OpenManage Integration for VMware vCenter Version 5.0 User's Guide

Virtualization-related events

The following table contains the virtualization-related critical and warning events, and includes event name, description, severity level, and recommended action.

The vitalization-related events are displayed in the following format:

Dell-Message ID:<ID number>, Message:<Message Description>.

The chassis events are displayed in the following format:

Dell-Message:<Message description>, Chassis name:<name of the chassis>, Chassis Service Tag:<chassis Service Tag >, Chassis Location:<chassis location>

Table 1. Virtualization eventsThe following table provides the virtualization-related events for 11th, 12th, and 13th generation of PowerEdge servers.
Event name Description Severity Recommended action
Dell-Current sensor detected a warning value A current sensor in the specified system exceeded its warning threshold Warning No action
Dell-Current sensor detected a failure value A current sensor in the specified system exceeded its failure threshold Error Put the system into maintenance mode
Dell-Current sensor detected a non-recoverable value A current sensor in the specified system detected an error from which it cannot recover Error No action
Dell-Redundancy regained Sensor Returned to Normal Value Info No action
Dell-Redundancy degraded A redundancy sensor in the specified system detected that one of the components of the redundancy unit has failed but the unit is still redundant Warning No action
Dell-Redundancy lost A redundancy sensor in the specified system detected that one of the components in the redundant unit has been disconnected, has failed, or is not present Error Put the system into maintenance mode
Dell-Power supply returned to normal Sensor returned to Normal Value Info No action
Dell-Power supply detected a warning A power supply sensor reading in the specified system exceeded a user definable warning threshold Warning No action
Dell-Power supply detected a failure A power supply has been disconnected or has failed Error Put the system into maintenance mode
Dell-Power supply sensor detected a non-recoverable value A power supply sensor in the specified system detected an error from which it cannot recover Error No action
Dell-Memory Device Status warning A memory device correction rate exceeded an acceptable value Warning No action
Dell-Memory Device error A memory device correction rate exceeded an acceptable value, a memory spare bank was activated, or a multibit ECC error occurred Error Put the system into maintenance mode
Dell-Fan enclosure inserted into system Sensor returned to normal value Info No action
Dell-Fan enclosure removed from system A fan enclosure has been removed from the specified system Warning No action
Dell-Fan enclosure removed from system for an extended amount of time A fan enclosure has been removed from the specified system for a user-definable length of time Error No action
Dell-Fan enclosure sensor detected a non-recoverable value A fan enclosure sensor in the specified system detected an error from which it cannot recover Error No action
Dell-AC power has been restored Sensor Returned to Normal Value Info No action
Dell-AC power has been lost warning An AC power cord has lost its power, but there is sufficient redundancy to classify this as a warning Warning No action
Dell-An AC power cord has lost its power An AC power cord has lost its power, and lack of redundancy requires this to be classified as an error Error No action
Dell-Processor sensor returned to a normal value Sensor Returned to Normal Value Info No action
Dell-Processor sensor detected a warning value A processor sensor in the specified system is in a throttled state Warning No action
Dell-Processor sensor detected a failure value A processor sensor in the specified system is disabled, has a configuration error, or experienced a thermal trip Error No action
Dell-Processor sensor detected a non-recoverable value A processor sensor in the specified system has failed. Error No action
Dell-Device configuration error A configuration error was detected for a pluggable device in the specified system Error No action
Dell-Battery sensor returned to a normal value Sensor Returned to Normal Value Info No action
Dell-Battery sensor detected a warning value A battery sensor in the specified system detected that a battery is in a predictive failure state Warning No action
Dell-Battery sensor detected a failure value A battery sensor in the specified system detected that a battery has failed Error No action
Dell-Battery sensor detected a nonrecoverable value A battery sensor in the specified system detected that a battery has failed Error No Action
Dell-Thermal shutdown protection has been initiated This message is generated when a system is configured for thermal shutdown due to an error event. If a temperature sensor reading exceeds the error threshold for which the system is configured, the operating system shuts down and the system powers off. This event may also be initiated on certain systems when a fan enclosure is removed from the system for an extended period of time Error No action
Dell-Temperature sensor returned to a normal value Sensor Returned to Normal Value Info No action
Dell-Temperature sensor detected a warning value A temperature sensor on the backplane board, system board, CPU, or drive carrier in the specified system exceeded its warning threshold Warning No action
Dell-Temperature sensor detected a failure value A temperature sensor on the backplane board, system board, or drive carrier in the specified system exceeded its failure threshold value Error Put the system into maintenance mode
Dell-Temperature sensor detected a non-recoverable value A temperature sensor on the backplane board, system board, or drive carrier in the specified system detected an error from which it cannot recover Error No action
Dell-Fan sensor returned to a normal value Sensor Returned to Normal Value Info No action
Dell-Fan sensor detected a warning value Fan Sensor reading in the host <x> exceeded a warning threshold value Warning No Action
Dell-Fan sensor detected a failure value A fan sensor in the specified system detected the failure of one or more fans Error Put the system into maintenance mode
Dell-Fan sensor detected a nonrecoverable value A fan sensor detected an error from which it cannot recover Error No action
