Dell PowerEdge RAID Controller S140 User’s Guide
A Non-RAID virtual disk is no longer in first position in the BIOS configuration utility list after a system reboot
NOTE:When booting from a
Non-RAID virtual disk, creating a virtual disk in OpenManage
Server Administrator changes the virtual disk order and displaces
the bootable Non-RAID virtual disk from the first position. PERC S140
then attempts to boot from the first virtual disk.
NOTE: A Non-RAID virtual
disk can be created from Non-RAID physical disks—which are physical disks initialized by a controller other than PERC S140.
- When prompted at system startup, press Ctrl+R to access the BIOS configuration utility.
- Check Virtual Disks and determine if the bootable Non-RAID virtual disk is no longer in the first position.
- Use the Swap Two Virtual Disks option to swap the virtual disks and place the bootable Non-RAID virtual disk in the first position of the Virtual Disks field.
Veuillez évaluer cet article (1 à 5 étoiles).
Veuillez évaluer cet article (1 à 5 étoiles).
Veuillez évaluer cet article (1 à 5 étoiles).
Avez-vous trouvé cet article utile?
Les commentaires ne peuvent pas contenir ces caractères spéciaux : <>()\