Active System Manager Release 8.1.1 Installation Guide

PDF

Prerequisites for M1000e (with MXL), S5000, Brocade, and Compellent

The following table describes the prerequisites for the FCoE solution offered using M1000e (with MXL), S5000, Brocade, and Compellent. For more information, see http://en.community.dell.com/techcenter/extras/m/white_papers/20387203

Resource Prerequisites
MXL
  • DCB needs to be enabled.

  • VLT needs to be disabled.

  • Switches have SSH connectivity enabled.
  • FIP Snooping feature needs to be enabled on the MXL.

    conf
                                                          Feature fip-snooping
                                                       
  • Port-channel member interfaces needs to have below configuration.

    interface range tengigabitethernet 0/33 – 36
                                                          port-channel-protocol lacp
                                                          port-channel 128 mode active
                                                          exit
                                                          protocol lldp
                                                          no advertise dcbx-tlv ets-reco
                                                          dcbx port-role auto-upstream
                                                          no shut
                                                          exit
                                                       
  • Port-channel connecting S5000 switch needs to have following configuration.

    interface port-channel 128
                                                          portmode hybrid 
                                                          switchport
                                                          fip-snooping port-mode fcf
                                                          
                                                       
  • Server facing ports needs to below configuration

    portmode hybrid
                                                          switchport
                                                          protocol lldp
                                                          dcbx port-role auto-downstream
                                                          no shut
                                                          exit
                                                       
S5000

Below configuration is prerequisite for S5000.

  • Enable Fibre Channel capability and Full Fabric mode. Switches have SSH connectivity enabled.

    feature fc
  • Enable FC ports connecting to Compellent storage array and FC ports connecting to other S5000 switch via ISL links.

    interface range fi 0/0 - 7
                                                          no shut
                                                       
  • Create DCB Map

    dcb-map SAN_DCB_MAP
                                                          priority-group 0 bandwidth 60 pfc off
                                                          priority-group 1 bandwidth 40 pfc on
                                                          priority-pgid 0 0 0 1 0 0 0 0
                                                          exit
                                                       
  • Create a FCoE VLAN

    interface vlan <VLAN ID> [Create VLAN for FCoE]
                                                          exit
                                                       
  • Create FCoE Map

    fcoe-map default_full_fabric
                                                          fabric-id <FCoE VLAN ID> vlan <FCoE VLAN Id>
                                                          fc-map <FC MAP>
                                                          exit
                                                       
  • Apply FCoE MAP to interface

    interface fibrechannel 0/0
                                                          fabric default_full_fabric
                                                          no shutdown
                                                       
    • NOTE: Below is the process of generating the FC MAP

    For generating the fc-map use below ruby code.

    Here VLAN ID is FCoE VLAN ID

    fc_map = vlanid.to_i.to_s(16).upcase[0..1]
                                                          fc_map.length == 1 ? fc_map = "0EFC0
                                                          #{fc_map
                                                          }" : fc_map =
                                                          "0EFC
                                                          #{fc_map
                                                          }"
                                                       
Brocade

Alias needs to be created having Compellent fault domain WWPN accessible on Brocade switch.

Compellent

Nothing specific for ASM


Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"