Dell PowerEdge XE9780 Installation and Service Manual
Thermal restriction matrix
| Configuration | E3.S x16 | |||||
|---|---|---|---|---|---|---|
| Component | Processor | cTDP | Cores | Part number | B300 + 4 x PCIe card + 8 x OSFP | B200 +12 x PCIe card |
| CPU | Intel GNR-SP 6787P | 350 W | 86 | 7FRX4 | 2U-Ext HSK/STD Fan | 2U-Ext HSK/STD Fan |
| Intel GNR-SP 6767P | 350 W | 64 | KJWD6 | 2U-Ext HSK/STD Fan | 2U-Ext HSK/STD Fan | |
| Intel GNR-SP 6747P | 330 W | 48 | 92C7P | 2U-Ext HSK/STD Fan | 2U-Ext HSK/STD Fan | |
| Memory | 64GB RDIMM 6400 MT/s | 2U-Ext HSK/STD Fan | 2U-Ext HSK/STD Fan | |||
| 96GB RDIMM 6400 MT/s | 2U-Ext HSK/STD Fan | 2U-Ext HSK/STD Fan | ||||
| 128GB RDIMM 6400 MT/s | 2U-Ext HSK/STD Fan | 2U-Ext HSK/STD Fan | ||||
| DPU | B3220 | STD fan | - | |||
| GPU | NVIDIA B300 1100W 8-way | STD Fan | - | |||
| NVIDIA B200 1000W 8-way | - | STD Fan | ||||
Other Thermal Restrictions
Configurations that support ASHRAE A3 and A4 are not available.
A PCIe blank (DPN: GYP32) is required if no PCIe card is installed in any slot.
A low-profile block is required when installing a low-profile card.
DIMM blanks are required if fewer than 16 DIMMs are installed.
M.2, OCP, and HDD blanks are required if the corresponding components are not installed.
GPU fans are hot-swappable and must be reinstalled within 30 seconds.