PowerEdge Servers Error and Event Messages Reference Guide
MEM—Memory Event Messages
MEM0000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Persistent correctable memory errors detected on a memory device at location(s) arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory is operational. This is an early indicator of a possible future uncorrectable error.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Multi-bit memory errors are detected on the memory device at location(s) arg1. Immediately replace the DIMM.
- Arguments
- arg1 = location
- Detailed Description
- The memory has an uncorrectable error. System performance may be degraded and the operating system and/or applications may fail as a result of this.
- Recommended Response Action
- Immediately replace the DIMM.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Multi-bit memory error on <location>. Reseat memory
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Parity memory errors detected on a memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory is operational. This is an early indicator of a possible future uncorrectable error.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Stuck bit memory error detected on a memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory is operational. This is an early indicator of a possible future uncorrectable error.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is disabled.
- Arguments
- arg1 = location
- Detailed Description
- The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
- Recommended Response Action
- Re-install the memory component. Review product documentation for supported memory configurations. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Persistent correctable memory error limit reached for a memory device at location(s) arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory is operational. This is an early indicator of a possible future uncorrectable error.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Persistent correctable memory error limit reached for <location>. Reseat memory.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is present.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unsupported memory configuration; check memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
- Recommended Response Action
- Review product documentation for supported memory configurations.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Unsupported memory configuration. Check memory <location>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is spare memory.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is throttled.
- Arguments
- arg1 = location
- Detailed Description
- System performance is degraded.
- Recommended Response Action
- If unexpected, review system logs for power or thermal exceptions.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is overheating.
- Arguments
- arg1 = location
- Detailed Description
- System performance is degraded.
- Recommended Response Action
- If unexpected, review system logs for power or thermal exceptions.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Memory device <location> is over heating. Check fans
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location(s) arg1 is operating correctly.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0020
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is enabled.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0021
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Persistent correctable memory error limit reset for a memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0022
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is absent.
- Arguments
- arg1 = location
- Detailed Description
- The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
- Recommended Response Action
- If unexpected, check presence, then re-install.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0024
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is no longer spare memory.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0025
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- DDFS is disabled due to a problem with the NVRAM subsystem.
- Detailed Description
- An issue is detected with an NVRAM card, resulting in disablement of DDFS.
- Recommended Response Action
- Contact your service provider / tech support to resolve the issue.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
MEM0026
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A hardware fault was detected with an NVRAM card and it may need to be replaced.
- Detailed Description
- One or more issues or faults were detected with an NVRAM card and the card may need to be replaced.
- Recommended Response Action
- Contact your service provider / tech support to resolve the issue.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
MEM0600
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device was added at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0601
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device is removed from location arg1.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0700
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The persistent correctable memory error rate is at normal levels for a memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0701
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Correctable memory errors detected for arg1.
- Arguments
- arg1 = location
- Detailed Description
- Memory is operational. System detected and corrected memory errors.
- Recommended Response Action
- Reboot the system to enable potential memory self-healing. Ensure BIOS is up to date. If problem persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- LCD Message
- Correctable memory errors detected for <location>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0702
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Correctable memory errors detected for arg1.
- Arguments
- arg1 = location
- Detailed Description
- Memory is operational. System detected and corrected memory errors.
- Recommended Response Action
- Reboot the system to enable potential memory self-healing. Ensure BIOS is up to date. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Correctable memory errors detected for <location>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0802
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The memory health monitor feature has detected a degradation in the DIMM installed in arg1. Reboot system to initiate self-heal process.
- Arguments
- arg1 = location
- Detailed Description
- The memory health monitor feature has detected a degradation in the DIMM installed in the slot identified in the message. Reboot system to initiate self-heal process.
- Recommended Response Action
- The system memory health must be improved by initiating the self-heal process. To start the process, restart the system.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Reboot system to initiate self-healing at DIMM <location>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0804
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The self-heal operation successfully completed at DIMM arg1.
- Arguments
- arg1 = location
- Detailed Description
- The self-heal operation successfully completed on the memory module.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM0805
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the self-heal operation of the memory in the DIMM installed in arg1 because of internal issues. Replace the DIMM during the next planned service operation.
