Expansion card installation guidelines
The following table describes the supported expansion cards:
Table 1. Expansion card riser configurationsThis table provides information about the expansion card riser configuration for
PowerEdge
R540 system.
Expansion card riser
|
PCIe slots on the riser
|
Processor connection
|
Height
|
Length
|
Slot width
|
Full height right riser
|
Slot 2
|
Processor 1
|
Full Height
|
Half Length
|
x16
|
Low profile right riser
|
Slot 2
|
Processor 1
|
Low Profile
|
Half Length
|
x16
|
Low profile left riser
|
Slot 3
|
Processor 2
|
Low Profile
|
Half Length
|
x16
|
Butterfly riser
|
Slot 2
|
Processor 1
|
Full Height
|
Half Length
|
x16
|
Butterfly riser
|
Slot 3
|
Processor 1
|
Low Profile
|
Half Length
|
x8
|
NOTE The expansion-card slots are not hot-swappable.
The following table provides guidelines for installing expansion cards to ensure proper cooling and mechanical fit. The expansion cards with the highest priority should be installed first using the slot priority indicated. All the other expansion cards should be installed in the card priority and slot priority order.
Table 2. Riser configurations: No RSR - 1 CPUThis table provides information about the slot priority for No RSR - 1 CPU configuration for
PowerEdge
R540 system.
Card Type
|
Slot Priority
|
Form factor
|
LOM riser ; 2x1G BCM5720L (ODM)
|
1
|
OCP
|
LOM riser ; 2x10G BCM57416 (BASeT/SFP+) (ODM)
|
1
|
OCP
|
PCIe SSD PCIe Card (Samsung/INTEL)
|
5
|
LP
|
Card, Network (Broadcom/INTEL/Mellanox/Solarflare)
|
5
|
LP
|
Card, Controller (EMULEX/QLOGIC)
|
5
|
LP
|
BOSS M.2 (SATA) (Dell)
|
5
|
LP
|
Card, Network (Broadcom/INTEL)
|
6, 5
|
LP
|
PERC9.14G (Foxconn)
|
Integrated Slot
|
FH or LP
|
HBA: External adapter
|
5
|
LP
|
RAID - PERC9.14G/PERC10 (Internal)/PERC11 (Dell)
|
Integrated Slot
|
FH or LP
|
Non-RAID - PERC11 (Internal) (Dell)
|
Integrated Slot
|
FH or LP
|
Non-RAID - PERC11 (External) (Dell)
|
5
|
LP
|
PERC 10 External adapter (Dell)
|
5
|
LP
|
Table 3. Riser configurations: No RSR - 2 CPUThis table provides information about the slot priority for No RSR - 2 CPU configuration for
PowerEdge
R540 system.
Card type
|
Slot priority
|
Form factor
|
LOM riser ; 2x1G BCM5720L (ODM)
|
1
|
OCP
|
LOM riser ; 2x10G BCM57416 (BASeT/SFP+) (ODM)
|
1
|
OCP
|
PCIe SSD PCIe Card (Samsung/INTEL)
|
4, 5
|
LP
|
Card, Network (Broadcom/INTEL/Mellanox/Solarflare)
|
4, 5
|
LP
|
Card, Controller (EMULEX/QLOGIC)
|
4, 5
|
LP
|
Intel OPA NIC (Intel OPA)
|
4
|
LP
|
BOSS M.2 (SATA) (Dell)
|
4, 5
|
LP
|
Card, Network (Braodcom/INTEL)
|
6, 5, 4
|
LP
|
PERC9.14G (Foxconn)
|
Integrated Slot
|
LP
|
HBA: External adapter
|
4, 5
|
LP
|
RAID - PERC9.14G/PERC10 (Internal)/PERC11 (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC11 (Internal) (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC11 (External) (Dell)
|
4, 5
|
LP
|
PERC 10 External adapter (Dell)
|
4, 5
|
LP
|
Table 4. Riser configurations: FH - 1 CPU and 2 CPUThis table provides information about the slot priority for FH - 1 CPU and 2 CPU riser configuration for
PowerEdge
R540 system.
