Table below documents valid options and arguments along with a description of the expected behavior of each option. Options and arguments are case sensitive. All options and pre-defined arguments are lowercase unless stated otherwise.
  • NOTE: Some of the following options or arguments might not be available on all systems. Some of the command line options are followed by an asterisk. Such options are used for reporting purposes only
Table 1. SYSCFG Options and Arguments for System Configuration
Option Valid Arguments Description
--asset None

Reports the customer-programmable asset tag number for a system. This option displays the asset tag for a system. For Blade systems, the SYSCFG utility reports the asset tag for both the server module and the asset tag for its chassis. For more information on delimiters, see Command Line Option Delimiters .

Example:

A:>syscfg --asset
asset=ASSET
--biosver* None

Reports the BIOS version for a system. If used with the -s option, the environment variable is set to the BIOS version.

Example:

A:>syscfg --biosver
biosver=A08
--chassvctag* None

Reports the chassis service tag on blade systems.

Example:

A:>syscfg --chassvctag
chassvctag=SVCTAG1
--cpucount* None

Reports the number of processors found on the system.

Example 1:

A:>syscfg --cpucount cpucount=1

Example 2:

A:>syscfg --cpucount cpucount=2
--cpuspeed* None

Reports the speed of all processors in a system.

Example:

A:>syscfg --cpuspeed
cpuspeed=1000MHz
--envfile < filename>

Reads the environment variable file (included in DTK as sys.ini ) and sets environment variables to names in the file, based on the system's information. Primarily, this command performs a PCI scan and matches the vendor/device numbers of the devices to those specified in the environment variable file. For more information, see the Environment Variable File .

Example:

A:>syscfg --envfile sys.ini
DELLNIC1=INTEL PRO100
                                                DELLNIC2=INTEL PRO100
                                                DVIDEO1=RAGEXL
                                                DIDE1=PEQUR/ROSS IDE
                                                DSCSI1=AIC-7899
                                             
--mem* None

Reports the amount of system memory physically installed in the system, not the amount of memory available to an operating system. If used with the -s option, the environment variable is set to the amount of system memory. The last two characters of the memory value indicate the order of magnitude used (KB or MB).

Example:

A:>syscfg --mem
mem=256MB
-n < filename>

Specifies an input file to use for resolving PCI vendor and device numbers to strings. The file must be present (with read rights) and contain a properly formatted list. For more information, see PCI Reporting . This option must be used with the pci option.

Example:

A:>syscfg -n pci.txt --pci
PCI Bus: 2, Device: 4, Function: 0
                                                Vendor: 8086 - Intel Corp.
                                                Device: 1229 - 82557/8/9 [Ethernet Pro 100]
                                                Sub Vendor:8086 - Intel Corp.
                                                Sub Device:1017 - EtherExpress
                                             
PRO/100+ Dual Port Server Adapter
                                                Slot: 01
                                                Class: 02 - Network
                                                SubClass: 00 - Ethernet
                                             
--ovrwrt* None
When used with the outfile option, this option specifies that the output file should be overwritten if it exists.
  • NOTE: This option is applicable only on PowerEdge systems prior to 12G.

Example:

A:>syscfg -outfile=out.ini --ovrwrt
--pci* None

Performs a scan of all PCI buses and displays the results. The utility uses an open source pci.ids file for vendor/device name resolution. The utility looks for a file called pci.ids in the current working directory. If the file is not found in the current working directory, the directory containing the SYSCFG executable is searched. If the -n option is used to specify a filename, this filename is used for resolution. If a specific filename is not given and the pci.ids file cannot be found, Unknown is printed for all vendor and device codes.

For more information, see PCI Reporting.

Example 1 (the pci.ids filename is specified in the command line instance ):

A:>syscfg -n pci.ids --pci
PCI Bus: 0, Device: 0, Function: 0
                                                Vendor: 1166 - ServerWorks
                                                Device: 0012 - CMIC-LE
                                                Slot: 00
                                                Class: 06 - Bridge
                                                SubClass: 00 - CPU/PCI
                                             
PCI Bus: 0, Device: 0, Function: 1
                                                Vendor: 1166 - ServerWorks
                                                Device: 0012 - CMIC-LE
                                                Slot: 00
                                                Class: 06 - Bridge
                                                SubClass: 00 - CPU/PCI
                                             