- Arguments
- arg1 = location
- Detailed Description
- The self-heal operation of the memory in the DIMM installed in the location identified in the message cannot be completed because of internal issues.
- Recommended Response Action
- Replace the DIMM during the next planned service operation.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Self-healing failed at DIMM <location>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 transition to a running state.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 failed to transition to a running state.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- LCD Message
- Memory device <location> failed to transition to a running state. Reseat memory
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is in test.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 failed to transition to in test.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is powered off.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 failed to power off.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Re-attempt memory removal process.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is online.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 failed to transition to online.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Re-attempt memory removal process.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is offline.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 failed to transition to offline.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Re-attempt memory removal process.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is off-duty.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is on-duty.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is in a degraded state.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is in a full state.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is in a power save state.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is in a power active state.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is not installed correctly.
- Arguments
- arg1 = location
- Detailed Description
- The memory may not be seated correctly, misconfigured, or has failed. Memory size is reduced.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Memory <location> is not installed correctly. Re-install
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1017
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device at location arg1 is installed correctly.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1200
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory RAID is redundant.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1201
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory RAID redundancy is lost. Check memory device at location(s) arg1.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Memory RAID lost on <location>. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1202
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory RAID redundancy is degraded. Check memory device at location(s) arg1.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Re-install the memory component. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1203
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory is not redundant.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1204
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory mirror is redundant.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1205
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory mirror redundancy is lost. Check memory device at location(s) arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory may not be seated correctly, misconfigured, or has failed.
- Recommended Response Action
- Review system logs for memory exceptions. Re-install memory at location <location>.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Memory mirror lost on <location>. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1206
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory mirror redundancy is degraded. Check memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory may not be seated correctly, misconfigured, or has failed.
- Recommended Response Action
- Review system logs for memory exceptions. Re-install memory at location <location>.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1207
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory spare is redundant.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1208
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory spare redundancy is lost. Check memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- The assigned spare is no longer available.
- Recommended Response Action
- Review system logs for memory exceptions. Re-install memory at location <location>.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Memory spared lost on <location>. Power cycle system
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1209
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory spare redundancy is degraded. Check memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1210
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory is redundant.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1212
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory redundancy is lost.
- Detailed Description
- The memory may not be seated correctly, misconfigured, or has failed.
- Recommended Response Action
- Review system logs for memory exceptions. Re-install memory at location <location>.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM1214
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory redundancy is degraded.
- Detailed Description
- The memory may not be seated correctly, misconfigured, or has failed.
- Recommended Response Action
- Review system logs for memory exceptions. Re-install memory at location <location>.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM5100
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An operation has completed successfully in the memory device at arg1. The server and device is operating normally. Extended ID: arg2.
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- An operation has completed successfully in the memory device at the location identified in the message.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM5101
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic event occurred in the memory device at arg1. Check the device and system configuration. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic event occurred in the memory device at location identified in the message. The device may be operating in a degraded state. Checking the device and system configuration is recommended for remediation.
- Recommended Response Action
- Make sure that the server and device configuration is as per the recommendations in the respective PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM5102
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic event occurred in the memory device at arg1. Reseat the device. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic event occurred in the memory device at location identified in the message. Reseating the device is recommended for remediation. Contact technical support if problem persists.
- Recommended Response Action
- Manually reseat the memory device. For instructions about reseating, see the respective servers PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM5103
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic event occurred in the memory device at arg1. Perform a warm reboot. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic event occurred in the memory device at location identified in the message. Performing a warm reboot is recommended for remediation. System will attempt to perform self-healing or self-correction.
- Recommended Response Action
- Perform a warm reboot to allow server to attempt self-healing or self-correction. If a warm reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM5104
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic event occurred in the memory device at arg1. Perform a cold reboot. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic event occurred in the memory device at location identified in the message. Performing a cold reboot is recommended for remediation. System will attempt to perform self-healing or self-correction.
- Recommended Response Action
- Perform a cold reboot to allow server to attempt self-healing or self-correction. If a cold reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM5107
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic event occurred in the memory device at arg1. Retry operation. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic event occurred in the memory device at location identified in the message. The attempted operation on this device has failed. Retry operation.
