Dell DL4000 Appliance Release Notes

PDF

Error displayed when remounting volumes

Description When recovering a DVM repository the following error is displayed: Failed read consistency lock on IsSpare_AC or MediaPresent_DiskDriveToStorageExtent_AC Association Cache . The error occurs when a repository was provisioned on several controllers and one of the mount points was removed.
  • NOTE: Ensure you use the PERC H710P Mini controller to provision storage.
Workaround/Solution
  1. Assign drive letters to volumes with storage locations of the repository.
  2. Manually restore Core settings or Open Existing Repository through the Repositories pane specifying valid paths for repositories.