Skip to main content

Dell PowerEdge RAID Controller 10 User’s Guide PERC H345, H740P, H745, and H840 Series Controllers

Smart error detected on a physical disk in a non-redundant virtual disk

Issue:
A SMART error is detected on a physical disk in a non-redundant virtual disk.
Corrective Action:
Perform the following steps:
  1. Back up your data.
  2. Use Replace Member or set up a global hot spare to replace the disk automatically.
    NOTE:For more information about the Replace Member feature, see the topic Configuring hot spare.
  3. Replace the affected physical disk with a new physical disk of equal or higher capacity.
  4. Restore from the backup.