- Recommended Response Action
- Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM5109
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic event occurred in the memory device at arg1. The device is cryptographically locked. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic event occurred in the memory device at location identified in the message. The device is cryptographically locked. Attempt to re-enter the encryption passphrase to unlock or Secure Erase the device to cryptographically erase all data and restore unrestricted access to the device.
- Recommended Response Action
- Do one of the following: 1) Try to unlock the device by entering the encryption passphrase. 2) Perform a Secure Erase operation on the device to cryptographically erase all data, and then restore an unrestricted access to the device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM5199
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An unknown diagnostic event occurred in the memory device at arg1. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- An unknown diagnostic event occurred in the memory device at location identified in the message. iDRAC firmware must be updated to properly decode this event.
- Recommended Response Action
- Update iDRAC firmware to the latest version available. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM6000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device monitoring is disabled.
- Detailed Description
- The memory module may not be correctly seated, wrongly configured, or has failed.
- Recommended Response Action
- Review the Embedded System Management (ESM) Log for memory exceptions. Re-install the memory modules.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- OMSA Event ID
- 5400
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
MEM6001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device status is unknown. Memory device location: arg1, Possible memory module event cause: arg2.
- Arguments
- arg1 = location
- arg2 = cause
- Detailed Description
- The memory module may not be correctly seated, wrongly configured, or has failed.
- Recommended Response Action
- Review the Embedded System Management (ESM) Log for memory exceptions. Re-install the memory modules at the identified location .
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- OMSA Event ID
- 5401
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
MEM6002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device status is normal. Memory device location: arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory device identified in the message has returned to a normal state.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- OMSA Event ID
- 5402
- OMSA Trap ID
- 5402
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
MEM6003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device status is non-critical. Memory device location: arg1, Possible memory module event cause: arg2.
- Arguments
- arg1 = location
- arg2 = cause
- Detailed Description
- The memory module may not be correctly seated, wrongly configured, or has failed.
- Recommended Response Action
- Review the Embedded System Management (ESM) Log for memory exceptions. Re-install the memory modules at the identified location .
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- OMSA Event ID
- 5403
- OMSA Trap ID
- 5403
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
MEM6004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device status is critical. Memory device location: arg1, Possible memory module event cause: arg2.
- Arguments
- arg1 = location
- arg2 = cause
- Detailed Description
- The memory module may not be correctly seated, wrongly configured, or has failed.
- Recommended Response Action
- Review the Embedded System Management (ESM) Log for memory exceptions. Re-install the memory modules at the identified location .
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- OMSA Event ID
- 5404
- OMSA Trap ID
- 5404
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
MEM6005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory device has failed. Memory device location: arg1, Possible memory module event cause: arg2.
- Arguments
- arg1 = location
- arg2 = cause
- Detailed Description
- The memory module failed because of an irrecoverable error.
- Recommended Response Action
- Review the Embedded System Management (ESM) Log for memory exceptions. Remove the old memory module and install a new memory module at the identified location .
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- OMSA Event ID
- 5405
- OMSA Trap ID
- 5405
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
MEM6101
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic warning event occurred in the memory device at arg1. Check the device and system configuration. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic warning event occurred in the memory device at location identified in the message. The device may be operating in a degraded state. Checking the device and system configuration is recommended for remediation.
- Recommended Response Action
- Make sure that the server and device configuration is as per the recommendations in the respective PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Warning event at <location>. Check memory config.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM6102
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic warning event occurred in the memory device with Serial No: arg1 and Part No: arg2 at arg3. Reseat the device (Extended ID: arg4).
- Arguments
- arg1 = serialNo
- arg2 = partNo
- arg3 = location
- arg4 = code
- Detailed Description
- A diagnostic warning event occurred in the memory device at location identified in the message. Reseating the device is recommended for remediation. Contact technical support if problem persists.
- Recommended Response Action
- Manually reseat the memory device. For instructions about reseating, see the respective servers PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Warning event at <location>. Reseat device.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM6104
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic warning event occurred in the memory device with Serial No: arg1 and Part No: arg2 at arg3. Perform a cold reboot(Extended ID: arg4).
