PowerEdge Servers Error and Event Messages Reference Guide

PDF

RFL—IDSDM Media Event Messages

RFL2000

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal Dual SD Module arg1 is present.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (RFL = IDSDM Media)
Severity
Informational
Trap/EventID
2211
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

RFL2002

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal Dual SD Module arg1 is offline.
Arguments
  • arg1 = name
Detailed Description
The SD card module is installed but may be improperly installed or configured incorrectly.
Recommended Response Action
Reinstall the SD module.
Category
System Health (RFL = IDSDM Media)
Severity
Warning
Trap/EventID
2210
LCD Message
Internal Dual SD Module <name> is offline.
OMSA Event ID
5303
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

RFL2003

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal Dual SD Module arg1 is online.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (RFL = IDSDM Media)
Severity
Informational
Trap/EventID
2211
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

RFL2004

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Failure detected on Internal Dual SD Module arg1.
Arguments
  • arg1 = name
Detailed Description
The SD card module is installed but improperly configured or failed to initialize.
Recommended Response Action
Reinstall the SD module and remove and reinstall SD cards.
Category
System Health (RFL = IDSDM Media)
Severity
Critical
Trap/EventID
2209
LCD Message
Internal Dual SD Module <name> failed. Check SD Card
OMSA Event ID
5300
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log, Power Off, Power Cycle, Reset
Applicable Event or Alert Types
CMC—Not Applicable

RFL2005

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal Dual SD Module arg1 is operating normally.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (RFL = IDSDM Media)
Severity
Informational
Trap/EventID
2211
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

RFL2006

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal Dual SD Module arg1 is write protected.
Arguments
  • arg1 = name
Detailed Description
The module is write-protected. Changes may not be written to the media.
Recommended Response Action
If unintended, remove the media and disable write protection.
Category
System Health (RFL = IDSDM Media)
Severity
Warning
Trap/EventID
2210
LCD Message
Internal Dual SD Module <name> is write protected. Check SD Card
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

RFL2007

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal Dual SD Module arg1 is writable.
Arguments
  • arg1 = name
Detailed Description
No detailed description available.
Recommended Response Action
No response action is required.
Category
System Health (RFL = IDSDM Media)
Severity
Informational
Trap/EventID
2211
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

RFL2008

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal Dual SD Module arg1 is disabled.
Arguments
  • arg1 = name
Detailed Description
The Internal Dual SD Card redundancy feature was disabled. The SD card identified in the message is disabled.
Recommended Response Action
No response action is required.
Category
System Health (RFL = IDSDM Media)
Severity
Informational
Trap/EventID
2211
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

RFL2009

NOTE: Event or Alert types that are enabled by default are identified using an asterisk (*) symbol in the Applicable Event or Alert Types section.
Message
Internal Dual SD Module arg1 is enabled.
Arguments
  • arg1 = name
Detailed Description
The Internal Dual SD Card redundancy feature was enabled. The SD card identified in the message is enabled.
Recommended Response Action
No response action is required.
Category
System Health (RFL = IDSDM Media)
Severity
Informational
Trap/EventID
2211
Redfish Event Type
Alert
Applicable Event or Alert Types
iDRAC—Filter Visibility, IPMI Alert*, SNMP Alert, Email Alert, Remote System Log, WS Eventing, Redfish Eventing*, LC Log*, OS Log
Applicable Event or Alert Types
CMC—Not Applicable

Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\