One power supply unit
- Right control panel and cable (for power button functionality)
- System board