- Arguments
- arg1 = serialNo
- arg2 = partNo
- arg3 = location
- arg4 = code
- Detailed Description
- A diagnostic warning event occurred in the memory device at location identified in the message. Performing a cold reboot is recommended for remediation. System will attempt to perform self-healing or self-correction.
- Recommended Response Action
- Perform a cold reboot to allow server to attempt self-healing or self-correction. If a cold reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Warning event at <location>. Cold reboot system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM6106
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic warning event occurred in the memory device at arg1 (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic warning event occurred in the memory device at location identified in the message. System will automatically attempt to perform self-healing or self-correction at next opportunity.
- Recommended Response Action
- Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Warning event at <location>. Contact service if persistent.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM6107
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic warning event occurred in the memory device at arg1. Retry operation. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic warning event occurred in the memory device at location identified in the message. The attempted operation on this device has failed. Retry operation.
- Recommended Response Action
- Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Warning event at <location>. Retry operation.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM6110
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic warning event occurred in the memory device at arg1. Update device firmware. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic warning event occurred in the memory device at location identified in the message. Update the firmware for the memory device to enable new features or address known issues.
- Recommended Response Action
- Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Warning event at <location>. Update device firmware.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM6114
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A diagnostic warning event occurred in the memory device at arg1 (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A diagnostic warning event occurred in the memory device at location identified in the message.
- Recommended Response Action
- If the issue persists,Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Warning event at <location>. Contact service provider.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM6199
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An unknown diagnostic warning event occurred in the memory device at arg1. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- An unknown diagnostic warning event occurred in the memory device at location identified in the message. iDRAC firmware must be updated to properly decode this event.
- Recommended Response Action
- Update iDRAC firmware to the latest version available. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Unknown warning event at <location>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The memory riser mismatch was corrected.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A hardware mismatch detected for memory riser.
- Detailed Description
- No detailed description available.
- Recommended Response Action
- Review product documentation for proper memory riser installation and configuration.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Memory riser mismatch detected. Check memory riser
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7101
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical diagnostic event occurred in the memory device at arg1. Check the device and system configuration. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A critical diagnostic event occurred in the memory device at location identified in the message. The device may be operating in a degraded state. Checking the device and system configuration is recommended for remediation.
- Recommended Response Action
- Make sure that the server and device configuration is as per the recommendations in the respective PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Critical event at <location>. Check memory config.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7102
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical diagnostic event occurred in the memory device at arg1. Reseat the device. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A critical diagnostic event occurred in the memory device at location identified in the message. Reseating the device is recommended for remediation. Contact technical support if problem persists.
- Recommended Response Action
- Manually reseat the memory device. For instructions about reseating, see the respective servers PowerEdge servers Installation and Service Manual available on the support site. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Critical event at <location>. Reseat device.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7104
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical diagnostic event occurred in the memory device at arg1. Perform a cold reboot. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A critical diagnostic event occurred in the memory device at location identified in the message. Performing a cold reboot is recommended for remediation. System will attempt to perform self-healing or self-correction.
- Recommended Response Action
- Perform a cold reboot to allow server to attempt self-healing or self-correction. If a cold reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Critical event at <location>. Cold reboot system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7107
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical diagnostic event occurred in the memory device at arg1. Retry operation. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A critical diagnostic event occurred in the memory device at location identified in the message. The attempted operation on this device has failed. Retry operation.
- Recommended Response Action
- Retry the operation. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Critical event at <location>. Retry operation.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7108
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical diagnostic event occurred in the memory device at arg1. Sanitize the device. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A critical diagnostic event occurred in the memory device at location identified in the message. The memory device has detected an error during startup that either cannot be recovered or has been moved from another server, which has resulted in a unusable configuration data.
- Recommended Response Action
- To recover the device, sanitize the memory device. Sanitizing the device will destroy all data on the device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Critical event at <location>. Sanitize device.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7110
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical diagnostic event occurred in the memory device at arg1. Update device firmware. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- A critical diagnostic event occurred in the memory device at location identified in the message. Update the firmware for the memory device to enable new features or address known issues.
