Dell EMC PowerEdge RAID Controller CLI Reference Guide

PDF

Virtual drive migration commands

NOTE: The virtual drive migration commands are not supported in Embedded MegaRAID.

The PERC Command Line Tool supports the following commands for virtual drive migration (reconstruction):

perccli /cx/vx show migrate
perccli /cx/vx start migrate type=raidx [option=add|remove drives=[e:]s|[e:]s-x|[e:]s-x,y][Force]  

The detailed description for each command follows.

perccli /cx/vx show migrate

This command shows the progress of the virtual drive migrate operation in percentage.

Input example:

perccli /c0/v0 show migrate

perccli /cx/vx start migrate type=raidx [option=add|remove drives=[e:] s| [e:]s-x| [e:]s-x,y] [Force]

This command starts the reconstruction on a virtual drive to the specified RAID level by adding or removing disks from the existing virtual drive. You can use the following options with the start migrate command:

Table 1. Virtual drive migration command optionsThis table lists and describes the virtual drive migration command options.
Options Value range Description
type=raidx RAID [0|1|5|6|10]: The RAID level to which the virtual drive must be migrated.
[option=add|remove drives=[e:]s|[e:]s-x|[e:]s-x,y] [Force]

add: Adds the specified PD to the migrated raid level

remove: Removes the specified PD from the migrated raid level.

drives: Specifies the list of PD's which needs to be added or removed.

force: If specified, then migration will start even if any drive in the DG is secured by FDE.

Virtual drive migration can be done between the following RAID levels:

Table 2. Virtual drive migration tableThis table lists and describes the virtual drive migration.
Initial RAID level Migrated RAID level
RAID 0 RAID 0
RAID 0 RAID 1
RAID 0 RAID 5
RAID 0 RAID 6
RAID 1 RAID 0
RAID 1 RAID 5
RAID 1 RAID 6
RAID 5 RAID 0
RAID 5 RAID 5
RAID 5 RAID 6
RAID 6 RAID 0
RAID 6 RAID 5
RAID 6 RAID 6
RAID 10 RAID 10

Input example:

perccli /c0/v3 start migrate type=r5 option=add drives=134:1-3