Omitir para ir al contenido principal
  • Hacer pedidos rápida y fácilmente
  • Ver pedidos y realizar seguimiento al estado del envío
  • Cree y acceda a una lista de sus productos
  • Administre sus sitios, productos y contactos de nivel de producto de Dell EMC con Administración de la empresa.

Active System Manager Release 8.1.1 Installation Guide

PDF

Deployment Prerequisites

Specification Prerequisite

Connection Requirements

  • The virtual appliance is able to communicate with the out-of-band management network and any other networks from which you want to discover the resources.

  • The virtual appliance is able to communicate with the PXE network in which the appliance is deployed. It is recommended to configure the virtual appliance directly on the PXE network, and not on the external network.

  • The virtual appliance is able to communicate with the hypervisor management network.

  • The DHCP server is fully functional with appropriate PXE settings to PXE boot images from ASM in your deployment network.

Dell PowerEdge Servers

  • Dell PowerEdge Servers are configured and have the management IP address and login credentials assigned.
    • NOTE: The user name (root) and password required.
  • Any device being used in the boot order, such as C: Drive or NICs, must already be enabled in the boot order. This applies when booting to SD Card, Hard Disk, or FC, which are listed as C: in boot order or PXE and iSCSI, which are listed as NICs in the boot order. ASM will enable the supporting device connectivity and adjust the boot order, but cannot enable/disable device names in the boot order.

  • Before performing Fibre Channel boot from SAN, a server must be configured with the QLogic fiber channel card, which is configured with the appropriate scan selection. To verify this in the BIOS and QLogic device settings, press F2 for System Setup, and then go to Device Settings > <Target QLogic Fibre Channel adapter name> > Fibre Channel Target Configuration > Boot Scan , and then select " First LUN". The First LUN setting needs to be disabled for deployments other than Boot from SAN.

  • NOTE: For all servers prior to ASM discovery,make sure the RAID controller is enabled if it is available, and any unsupported 1Gb NICs are disabled.

    After updating these devices setting, you should restart the server to ensure that Lifecycle Controller system inventory is updated.

C-Series Server

  • Network and BIOS configuration cannot be done using appliance. You need to do it manually.
  • Hard disk should be available for server to install OS.

  • You need to set single NIC to PXE boot..This should be set as first boot device and hard disk should be set as second boot device.

  • network must be configured on top of rack switch which are connected to C-Series server

  • Necessary VLAN must be configured on the service facing port of that top of rack switch.

  • NOTE: You need to place PXE VLAN-untagged for any kind of OS deployment. If it’s Windows and Linux bare metal OS installation, you need to set worklaod network and you need to set Hypervisor management network for ESXi deployment.

Dell PowerConnect 7024 switches

  • The management IP address is configured for the switches.

  • ASM creates the virtual machine (VM) traffic VLANs dynamically.

  • You have access to the switches with passwords enabled..

  • Switches have SSH connectivity enabled.

Cisco Servers

  • Network and BIOS configuration cannot be done using appliance. You need to do it manually.

Dell Force10 S4810 switches (Top-of-Rack [ToR])

  • The management IP address is configured for the ToR switches.

  • Any VLAN which is dynamically provisioned by ASM must exist on the ToR switch.

  • Server facing ports must be in switchport mode.

  • Server facing ports must be configured for spanning tree portfast.

  • If DCB settings are used, it must be properly configured on the switch for converged traffic.

  • Switches have SSH connectivity enabled.

N-Series Switches

  • The management IP address is configured for the switches.

  • ASM creates the virtual machine (VM) traffic VLANs dynamically.

  • You have access to the switches with passwords enabled.

  • Switches have SSH connectivity enabled.

  • Server facing ports must be in hybrid mode.

  • Server facing ports must be in switch port mode.

  • Server facing ports must be configured for spanning tree portfast.

  • If DCB settings are used, it must be properly configured on the switch for converged traffic.

Dell PowerEdge M I/O Aggregator
  • Server facing ports must be in switchport mode.
  • Server facing ports must be configured for spanning tree portfast.
  • If ASM is used to do the initial configuration of credentials and IPs on the IOM in the blade chassis, you need to make sure, no enabled password is configured on the switches.

Dell Networking MXL 10/40GbE blade switch
  • Any VLAN which is dynamically provisioned by ASM must exist on the switch.
  • Server facing ports must be configured for spanning tree portfast.
  • Make sure DCB settings are configured on each port.
  • If ASM is used to do the initial configuration of credentials and IPs on the IOM in the blade chassis, you need to make sure, no enabled password is configured on the switches.

  • Switches have SSH connectivity enabled.