- Recommended Response Action
- Update the memory device firmware to enable new features and resolve any known issues. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Critical event at <location>. Update device firmware.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7114
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A critical diagnostic event occurred in the memory device with Serial No: arg1 and Part No: arg2 at arg3 (Extended ID: arg4).
- Arguments
- arg1 = serialNo
- arg2 = partNo
- arg3 = location
- arg4 = code
- Detailed Description
- A critical diagnostic event occurred in the memory device at location identified in the message.
- Recommended Response Action
- If the issue persists,Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Critical event at <location>. Contact service provider.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM7199
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An unknown critical diagnostic event occurred in the memory device at arg1. (Extended ID: arg2).
- Arguments
- arg1 = location
- arg2 = code
- Detailed Description
- An unknown critical diagnostic event occurred in the memory device at location identified in the message. iDRAC firmware must be updated to properly decode this event.
- Recommended Response Action
- Update iDRAC firmware to the latest version available. If the issue persists,Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Unknown critical event at <location>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, LCD, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM8000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Correctable memory error logging disabled for a memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- Errors are being corrected but predicitive failure algorith is unable to run at optimal conditions. please update BIOS to fix issue.
- Recommended Response Action
- Please update to latest BIOS an update was added which aliviates this issue.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- SBE log disabled on <location>. Reseat memory
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM8001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Persistent correctable memory error logging enabled for a memory device at location arg1.
- Arguments
- arg1 = location
- Detailed Description
- No detailed description available.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM8500
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Low memory condition detected.
- Detailed Description
- A low memory condition was detected. If this condition continues, a failover or a reset may occur. If multiple resets occur, contact your service provider.
- Recommended Response Action
- If multiple resets occur, If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Audit (MEM = Memory)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM8501
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Low memory warning, arg1KB, arg2KB.
- Arguments
- arg1 = total memory size
- arg2 = threshold value
- Detailed Description
- A low memory condition was detected. If this condition continues, a failover or a reset may occur.
- Recommended Response Action
- If multiple resets occur, If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Audit (MEM = Memory)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM8502
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- ECC Memory error rate failover condition detected.
- Detailed Description
- An ECC memory condition was detected on the primary CMC and a failover was initiated.
- Recommended Response Action
- Reseat the primary CMC and initiate a failover back to the primary CMC. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- Audit (MEM = Memory)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM8503
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Usage of high memory arg1 KB is detected for storage management module.
- Arguments
- arg1 = total memory size
- Detailed Description
- Usage of high memory is detected for storage management module.
- Recommended Response Action
- Reset the primary CMC and initiate failover back to the primary CMC.
- Category
- Audit (MEM = Memory)
- Severity
- Warning
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- No alerts are applicable for this message
MEM9000
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory interconnect degraded.
- Detailed Description
- An issue is detected in the propagation of signals between the processor and the memory.
- Recommended Response Action
- Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Memory interconnect degraded. Reseat memory riser.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9001
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory interconnect is functioning normally.
- Detailed Description
- The memory interconnect is functioning normally.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- LCD Message
- Memory interconnect normal.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9002
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Intel QPI interconnect arg1 has a correctable error.
- Arguments
- arg1 = number
- Detailed Description
- A correctable error was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message.
- Recommended Response Action
- Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Intel QPI interconnect <number> has a correctable error.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9003
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Intel SMI 2 Memory interconnect arg1 has a correctable error.
- Arguments
- arg1 = number
- Detailed Description
- A correctable error was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
- Recommended Response Action
- Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Intel SMI 2 Memory interconnect <number> has a correctable error.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9004
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Intel QPI interconnect arg1 has degraded.
- Arguments
- arg1 = number
- Detailed Description
- A link degradation was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message. The system will continue to operate at reduced performance.
- Recommended Response Action
- Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Intel QPI interconnect <number> has degraded. Reseat processor.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9005
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Intel SMI 2 Memory interconnect arg1 has degraded.
- Arguments
- arg1 = number
- Detailed Description
- A link degradation was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
- Recommended Response Action
- Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Intel SMI 2 interconnect <number> degraded. Reseat memory riser.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9006
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Intel QPI interconnect arg1 has a non-recoverable issue.
