Dell PowerStore Importing External Storage to PowerStore Guide
General requirements for importing data
The following requirements apply to PowerStore before running import:
- The global storage IP address for PowerStore must be configured.
- Verify that PowerStore and its nodes are in a healthy state.
The following requirements apply to all source platforms:
- (For non-disruptive import) You must have the
appropriate privileges on the source and its associated hosts to perform an import
to a PowerStore
cluster.
- For Windows-based systems, Administrator privilege is required to perform an import to a PowerStore cluster.
- For Linux-based systems, root privilege is required to perform an import to a PowerStore cluster.
- The size of any volume imported from a remote system to a PowerStore cluster must be a multiple of 8192 bytes.
- (For non-disruptive import) A Fibre Channel (FC) or iSCSI connection exists between the source system and each associated host system, and a matching FC or iSCSI connection exists between each associated host system and the PowerStore cluster. These connections to each host system should be of the same type, either all FC or all iSCSI.
- (For agentless import) For Dell
PowerMax or VMAX3, an FC connection exists between the source system and each
associated host system, and a matching FC connection exists between each associated
host system and the PowerStore cluster. For Dell Compellent Storage Center (SC)
or Unity, or Dell VNX2, XtremIO X1, XtremIO X2
source systems, or Universal source systems, the connections between the hosts and
the source system and between the hosts and the PowerStore cluster must be
either all over iSCSI or all over Fibre Channel (FC). NOTE:When FC connectivity between the host and source system and between the host and PowerStore cluster is used, the administrator must set up FC zoning between the host, the source system, and the PowerStore cluster.
- Only an iSCSI connection is supported between Dell SC (non-disruptive import for Linux only) source systems and the PowerStore cluster.
- Only an FC connection is supported between a Dell PowerMax or VMAX3 source system (agentless import) and the PowerStore cluster.
- Either an iSCSI connection or an FC connection is
supported between a Dell SC, or XtremIO X1, or X2
system, or Universal type systems (agentless import), or a Dell Unity or VNX2 (either
non-disruptive or agentless) source system and the PowerStore cluster. NOTE:When the connection between the Dell SC, or XtremIO X1, or X2 system, or Universal type systems (agentless import), or a Dell Unity or VNX2 (either non-disruptive or agentless) source system and the PowerStore cluster are over iSCSI, the connections between the hosts and the source system and between the hosts and the PowerStore cluster can be either all over iSCSI or all over FC. However, when the connections between those source systems and the PowerStore cluster are all over FC, the connections between the hosts and the source system and between the hosts and the PowerStore cluster must be all over FC.
- (For non-disruptive import) Only one instance of MPIO should be running on the host in order to perform an import.
- The PowerStore
Simple Support Matrix document at dell.com/powerstoredocs lists the host operating system platforms that
are supported for non-disruptive import. NOTE: Use the agentless import option to migrate the external storage to the PowerStore cluster in either of the following cases:
- The operating environment running on the source system does not match what is listed in the PowerStore Simple Support Matrix for non-disruptive import.
- The source system is a Dell XtremIO X1 or XtremIO X2, or PowerMax or VMAX3.
- When Fibre Channel (FC) connectivity is used between the host and the
PowerStore cluster, the administrator must set up FC zoning between the dual-mode FC ports to the destinations.
NOTE:For more information about FC zoning, see PowerStore Host Configuration Guide at dell.com/powerstoredocs.
- When Fibre Channel (FC) connectivity is used between
the source system and the PowerStore cluster, the administrator must
set up FC zoning between the source system and the PowerStore cluster. NOTE:For FC connections, it is recommended to configure FC zoning in such a way that PowerStore can connect to at least two distinct targets on each remote system controller from a PowerStore node. See PowerStore cluster fibre channel connectivity to source systems.
- (For non-disruptive import) Depending on the port
number that is selected for the hosts that are added when creating an import
session, that port must be open on the firewall. The predefined host ports for
Windows and Linux are:
- 8443 (default)
- 50443
- 55443
- 60443