Dell iDRAC Telemetry Reference Guide
Storage Disk SMART Data
The Storage Disk SMART Data feature shows whether SMART (Self-Monitoring Analysis and Reporting Technology) is enabled or disabled for disks, with options including Detect-Only, Enabled, and Disabled.
| Metric Ids | Description | Metric Type | Units | Sensing Interval in seconds |
|---|---|---|---|---|
| UsedReservedBlockCount | SMART_ID_179: Count of used reserved blocks. This value is not normalized. | Counter | Not Applicable | 3600 |
| UncorrectableLBACount | SMART_ID_198: The total count of uncorrectable errors when reading/writing a sector (LBA). This value is not normalized. | Counter | Not Applicable | 3600 |
| VolatileMemoryBackupSourceFailures | SMART_ID_201: Volatile memory backup source failures. This value is not normalized | Counter | Not Applicable | 3600 |
| EraseFailCount | SMART_ID_182: Erase fail count. This value is not normalized. | Counter | Not Applicable | 3600 |
| CommandTimeout | SMART_ID_188: The number of aborted operations due to disk timeout. This value is not normalized | Counter | Not Applicable | 3600 |
| ExceptionModeStatus | SMART_ID_202: Exception mode status. This value is not normalized. | Numeric | Not Applicable | 3600 |
| UnusedReservedBlockCount | SMART_ID_180: Count of unused reserved blocks. This value is not normalized. | Counter | Not Applicable | 3600 |
| UncorrectableErrorCount | SMART_ID_187: The count of errors that could not be recovered using hardware ECC. This value is not normalized | Counter | Not Applicable | 3600 |
| DriveTemperature | SMART_ID_194: Drive temperature in Celsius. This value is not normalized. | Numeric | Celsius (Cel) | 3600 |
| ReallocatedBlockCount | SMART_ID_05: Count of reallocated blocks/sectors. The raw value represents a count of the bad blocks/sectors that have been found and remapped. This value is not normalized. | Counter | Not Applicable | 3600 |
| ECCERate | SMART_ID_13: Uncorrected read errors reported to the OS. This value is not normalized. | Numeric | Not Applicable | 3600 |
| PercentDriveLifeRemaining | SMART_ID_245: Drive life remaining in percent. This value is not normalized. | Countdown | Percentage (%) | 3600 |
| PowerCycleCount | SMART_ID_12: This attribute indicates the count of full hard disk power on/off cycles. This value is not normalized | Counter | Not Applicable | 3600 |
| PowerOnHours | SMART_ID_09: The raw value of this attribute shows total count of hours (or minutes, or seconds, depending on manufacturer) in power-on state. This value is not normalized | Counter | Not Applicable | 3600 |
| MediaWriteCount | SMART_ID_233: Media (SSD) write count (a wearout indicator). This value is not normalized. | Counter | Not Applicable | 3600 |
| CurrentPendingSectorCount | SMART_ID_197: Current pending sector count. This value is not normalized | Counter | Not Applicable | 3600 |
| ReadErrorRate | SMART_ID_01: Read error rate (vendor specific). This value is not normalized. | Numeric | Not Applicable | 3600 |
| CRCErrorCount | SMART_ID_199: The count of errors in data transfer via the interface cable as determined by ICRC (Interface Cyclic Redundancy Check). This value is not normalized | Counter | Not Applicable | 3600 |
| ProgramFailCount | SMART_ID_181: The number of times when write (program the flash) to a flash memory failed. In case of HDD, this is the number of user data accesses (both reads and writes) where LBAs are not 4 KiB aligned. This value is not normalized. | Counter | Not Applicable | 3600 |
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\