- Arguments
- arg1 = number
- Detailed Description
- A non-recoverable link issue was detected in propagation of signals between processors through the Intel QPI interconnect interconnect identified in the message.
- Recommended Response Action
- Do one of the following: 1) Restart the server and check whether the issue persists. 2) If the issue is not resolved by the preceding action, reseat the processors and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Intel QPI interconnect <number> has fatal error. Reseat memory riser.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9007
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Intel SMI 2 Memory interconnect arg1 has a non-recoverable issue.
- Arguments
- arg1 = number
- Detailed Description
- A non-recoverable link issue was detected in propagation of signals between processor and memory through the Intel SMI 2 memory interconnect identified in the message.
- Recommended Response Action
- Do one of the following: 1) Reseat the memory riser and restart the server. 2) If the issue is not resolved by preceding action, reseat the processor and restart the server. 3) If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Intel SMI 2 interconnect <number> has fatal error. Reseat mem riser.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9008
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Intel DDR Memory interconnect arg1 has a non-recoverable issue.
- Arguments
- arg1 = number
- Detailed Description
- A non-recoverable issue was detected in the propagation of signals on the Intel DDR memory interconnect identified in the message.
- Recommended Response Action
- Reseat all DIMMs on the memory riser, reseat the memory riser, and restart the server. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Intel DDR interconnect <number> has fatal error. Reseat mem riser.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9009
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Intel DDR Memory interconnect arg1 has a correctable error.
- Arguments
- arg1 = number
- Detailed Description
- A correctable error was detected in the propagation of signals on the Intel DDR memory interconnect identified in the message.
- Recommended Response Action
- Do the following: 1) Reseat all DIMMs on the memory riser, 2) Reseat the memory riser, and 3) Restart the server. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Intel DDR interconnect <number> has a correctable error. Reseat mem riser.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9010
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A QuickPath Interconnect (QPI) Reference Code warning message code is logged.
- Detailed Description
- BIOS logged the major and minor code of a QuickPath Interconnect (QPI) Reference Code warning. This information can be reviewed by using a tool which displays raw IPMI SEL log data such as IPMItool with the -vvv option or RACADM with the -E option.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9011
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- QuickPath Interconnect (QPI) Reference Code warning location information is logged.
- Detailed Description
- BIOS logged location information of a QuickPath Interconnect (QPI) warning. This information can be reviewed by using a tool which displays raw IPMI SEL data such as IPMItool with the -vvv option or RACADM with the -E option.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- LCD Message
- QuickPath Interconnect (QPI) reference code warning.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9012
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Memory Reference Code (MRC) warning code is logged.
- Detailed Description
- BIOS logged the major and minor code of a Memory Reference Code (MRC) warning. This information can be reviewed by using a tool which displays raw IPMI SEL data such as IPMI tool with the -vvv option or RACADM with the -E option.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9013
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Memory Reference Code (MRC) warning location information is logged.
- Detailed Description
- BIOS logged location information of a Memory Reference Code (MRC) warning. This information can be reviewed by using a tool which displays raw IPMI SEL data such as IPMItool with the -vvv option or RACADM with the -E option.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- LCD Message
- Memory Reference Code (MRC) warning.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9014
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A correctable memory error has occurred in Dual In-line Memory Module (DIMM) device arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory device identified in the message has encountered a correctable memory error. This may be an early indicator of a possible future uncorrectable error.
- Recommended Response Action
- This is a correctable error. Review log information and if multiple correctable errors have occurred on the DIMM identified in the message, re-install the memory device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- LCD Message
- DIMM <location> has a correctable memory error.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9015
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Multi-bit memory errors detected on a Dual In-line Memory Module (DIMM) device arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory device identified in the message has encountered a uncorrectable error. System performance may be degraded. The operating system and/or applications may fail as a result.
- Recommended Response Action
- Re-install the memory component identified in the message. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9016
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Correctable memory error rate exceeded for Dual In-line Memory Module (DIMM) arg1.
- Arguments
- arg1 = location
- Detailed Description
- The memory device identified in the message may not be operational. This an early indicator of a possible future uncorrectable error.
