Dell PowerEdge RAID Controller S140 User’s Guide

A Non-RAID virtual disk is no longer in first position in the BIOS configuration utility list after a system reboot

NOTE:When booting from a Non-RAID virtual disk, creating a virtual disk in OpenManage Server Administrator changes the virtual disk order and displaces the bootable Non-RAID virtual disk from the first position. PERC S140 then attempts to boot from the first virtual disk.
NOTE: A Non-RAID virtual disk can be created from Non-RAID physical disks—which are physical disks initialized by a controller other than PERC S140.
  1. When prompted at system startup, press Ctrl+R to access the BIOS configuration utility.
  2. Check Virtual Disks and determine if the bootable Non-RAID virtual disk is no longer in the first position.
  3. Use the Swap Two Virtual Disks option to swap the virtual disks and place the bootable Non-RAID virtual disk in the first position of the Virtual Disks field.