PCI Bus: 0, Device: 0, Function: 2
                                                Vendor: 1166 - ServerWorks
                                                Device: 0000 - Unknown
                                                Slot: 00
                                                Class: 06 - Bridge
                                                SubClass: 00 - CPU/PCI
                                             
  None

Example 2 (the pci.ids file is located in the same directory as the utility so that names resolve):

A:>syscfg --pci
PCI Bus: 0, Device: 0, Function: 0
                                                Vendor: 1166 - ServerWorks
                                                Device: 0012 - CMIC-LE
                                                Slot: 00
                                                Class: 06 - Bridge
                                                SubClass: 00 - CPU/PCI
                                             
PCI Bus: 0, Device: 0, Function: 1
                                                Vendor: 1166 - ServerWorks
                                                Device: 0012 - CMIC-LE
                                                Slot: 00
                                                Class: 06 - Bridge
                                                SubClass: 00 - CPU/PCI
                                             
PCI Bus: 0, Device: 0, Function: 2
                                                Vendor: 1166 - ServerWorks
                                                Device: 0000 - Unknown
                                                Slot: 00
                                                Class: 06 - Bridge
                                                SubClass: 00 - CPU/PCI
                                             
  None

Example 3 (a pci.ids file does not exist) :

A:>syscfg --pci
PCI Bus: 0, Device: 0, Function: 0
                                                Vendor: 1166 - Unknown
                                                Device: 0012 - Unknown
                                                Slot: 00
                                                Class: 06 - Bridge
                                                SubClass: 00 - CPU/PCI
                                             
PCI Bus: 0, Device: 0, Function: 1
                                                Vendor: 1166 - Unknown
                                                Device: 0012 - Unknown
                                                Slot: 00
                                                Class: 06 - Bridge
                                                SubClass: 00 - CPU/PCI
                                             
PCI Bus: 0, Device: 0, Function: 2
                                                Vendor: 1166 - Unknown
                                                Device: 0000 - Unknown
                                                Slot: 00
                                                Class: 06 - Bridge
                                                SubClass: 00 - CPU/PCI
                                             
-s < string>

Sets an environment variable to the value of a function command option. The string argument must be alphanumeric without any spaces or symbols. The variable name must be in upper case. This option must be used with at least one function command.

Example:

A:>syscfg -s ENVNAME --svctag
ENVNAME=SERVICE
--slot* None

Reports the slot on a Blade system. If it is not a Blade system, the slot is reported as 0. If used with the -s option, the environment variable is set to the slot.

Example 1 (Blade systems) :

A:>syscfg --slot
slot=1

Example 2 (Rack and Tower systems) :

A:>syscfg --slot
slot=0
  • NOTE: This option is valid only on PowerEdge blade systems.
--svctag* None

Reports the service tag for a system. If used with the -s option, the environment variable is set to the BIOS version.

Example:

A:>syscfg --svctag
svctag=113CD1S
--sysasset* None

Reports the system asset tag on Blade systems.

Example:

A:>syscfg --sysasset
sysasset=ASSET01
--sysid* None

Reports the unique system id bytes for a server. Servers contain a unique ID value based on their model. The ID value is reported as a hexadecimal value with a leading 0x, lowercase hexadecimal letters, and zero-padded to 2 bytes. If used with the -s general option, the environment variable is set to the system ID.

Example:

A:>syscfg --sysid
sysid=0x00df
--sysname* None

Reports the system identification string for a server, which is the string displayed under the Dell logo during POST. If used with the -s option, the environment variable is set to the system name.

Example:

A:>syscfg --sysname
sysname=PowerEdge 1550/1000
--syssvctag* None

Reports the system service tag on a Blade system.

Example:

A:>syscfg --syssvctag
syssvctag=BLADE01
--uuid* None

Reports the Unique User Identifier (UUID) for a system. The UUID is a unique system identifier used in PXE requests.

Example:

A:>syscfg --uuid
uuid=44454C4C-5300-104C-8044- B1C04F423131

Оценить этот контент

Точно
Функционально
Просто понять
Помогла ли вам эта статья?
0/3000 characters
  Поставьте оценку (1–5 звезд).
  Поставьте оценку (1–5 звезд).
  Поставьте оценку (1–5 звезд).
  Выберите ответ на вопрос, была ли статья полезной.
  Комментарии не должны содержать следующие специальные символы: <>()\