- Recommended Response Action
- Re-install the memory component identified in the message. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- LCD Message
- DIMM <location> exceeded correctable memory error rate.
- Redfish Event Type
- Not Applicable
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9020
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is about to reach the end of supported life duration.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot, identified in the message, is about to reach the end of supported life duration.
- Recommended Response Action
- During the next scheduled maintenance, replace the Non-Volatile Dual In-line Memory Module (NVDIMM) device. For more information about the usage of NVDIMMs, see the system Owners Manual on the support site.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- The NVDIMM in <location> is approaching the end of supported life.
- OMSA Event ID
- 5426
- OMSA Trap ID
- 5426
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9021
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) in slot arg1 is running the backup firmware image because the primary firmware has issues.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM in the slot identified in the message is running the backup firmware image because the primary firmware image has issues.
- Recommended Response Action
- Update the Non-Volatile Dual In-line Memory Module(NVDIMM) to the latest firmware. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- The NVDIMM in <location> is running backup firmware.
- OMSA Event ID
- 5426
- OMSA Trap ID
- 5426
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9022
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Non-Critical event was detected on the Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device identified in the message has encountered a Non-Critical event.
- Recommended Response Action
- If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- NVDIMM <location> has a Non-Critical event.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9030
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is not responding and is disabled.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message is not responding and is disabled.
- Recommended Response Action
- Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- The NVDIMM in <location> is not responding and has been disabled.
- OMSA Event ID
- 5427
- OMSA Trap ID
- 5427
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9031
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is unable to save the data during the previous system shutdown operation or power loss.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message is unable to save the data during the previous system shutdown operation or power loss. The NVDIMM is placed in write-protect mode.
- Recommended Response Action
- Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- The NVDIMM in <location> was not able to save its data and has been placed in write protect mode.
- OMSA Event ID
- 5428
- OMSA Trap ID
- 5428
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9032
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is unable to restore the data that was saved in the previous save operation.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message is unable to restore the data that was saved in the previous save operation. The NVDIMM is placed in write-protect mode.
- Recommended Response Action
- Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- The NVDIMM in <location> was not able to restore its data from its previous save operation and has been placed in write protect mode.
- OMSA Event ID
- 5429
- OMSA Trap ID
- 5429
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9033
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device is of unsupported configuration and unable to operate as currently configured.
- Detailed Description
- An NVDIMM device is of unsupported configuration and unable to operate as currently configured.
- Recommended Response Action
- Review the memory configuration and make sure the configuration is as per memory rules defined in the system Owners Manual on the support site.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Illegal NVDIMM configuration detected.
- OMSA Event ID
- 5430
- OMSA Trap ID
- 5430
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9034
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 is not responding.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message is not responding.
- Recommended Response Action
- Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- The NVDIMM in <location>is not responding.
- OMSA Event ID
- 5431
- OMSA Trap ID
- 5431
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9035
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 cannot be configured to save data during a power loss because of an issue in the NVDIMM.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message cannot be configured to save data during a power loss because of an issue in the NVDIMM.
- Recommended Response Action
- Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Unable to arm the NVDIMM in <location>.
- OMSA Event ID
- 5432
- OMSA Trap ID
- 5432
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9036
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) devices are placed in write-protect mode because the system may not provide sufficient power to save data in case of power loss.
- Detailed Description
- The NVDIMM devices are placed in write-protect mode because the server may not provide sufficient power or the battery is not sufficiently charged to save data in case of power loss.
- Recommended Response Action
- Review any preceding power or battery entries in the log and resolve the issues. Refer to your documentation for details on how to view the log.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- All NVDIMMs are placed in Wrte Protect mode.
- OMSA Event ID
- 5433
- OMSA Trap ID
- 5433
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9037
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 has reached the end of supported life duration and is placed in write-protect mode.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message has reached the end of supported life duration and is placed in write-protect mode.
- Recommended Response Action
- Replace the Non-Volatile Dual In-line Memory Module (NVDIMM) device. For information about removing and reinstalling the NVDIMM, see the system Owners Manual on the support site.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- The NVDIMM in <location> has reached the end of supported life.
