Dell PowerEdge XR4000z Installation and Service Manual

PDF

Thermal restriction matrix

Table 1. XR4000z chassis - RAF Configuration Matrix The table describes the RAF configuration matrix for the XR4000z chassis type:
CPU Type HSK type Fan type RAF Configurations
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
Intel® Xeon® D - 2796NT, 20C,120 W Vapor Chamber (VC) HSK Standard (STD) fan Yes Yes Yes
Intel® Xeon® D - 2776NT, 16C, 117 W Yes Yes Yes
Intel® Xeon® D - 2753NT, 12C, 87 W Yes Yes Yes
Intel® Xeon® D - 2733NT, 8C, 80 W Yes Yes Yes
Intel® Xeon® D - 2712T, 4C, 65 W Yes Yes Yes

PCI-E Card Support

Table 2. XR4000z PCI-E Card Support Thermal Limitation (RAF Configurations) The table describes PCI-E Card Support Thermal Limitation (RAF Configurations) for XR4000z chassis:
PCI-E Type RAF Configurations
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
NVIDIA GPGPU A2 Not Supported Yes
NVIDIA GPGPU A30 Yes
Table 3. M.2 Support Thermal Limitation for XR4000z chassis (RAF Configurations)The table describes M.2 Support Thermal Limitation for XR4000z chassis (RAF Configurations).
M.2 Type Riser Module Mancini Module AIC Card M.2 Module (Witness Sled)
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C) Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C) Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C) Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
Micron 480 GB Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No
Micron 800 GB Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No
Micron 960 GB Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Micron 1.92 TB Throttling Active Yes Yes No No No Yes Yes Yes No No No
Micron 3.84 TB Throttling Active Yes Yes No No No Yes Yes Yes No No No
Hynix 480 GB Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No
Hynix 800 GB Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No
Hynix 960 GB Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
Hynix 1.92 TB Yes Yes Yes No No No Yes Yes Yes No No No
Hynix 3.84 TB Yes Yes Yes No No No Yes Yes Yes No No No
Table 4. XR4000w Processor Support Thermal Limitation for XR4000z chassis (RAF Configurations) The table describes the Witness Processor Support thermal restriction for the XR4000z chassis type:
CPU Type HSK type Fan type RAF Configurations
Edge 2 (Max 55°C) Edge 1 (Max 50°C) ASHRAE A4 (Max 45°C)
Intel Atom C3508, 4 cores, 11.5 W Aluminum extrusion Fan Yes Yes Yes

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\