For
systems that support redundant PSU, ensure that all the PSUs are of the same type and have the same maximum output power.
NOTE:The maximum output
power (shown in watts) is listed on the PSU label.
Steps
Slide the PSU into the PSU bay until the release latch snaps into place.
Figure 1. Installing a power
supply unit
Next steps
Connect the power cable to the PSU, and
plug the cable into a power outlet.
CAUTION:When connecting the power cable to the PSU, secure the cable to the
PSU with the strap.
NOTE:When installing hot swapping, or hot adding a new PSU, wait for 15 seconds for the
system to recognize the PSU and determine its
status. The PSU redundancy may not occur until discovery is complete. The PSU status
indicator turns green to indicate that the PSU is functioning properly.