Relative humidity specifications

Table 1. Relative humidity specificationsThe following table shows the humidity specifications:
Relative humidity Specifications
Storage 5% to 95% RH with 27°C (80.6°F) maximum dew point. Atmosphere must be noncondensing always.
Operating
  • < 35°C (95°F): 8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F) maximum dew point.
  • 35°C–40°C (95°F–104°F): 8% RH with -12°C minimum dew point to 85% RH with 24°C (75.2°F) maximum dew point.
  • 40°C- 45°C(104°F–113°F): 8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F) maximum dew point