Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

iDRAC 8/7 v2.30.30.30 User’s Guide

Switching the controller mode using RACADM

To switch the controller mode using RACADM, run the following commands:
  • To view the current mode of the controller, at the RACADM prompt, run the $ racadm get Storage.Controller.1.RequestedControllerMode[key=<Controller_FQDD>] command. The following output is displayed: RequestedControllerMode = NONE .
  • To set the controller mode as HBA, run the $ racadm set Storage.Controller.1.RequestedControllerMode HBA [Key=< Controller_FQDD >] command.

For more information about the RACADM commands, see the iDRAC8 RACADM Command Line Interface Reference Guide available at dell.com/idracmanuals.


Rate this content

Accurate
Useful
Easy to understand
Was this article helpful?
0/3000 characters
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please provide ratings (1-5 stars).
  Please select whether the article was helpful or not.
  Comments cannot contain these special characters: <>()\