Dell 8 | 4 I/O modules

  • The management IP address is configured for the Brocade switches.

    Brocade switch should be only in Access Gateway Mode.

EqualLogic Storage Array

  • The management and group IP addresses are configured for Storage Array.

  • All storage array members are added to the group.
    • NOTE: The Equallogic management interface must be configured to enable dedicated management network.
  • EqualLogic array must have a SNMP community name set to "public".

Compellent Storage Array

  • The management IP address is configured for Storage Array

  • All storage array members are added to the group.

  • Virtual ports must be enabled on compellent.

  • Follow Compellent best-practices for storage configuration.

  • Storage Centers needs to be added to the Enterprise Manager before initiating the Element Manager discovery in ASM

  • Fault Domain and IP Address configuration of iSCSI controllers needs to be done before discovery Element Manager in ASM

  • Discovery of EM needs to be done with same credentials which are used for add storage center in Element Manager

Compellent iSCSI on MXL with Hyper V

  • Enable LLDP and its corresponding attributes

  • DCB (with no PFC option) on the participating interfaces (Server Facing and Port-Channel Members). Since DCB is globally enabled, the PFC should be turned off individually in those interface

  • Link Level Flow control (LLFC) must be Rx ON and Tx OFF on the respective interfaces

  • MTU must be set to 12000 on respective interfaces

Sample server facing interface configuration

FTOSA1#show running-config interface tengigabitethernet 0/15

!

interface TenGigabitEthernet 0/15

no ip address

mtu 12000

portmode hybrid

switchport

flowcontrol rx on tx off

spanning-tree 0 portfast

spanning-tree pvst edge-port

dcb-map DCB_MAP_PFC_OFF

!

protocol lldp

advertise management-tlv management-address system-name

dcbx port-role auto-downstream

no shutdown

Sample port-channel member interface configuration

FTOSA1#show running-config interface tengigabitethernet 0/

!

interface TenGigabitEthernet 0/41

no ip address

mtu 12000

dcb-map DCB_MAP_PFC_OFF

!

port-channel-protocol LACP

port-channel 1 mode active

!

protocol lldp

advertise management-tlv management-address system-name

no advertise dcbx-tlv ets-reco

dcbx port-role auto-upstream

no shutdown

FTOSA1#

VMware vCenter 5.1, 5.5 or 6.0

  • VMware vCenter 5.1, 5.5 or 6.0 is configured and accessible through the management and hypervisor management network.

  • Appropriate licenses are deployed on the VMware vCenter.

System Center Virtual Machine Manager (SCVMM)

PXE Setup

  • Either use Active System Manager as the PXE responder by configuring through ASM user interface, by Getting Started page or follow instructions in Configuring ASM Virtual Appliance as PXE Responder.

Dell PowerEdge M1000e chassis

  • Server facing ports must be in hybrid mode.
  • Server facing ports must be in switchport mode.

    • NOTE: Prior to deployment of M1000e server, you need to disable FlexAddress every server in the chassis.

      To disable FlexAddress, follow the path:CMC > Server Overview > Setup > FlexAddress.

      You need to turn off server to disable FlexAddress. Ideally this should be done prior discovering the server.

      This setting applies to the chassis and the servers in the chassis, not to the IOM switches such as MXL or IOA.

  • Server facing ports must be configured for spanning tree portfast.

Dell PowerEdge FX2 chassis

  • Server facing ports must be in hybrid mode.
  • Server facing ports must be in switchport mode.

    • NOTE: Prior to deployment of FX2 server, you need to disable FlexAddress every server in the chassis.

      To disable FlexAddress, follow the path:CMC > Server Overview > Setup > FlexAddress.

      You need to turn off server to disable FlexAddress. Ideally this should be done prior discovering the server.

      This setting applies to the chassis and the servers in the chassis, not to the IOM switches such as MXL or IOA.

  • Server facing ports must be configured for spanning tree portfast.

Configuration pre-requisites for S5000 FCoE

S5000 FCoE pre-requisites

Use FTOS Version – 9.8

Configure an FCoE map Applied on the Downstream (Server-Facing) Ethernet and Upstream (Core-Facing) FC Ports. Assuming FCoE VLAN is 1002 the same command needs to be executed on both FCoE Switches.

Dell(config)# fcoe-map SAN_FABRIC_A

Dell(config-fcoe-name)# fabric-id 1002 vlan 1002

Dell(config-fcoe-name)# description "SAN_FABRIC_A"

Dell(config-fcoe-name)# fc-map 0efc00

Dell(config-fcoe-name)# keepalive

Dell(config-fcoe-name)# fcf-priority 128

Dell(config-fcoe-name)# fka-adv-period 8


Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"