Skip to main content
  • Place orders quickly and easily
  • View orders and track your shipping status
  • Enjoy members-only rewards and discounts
  • Create and access a list of your products
  • Manage your Dell EMC sites, products, and product-level contacts using Company Administration.

iDRAC 8/7 v2.50.50.50 User’s Guide

Configuring iDRAC to use SOL using RACADM

To configure IPMI Serial over LAN (SOL):
  1. Enable IPMI Serial over LAN using the command.
    racadm set iDRAC.IPMISol.Enable 1
  2. Update the IPMI SOL minimum privilege level using the command.
    racadm set iDRAC.IPMISol.MinPrivilege <level>
    ParameterPrivilege level
    <level> = 2 User
    <level> = 3 Operator
    <level> = 4 Administrator
    NOTE: The IPMI SOL minimum privilege level determines the minimum privilege to activate IPMI SOL. For more information, see the IPMI 2.0 specification.
  3. Update the IPMI SOL baud rate using the command.
    racadm set iDRAC.IPMISol.BaudRate <baud_rate>
    NOTE: To redirect the serial console over LAN, make sure that the SOL baud rate is identical to the managed system’s baud rate.
    ParameterAllowed values (in bps)
    <baud_rate> 9600, 19200, 38400, 57600, and 115200.
  4. Enable SOL for each user using the command.
    racadm set iDRAC.Users.<id>.SolEnable 2
    ParameterDescription
    <id> Unique ID of the user
NOTE: To redirect the serial console over LAN, ensure that the SOL baud rate is identical to the baud rate of the managed system.