Card type
|
Slot priority
|
Form factor
|
LOM riser ; 2x1G BCM5720L (ODM)
|
1
|
OCP
|
LOM riser ; 2x10G BCM57416 (BASeT/SFP+) (ODM)
|
1
|
OCP
|
PCIe SSD PCIe Card (Samsung/INTEL)
|
2
|
FH
|
NIC (Broadcom/INTEL/EMULEX/Mellanox/Solarflare)
|
2
|
FH
|
Card, Network (Broadcom/INTEL/Mellanox/INTEL)
|
2
|
FH
|
Card, Controller (EMULEX/QLOGIC)
|
2
|
FH
|
Intel OPA NIC (Intel OPA)
|
2
|
FH
|
BOSS M.2 (SATA) (Dell)
|
2
|
FH
|
PERC9.14G (Foxconn/Dell)
|
2
|
FH
|
PERC9.14G (Foxconn)
|
Integrated Slot
|
LP
|
RAID - PERC9.14G/PERC10 (Internal)/PERC 11 (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC 11 (Internal) (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC 11 (External) (Dell)
|
2
|
FH
|
RAID PERC10 (External) (Dell)
|
2
|
FH
|
PERC10 - External adapter (Dell)
|
2
|
FH
|
Table 5. Riser configurations: LP + LP - 2 CPU This table provides information about the slot priority for LP + LP - 2 CPU riser configuration for
PowerEdge
R540 system.
Card type
|
Slot priority
|
Form factor
|
LOM riser ; 2x1G BCM5720L (ODM)
|
1
|
OCP
|
LOM riser ; 2x10G BCM57416 (BASeT/SFP+) (ODM)
|
1
|
OCP
|
PCIe SSD PCIe Card (Samsung/INTEL)
|
3, 2
|
LP
|
Card, Network (Broadcom/INTEL/Mellanox/Solarflare)
|
3, 2
|
LP
|
Card, Controller (EMULEX/QLOGIC)
|
3, 2
|
LP
|
Intel OPA NIC (Intel OPA)
|
3, 2
|
LP
|
BOSS M.2 (SATA) (Dell)
|
3, 2
|
LP
|
PERC9.14G (Foxconn)
|
Integrated Slot
|
LP
|
HBA: External adapter
|
3, 2
|
LP
|
RAID - PERC9.14G/PERC10 (Internal)/PERC11 (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC11 (Internal) (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC11 (External) (Dell)
|
3, 2
|
LP
|
PERC 10 External adapter (Dell)
|
3, 2
|
LP
|
Table 6. Riser configurations: BTF + 3 XLP - 1 CPU This table provides information about the slot priority for BTF + 3 XLP - 1 CPU riser configuration for
PowerEdge
R540 system.
