About SSD read cache

Unlike tiering, where a single copy of specific blocks of data resides in either spinning disks or SSDs, the Read Flash Cache (RFC) feature uses one SSD read-cache disk group per pool as a read cache for frequently accessed data only. Each read-cache disk group consists of one or two SSDs with a maximum usable capacity of 4TB. A separate copy of the data is also kept in spinning disks. Read-cache content is lost when a controller restart or failover occurs. Taken together, these attributes have several advantages:

  • The performance cost of moving data to read-cache is lower than a full migration of data from a lower tier to a higher tier. ● Read-cache does not need to be fault tolerant, potentially lowering system cost.
  • Controller read cache is effectively extended by two orders of magnitude, or more. When a read-cache group consists of one SSD, it automatically uses NRAID. When a read-cache group consists of two SSDs, it automatically uses RAID 0.
NOTE:In the case of a drive failure within a read cache, the disk group will be deleted, and the remaining drive is returned to available. This allows for the drive to be replaced and the read-cache to be recreated.

For more information on SSDs, see About SSDs