iDRAC 8/7 v2.50.50.50 User’s Guide

Updating CMC firmware from iDRAC

In the PowerEdge FX2/FX2s chassis, you can update the firmware for the Chassis Management Controller and any component that can be updated by CMC and shared by the servers from iDRAC.

Before applying the update, make sure that:
  • Servers are not allowed to power-up by CMC.
  • Chassis with LCD must display a message indicating “update is in-progress”.
  • Chassis without LCD must indicate the update progress using LED blinking pattern.
  • During the update, chassis action power commands are disabled.

The updates for components such as Programmable System-on-Chip (PSoC) of IOM that requires all the servers to be idle, the update is applied on the next chassis power-up cycle.