Card type
|
Slot priority
|
Form factor
|
LOM riser ; 2x1G BCM5720L (ODM)
|
1
|
OCP
|
LOM riser ; 2x10G BCM57416 (BASeT/SFP+) (ODM)
|
1
|
OCP
|
PERC9.14G/PERC10 (ODM)
|
2
|
FH
|
PERC9.14G/PERC10 (Dell)
|
2, 3, 5
|
FH
|
NIC (Broadcom/INTEL/Emulex/Mellanox/Solarflare)
|
2
|
FH
|
Card, Network (Broadcom/INTEL/Mellanox/Solarflare)
|
2
|
FH
|
Card, Controller (EMULEX/QLOGIC)
|
2
|
FH
|
BOSS M.2 (SATA) (Dell)
|
2
|
FH
|
PCIe SSD PCIe Card (Samsung/INTEL)
|
3, 2, 5
|
FH or LP
|
Card, Controller (QLOGIC/EMULEX)
|
3, 2, 5
|
FH or LP
|
Card, Network (Broadcom/INTEL/Mellanox/QLOGIC/Solarflare)
|
3, 5
|
LP
|
Card, Controller (QLOGIC)
|
3, 5
|
LP
|
Intel OPA NIC (Intel OPA)
|
2
|
FH
|
BOSS M.2 (SATA) (Dell)
|
3, 5
|
LP
|
Card, Network (Broadcom)
|
6, 5, 3
|
LP
|
Card, Network (INTEL)
|
6, 5, 3
|
LP
|
PERC9.14G (Foxconn)
|
Integrated Slot
|
NONE
|
RAID - PERC9.14G/PERC10 (Internal) (Dell)
|
Integrated Slot
|
NONE
|
HBA: External adapter
|
3, 5
|
LP
|
RAID - PERC9.14G/PERC10 (Internal)/PERC11 (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC11 (Internal) (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC11 (External) (Dell)
|
2, 3, 5
|
FH or LP
|
RAID - PERC 10 (External) (Dell)
|
2, 3, 5
|
FH
|
PERC 10 External adapter (Dell)
|
3, 5
|
LP
|
PERC 10 External adapter (Dell)
|
2, 3, 5
|
FH or LP
|
Table 7. Riser configurations: BTF + 3 XLP - 2 CPU This table provides information on the slot priority for BTF + 3 XLP - 2 CPU riser configuration for
PowerEdge
R540 system.
Card type
|
Slot priority
|
From Factor
|
LOM riser ; 2x1G BCM5720L (ODM)
|
1
|
OCP
|
LOM riser ; 2x10G BCM57416 (BASeT/SFP+) (ODM)
|
1
|
OCP
|
PERC9.14G/PERC10 (FXN)
|
2
|
FH
|
ERC9.14G/PERC10 (Dell)
|
2, 4, 3, 5
|
FH or LP
|
Broadcom NIC (Broadcom)
|
2
|
FH
|
Card, Network (Broadcom/INTEL)
|
2
|
FH
|
NIC (Intel/Emulex/Mellanox/Solarflare)
|
2
|
FH
|
Card, Controller (EMULEX/QLOGIC)
|
2
|
FH
|
Card, Network (Mellanox/QLOGIC/INTEL/Solarflare)
|
2
|
FH
|
BOSS M.2 (SATA) (Dell)
|
2
|
FH
|
PCIe SSD PCIe Card (Samsung)
|
3, 4, 2, 5
|
FH or LP
|
Card, Controller (QLOGIC)
|
3, 4, 2, 5
|
FH or LP
|
Card, Network (Broadcom/INTEL/Mellanox/QLOGIC)
|
4, 3, 5
|
LP
|
Card, Controller (EMULEX/QLOGIC)
|
4, 3, 5
|
LP
|
Intel OPA NIC (Intel OPA)
|
4
|
LP
|
Intel OPA NIC (Intel OPA)
|
2
|
FH
|
Card, Network (Solarflare)
|
4, 3, 5
|
LP
|
BOSS M.2 (SATA) (Dell)
|
4, 3, 5
|
LP
|
Card, Network (Broadcom/INTEL)
|
6, 5, 4, 3
|
LP
|
PERC9.14G (Foxconn)
|
Integrated Slot
|
NONE
|
RAID - PERC9.14G/PERC10 (Internal) (Dell)
|
Integrated Slot
|
NONE
|
HBA: External adapter
|
2, 4, 3, 5
|
LP
|
RAID - PERC9.14G/PERC10 (Internal)/PERC11 (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC11 (Internal) (Dell)
|
Integrated Slot
|
LP
|
Non-RAID - PERC11 (External) (Dell)
|
2, 4, 3, 5
|
FH or LP
|
RAID - PERC 10 (External) (Dell)
|
2
|
FH
|
PERC 10 External adapter (Dell)
|
4, 3, 5
|
LP
|
PERC 10 External adapter (Dell)
|
2, 4, 3, 5
|
FH or LP
|