- OMSA Event ID
- 5434
- OMSA Trap ID
- 5434
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9038
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 has lost persistency and is placed in write-protect mode.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message has lost persistency and is placed in write-protect mode.
- Recommended Response Action
- Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- The NVDIMM in <location> has lost persistency and is placed in write-protect mode.
- OMSA Event ID
- 5435
- OMSA Trap ID
- 5435
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9039
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 was unable to be initialized.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message was unable to clear its storage media as part of the initialization process and is disabled.
- Recommended Response Action
- Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- The NVDIMM in <location> was unable to be initialized and has been disabled.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9040
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- A Critical event was detected on the Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message has encountered a critical error. System performance may be degraded. The operating system and/or applications may fail as a result.
- Recommended Response Action
- Remove and reinstall the Non-Volatile Dual In-line Memory Module (NVDIMM) device. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Critical
- Trap/EventID
- 2265
- LCD Message
- Critical event on NVDIMM in slot <location>.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9050
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1 has regained persistency and is available for use.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message has regained persistency and is available for use.
- Recommended Response Action
- No response action required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- OMSA Event ID
- 5425
- OMSA Trap ID
- 5425
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9060
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The self-heal operation successfully completed on the memory module.
- Detailed Description
- The self-heal operation successfully completed on the memory module.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9061
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- An Information-Only event was detected on the Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1. The NVDIMM is operating normally.
- Arguments
- arg1 = location
- Detailed Description
- The NVDIMM device in the slot identified in the message is functioning normally.
- Recommended Response Action
- No response action is required.
- Category
- System Health (MEM = Memory)
- Severity
- Informational
- Trap/EventID
- 2267
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9070
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The erase operation on the non-volatile DIMM with serial number arg1 in slot arg2 is successfully completed.
- Arguments
- arg1 = serial number
- arg2 = slot number
- Detailed Description
- The erase operation for the specified DIMM completed successfully.
- Recommended Response Action
- No response action is required but it is recommended that the system be upgraded to the latest BIOS.
- Category
- Configuration (MEM = Memory)
- Severity
- Informational
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9071
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to complete the erase operation on the non-volatile DIMM with serial number arg1 in slot arg2.
- Arguments
- arg1 = serial number
- arg2 = slot number
- Detailed Description
- The erase operation could not be completed for the DIMM identified in the message.
- Recommended Response Action
- Retry the operation. If the issue persists, contact your service provider. It is also recommended that the system be upgraded to the latest BIOS.
- Category
- Configuration (MEM = Memory)
- Severity
- Critical
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9072
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- The system memory has detected an error on a memory transaction at the location arg1. Reboot the system for auto-healing.
- Arguments
- arg1 = location
- Detailed Description
- The system has detected a memory error which cannot be immediately corrected.The OS has been notified of the memory error location.Recommended action is to warm reboot the system to initiate auto-healing and to reinitialize memory for optimized performance.
- Recommended Response Action
- Perform a warm reboot to allow server to attempt self-healing or self-correction. If a warm reboot has already occurred subsequent to this message then no further action is required. If the issue persists, Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Trap/EventID
- 2266
- LCD Message
- Warning event at <location>. Warm reboot system.
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
- Applicable Event or Alert Types
- CMC—Not Applicable
MEM9073
NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the
Applicable Event or Alert Types section.
- Message
- Unable to update firmware on a Non-Volatile Dual In-line Memory Module (NVDIMM) device in the slot arg1.
- Arguments
- arg1 = location
- Detailed Description
- Unable to update firmware for the NVDIMM identified in the message.
- Recommended Response Action
- Retry the operation. If the issue not resolved, replace the NVDIMM, or If the issue persists,Collect a SupportAssist collection (TSR) report using iDRAC. Visit https://www.dell.com/support/incidents-online/contactus/dynamic to use the Virtual Assistant to analyze the collection and recommend a resolution.
- Category
- System Health (MEM = Memory)
- Severity
- Warning
- Redfish Event Type
- Alert
- Applicable Event or Alert Types
- iDRAC—Filter Visibility, Remote System Log, Redfish Eventing*, LC Log*
- Applicable Event or Alert Types
- CMC—Not Applicable