    "@odata.type": "#MetricReportDefinition.v1_4_2.MetricReportDefinition",
    "@odata.context": "/Redfish/v1/$metadata#MetricReportDefinition.MetricReportDefinition",
    "@odata.id": "/redfish/v1/TelemetryService/MetricReportDefinitions/CPUSensor",
    "Id": "CPUSensor",
    "Name": "CPU Sensor Metric Report",
    "Description": "CPU Sensor",
    "AppendLimit": 2400,
    "MetricReportDefinitionEnabled": true,
    "MetricReportDefinitionType": "Periodic",
    "MetricReportHeartbeatInterval": "PT0H0M0S",
    "SuppressRepeatedMetricValue": false,
    "ReportTimespan": "PT0H0M0S",
    "ReportUpdates": "Overwrite",
    "Wildcards": [],
    "MetricReportDefinitionType@redfish.AllowableValues": [
        "Periodic",
        "OnChange",
        "OnRequest"
    ],
    "ReportUpdates@redfish.AllowableValues": [
        "AppendStopsWhenFull",
        "AppendWrapsWhenFull",
        "NewReport",
        "Overwrite"
    ],
    "ReportActions": [
        "RedfishEvent",
        "LogToMetricReportsCollection"
    ],
    "ReportActions@Redfish.AllowableValues": [
        "LogToMetricReportsCollection",
        "RedfishEvent"
    ],
    "Status": {
        "State": "Enabled"
    },
    "Schedule": {
        "RecurrenceInterval": "PT0H1M0S"
    },
    "MetricReport": {
        "@odata.id": "/redfish/v1/TelemetryService/MetricReports/CPUSensor"
    },
    "Metrics": [
        {
            "MetricId": "TemperatureReading",
            "MetricProperties": [],
            "CollectionFunction": null,
            "CollectionDuration": null,
            "CollectionTimeScope": "Point",
            "Oem": {
                "Dell": {
                    "@odata.type": "#DellMetric.v1_1_0.DellMetric",
                    "CustomLabel": null,
                    "FQDD": "CPU.Socket.%",
                    "Source": null
                }
            }
        }
    ],
    "Links": {
        "Triggers": [
            {
                "@odata.id": "/redfish/v1/TelemetryService/Triggers/CPUCriticalTrigger"
            },
            {
                "@odata.id": "/redfish/v1/TelemetryService/Triggers/CPUWarnTrigger"
            },
            {
                "@odata.id": "/redfish/v1/TelemetryService/Triggers/TMPCpuCriticalTrigger"
            },
            {
                "@odata.id": "/redfish/v1/TelemetryService/Triggers/TMPCpuWarnTrigger"
            }
        ]
    },
    "Oem": {
        "Dell": {
            "@odata.type": "#DellMetricReportDefinition.v1_1_0.DellMetricReportDefinition",
            "Digest": "0f66e7f33aabe9707728c0b9297d170697df27105f7a672373c131ea8baf9481",
            "iDRACFirmwareVersion": "1.20.25.00"
        }
    }
}