Replace a failed
storage controller with
a replacement
storage controller.
Prerequisites
CAUTION: Do not
power down both
storage controllers. The other
storage controller continues to operate when the failed
storage controller is powered
down. If both
storage controllers are mistakenly powered down, restart the
storage system before
replacing the failed
storage controller.
About this task
The cover
of the
storage controller indicates which slot the
storage controller operates in.
Storage controller 1 goes into the top slot.
Storage controller 2 goes into the bottom slot.
Steps
Make sure that all cables plugged into the
storage controller are
labeled.
Disconnect the cables from the failed
storage controller.
Remove the failed
storage controller from
the chassis.
CAUTION: To prevent a thermal shutdown of the
storage system, the service
baffle must be installed within three minutes of removing the
storage controller.
Install the service baffle into the empty
slot in the chassis.
Perform the following on the failed
storage controller:
Remove the cover from the
storage controller, and
set it aside.
The label on the cover identifies the chassis slot
from which the failed
storage controller was removed.
Remove the I/O card, mezzanine card, and battery backup unit
from the failed
storage controller.
The I/O card, mezzanine card, and battery backup
unit are reinstalled in the replacement
storage controller.
Perform the following on the replacement
storage controller:
Remove the cover from the
storage controller.
Insert the I/O card, the mezzanine card, and battery backup unit
into the
storage controller.
Take the cover from the failed
storage controller, and
install it on the replacement
storage controller.
The label on the cover identifies the correct chassis
slot for the replacement
storage controller.
Remove the service baffle from the chassis.
CAUTION: To prevent a thermal shutdown of the
storage system, the
storage controller must
be installed within three minutes of removing the service baffle.
Install the replacement
storage controller in the
chassis.
Reconnect the cables to the
storage controller.
The
storage system reads configuration information from the disks, and the
storage controller is updated
to the same version of software that is running on the existing
storage controller.
NOTE: If the
Storage Center software
on the
storage controller is older than the software on the existing
storage controller, the
storage system updates
the
storage controller with the software version on the existing
storage controller. The
Storage Center software update on the
storage controller could
take 15 to 45 minutes to complete.
Clear the
storage controller swap
status from the
Hardware tab in
Dell Storage Manager
.
For instructions, see the
Dell Storage Manager
Administrator’s
Guide
.
Next steps
Use
Dell Storage Manager
to edit the
Storage Center settings and set the operation mode of the
Storage Center to Production mode.
Use
Dell Storage Manager
to send
SupportAssist information to
technical support
Data is not available for the Topic
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please provide ratings (1-5 stars).
Please select whether the article was helpful or not.
Comments cannot contain these special characters: <>()\