Dell iDRAC Telemetry Reference Guide
Sample Triggers Examples
The provided text describes two types of triggers in Redfish telemetry service: Discrete Trigger and Numeric Trigger, each with its own set of properties and conditions, such as metric type, trigger actions, and threshold values.
Discrete Trigger
{
"@odata.type": "#Triggers.v1_1_1.Triggers",
"@odata.id": "/Redfish/v1/TelemetryService/Triggers/CustomDiscreteTrigger",
"Id": "CustomDiscreteTrigger",
"Name": "Custom Discrete Trigger",
"Description": "Custom Discrete Trigger",
"MetricType": "Discrete",
"TriggerActions": [
" RedfishMetricReport "
],
"DiscreteTriggerCondition": "Specified",
"DiscreteTriggers": [
{
"Value": "Non-operational",
"DwellTime": "PT0.001S",
"Severity": "Warning"
}
],
"MetricIds": [
"OSDriverState"
],
"Links": {
"MetricReportDefinitions":
[
{
"@odata.id": "/Redfish/v1/TelemetryService/MetricReportDefinitions/NICStatistics"
} ]}}
Numeric Trigger
{
"@odata.type": "#Triggers.v1_1_1.Triggers",
"@odata.id": "/Redfish/v1/TelemetryService/Triggers/CustomNumericTrigger",
"Id": "CustomNumericTrigger",
"Name": "Custom Numeric Trigger",
"Description": "Custom Numeric Trigger",
"MetricType": "Numeric",
"TriggerActions": [
"RedfishMetricReport"
],
"NumericThresholds": {
"UpperCritical": {
"Reading": 70,
"Activation": "Increasing",
"DwellTime": "PT0.001S"
},
"UpperWarning": {
"Reading": 65,
"Activation": "Increasing",
"DwellTime": "PT0.004S"
}
},
"MetricIds": [
"TotalCPUPower"
],
"Links": {
"MetricReportDefinitions": [
{
"@odata.id": "/Redfish/v1/TelemetryService/MetricReportDefinitions/PowerMetrics"
},
{
"@odata.id": "/Redfish/v1/TelemetryService/MetricReportDefinitions/CPUSensor"
}
]
}
}
Please provide ratings (1-5 stars).