Dell Command | PowerShell Provider Version 2.7 User's Guide
Sample scripts
This section provides some exemplary sample scripts that depict the typical usage of Desired State Configuration using the functionality of Dell Command | PowerShell Provider for enforcing BIOS settings of the supported attributes. The scripts authored for Desired State Configuration should be saved in .ps1 format.
Enforcing simple configuration for category POSTBehavior
NOTE
Enforcing
‘Keypad’ attribute as ‘EnabledByNumlock’ on Node ’200.200.200.2’- Category property is mandatory field for each resource.
- BlockDefinition is a mandatory property only for the Powermanagement category. BlockDefinition must be unique for each resource block in the Powermanagement category.
Configuration POSTBehaviorConfiguration
{
Import-DscResource -ModuleName DellBIOSProvider
Node 200.200.200.2 {
POSTBehavior POSTBehaviorSettings #resource name
{
Category = "POSTBehavior"
Keypad = "EnabledByNumlock"
}
}
}
Configuring AdvancedBatteryChargeConfiguration in category Powermanagement
Configuration PowerManagementConfiguration
{
Import-DscResource -ModuleName DellBIOSProvider
Node 200.200.200.2 {
PowerManagement PowerManagementSettingsTuesday #resource name
{
Category = "PowerManagement"
BlockDefinition="1"
AdvancedBatteryChargeConfiguration = "Tuesday"
BeginningOfDay = "10:30"
WorkPeriod = "15:45"
}
PowerManagement PowerManagementSettingsSunday #resource name
{
Category = "PowerManagement"
BlockDefinition="2"
AdvancedBatteryChargeConfiguration = "Sunday"
BeginningOfDay = "13:30"
WorkPeriod = "15:45"
}
}
} Configuring PeakShiftDayConfiguration in category Powermanagement
Configuration PowerManagementConfigurationPeak
{
Import-DscResource -ModuleName DellBIOSProvider
Node localhost {
PowerManagement PowerManagementSettingsSaturday #resource name
{
Category = "PowerManagement"
BlockDefinition="1"
PeakShiftDayConfiguration = "Saturday"
StartTime = "10:30"
EndTime = "12:30"
ChargeStartTime = "13:30"
}
PowerManagement PowerManagementSettingsWednesday #resource name
{
Category = "PowerManagement"
BlockDefinition="2"
PeakShiftDayConfiguration = "Wednesday"
StartTime = "12:30"
EndTime = "15:30"
ChargeStartTime = "16:45"
}
}
}
Enforcing simple configuration for category POSTBehavior when BIOS password is set
NOTE When the BIOS password
is set on the client system, the password must be provided through
the 'Password' property.
Configuration POSTBehaviorConfiguration
{
Import-DscResource -ModuleName DellBIOSProvider
Node clientMachine01 {
POSTBehavior POSTBehaviorSettings #resource name
{
Category = "POSTBehavior"
Keypad = "EnabledByNumlock"
Password = “biospassword”
}
}
}NOTE For more sample scripts, see theDellBIOSProvider > DSC_SampleScripts