Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

Dell Chassis Management Controller Version 3.10 for PowerEdge VRTX RACADM CLI Guide

PDF

jobqueue

Table 1. Details of jobqueue. The following table provides the details of jobqueue attribute:
Description Displays the jobs in that are currently being run, delete the jobs, and create a job.
  • NOTE: To view the jobs, you must have CMC Login User privilege.
  • NOTE: To delete the jobs, you must have Chassis Configuration Administrator privilege.
Synopsis
racadm jobqueue view
racadm jobqueue delete
racadm jobqueue create 
Input
  • —i — Specifies the JobID that is displayed or deleted.
  • – –all — The JobIDs that are not applied are deleted.
  • <fqdd> — Specifies an FQDD for which a job has to be created.
  • reboot type — Specifies a reboot type. Valid options are none: No Reboot Job which is the default.
  • start time — Specifies a start time for job to be scheduled in yyyymmddhhmmss format. If you specify TIME_NOW, the job is immediately run.
  • Expiration time — Specifies the expiry time for the job to complete in yyyymmddhhmmss format. If you specify TIME_NA, the wait-time is not applicable for the job.
Example
  • Display all the jobs:
    -------------------------JOB QUEUE------------------------
                                                          [Job ID=RID_853106266329]
                                                          Job Name=Reboot4
                                                          Status=New
                                                          Start Time=[NOW]
                                                          Expiration Time=[NOW]
                                                          ----------------------------------------------------------
                                                          [Job ID=RID_852218430518]
                                                          Job Name=Reboot4
                                                          Status=New
                                                          Start Time=[NOW]
                                                          Expiration Time=[NOW]
                                                          ----------------------------------------------------------
                                                          [Job ID=RID_852215634901]
                                                          Job Name=Reboot4
                                                          Status=New
                                                          Start Time=[NOW]
                                                          Expiration Time=[NOW]
                                                          ----------------------------------------------------------
                                                          [Job ID=JID_852215394003]
                                                          Job Name=ConfigRAID:GUI:RAID.ChassisIntegrated.1-1
                                                          Status=New
                                                          Start Time=[NOW]
                                                          Expiration Time=[NOW]
                                                          ----------------------------------------------------------
                                                       
  • Delete the specified job:
    racadm jobqueue delete -i RID_860202993201
  • Job being created to turn on the RAID controller installed in the chassis.
    racadm jobqueue create RAID.ChassisIntegrated.1-1 -r pwrup -s TIME_NOW -e 20120501100000
  • racadm jobqueue delete -i <JobID>