Dell-Voltage sensor returned to a normal value Sensor Returned to Normal Value Info No action
Dell-Voltage sensor detected a warning value A voltage sensor in the specified system exceeded its warning threshold Warning No action
Dell-Voltage sensor detected a failure value A voltage sensor in the specified system exceeded its failure threshold Error Put the system into maintenance mode
Dell-Voltage sensor detected a nonrecoverable value A voltage sensor in the specified system detected an error from which it cannot recover Error No action
Dell-Current sensor returned to a normal value Sensor Returned to Normal Value Info No action
Dell-Storage: storage management error Storage management has detected a device independent error condition Error Put the system into maintenance mode
Dell-Storage: Controller warning A portion of the physical disk is damaged Warning No action
Dell-Storage: Controller failure A portion of the physical disk is damaged Error Put the system into maintenance mode
Dell-Storage: Channel Failure Channel failure Error Put the system into maintenance mode
Dell-Storage: Enclosure hardware information Enclosure hardware information Info No action
Dell-Storage: Enclosure hardware warning Enclosure hardware warning Warning No action
Dell-Storage: Enclosure hardware failure Enclosure hardware error Error Put the system into maintenance mode
Dell-Storage: Array disk failure Array disk failure Error Put the system into maintenance mode
Dell-Storage: EMM failure EMM failure Error Put the system into maintenance mode
Dell-Storage: power supply failure Power supply failure Error Put the system into maintenance mode
Dell-Storage: temperature probe warning Physical disk temperature probe warning, too cold or too hot Warning No action
Dell-Storage: temperature probe failure Physical disk temperature probe error, too cold or too hot. Error Put the system into maintenance mode
Dell-Storage: Fan failure Fan failure Error Put the system into maintenance mode
Dell-Storage: Battery warning Battery warning Warning No action
Dell-Storage: Virtual disk degraded warning Virtual disk degraded warning Warning No action
Dell-Storage: Virtual disk degraded failure Virtual disk degraded failure Error Put the system into maintenance mode
Dell-Storage: Temperature probe information Temperature probe information Info No action
Dell-Storage: Array disk warning Array disk warning Warning No action
Dell-Storage: Array disk information Array disk information Info No action
Dell-Storage: Power supply warning Power supply warning Warning No action
Dell-Fluid Cache Disk failure Fluid cache disk failure Error Put the system into maintenance mode
Dell-Cable failure or critical event Cable failure or critical event Error Put the system into maintenance mode
Dell-Chassis Management Controller detected a warning Chassis Management Controller detected a warning Warning No action
Dell-Chassis Management Controller detected an error Chassis Management Controller detected an error Error Put the system into maintenance mode
Dell-IO Virtualization failure or critical event IO virtualization failure or critical event Error Put the system into maintenance mode
Dell-Link status warning Link status warning Warning No action
Dell-Link status failure or critical event Link status failure or critical event Error Put the system into maintenance mode
Dell-Security warning Security warning Warning No action
Dell-System: Software configuration warning System: Software configuration warning Warning No action
Dell-System: Software configuration failure System: Software configuration failure Error Put the system into maintenance mode
Dell-Storage Security warning Storage security warning Warning No action
Dell-Storage Security failure or critical event Storage security failure or critical event Error Put the system into maintenance mode
Dell-Software change update warning Software change update warning Warning No action
Dell-Chassis Management Controller audit warning Chassis Management Controller audit warning Warning No action
Dell-Chassis Management Controller audit failure or critical event Chassis Management Controller audit failure or critical event Error Put the system into maintenance mode
Dell-PCI device audit warning PCI device audit warning Warning No action
Dell Power Supply audit warning Power supply audit warning Warning No action
Dell-Power Supply audit failure or critical event Power supply audit failure or critical event Error Put the system into maintenance mode
Dell-Power usage audit warning Power usage audit warning Warning No action
Dell-Power usage audit failure or critical event Power usage audit failure or critical event Error Put the system into maintenance mode
Dell-Security configuration warning Security configuration warning Warning No action
Dell-Configuration: Software configuration warning Configuration: Software configuration warning Warning No action
Dell-Configuration: Software configuration failure Configuration: Software configuration failure Error Put the system into maintenance mode
Dell-Virtual Disk Partition failure Virtual disk partition failure Error Put the system into maintenance mode
Dell-Virtual Disk Partition warning Virtual disk partition warning Warning No action
iDRAC events
NOTE For all Proactive HA enabled hosts that are part of a cluster, the following virtualization events are mapped to the Proactive HA events; except events, "The fans are not redundant" and "The power supplies are not redundant" are not mapped.
The fans are redundant None Info No action
Fan redundancy is lost One of more fans have failed or have been removed or a configuration change occurred, which requires additional fans Critical Remove and reinstall failed fans or install additional fans
Fan redundancy is degraded One of more fans have failed or have been removed or a configuration change occurred, which requires additional fans. Warning Remove and reinstall failed fans or install additional fans
The fans are not redundantOne of more fans have failed or have been removed or a configuration change occurred, which requires additional fansInfoRemove and reinstall failed fans or install additional fans
The fans are not redundant. Insufficient resources to maintain normal operationsOne of more fans have failed or have been removed or a configuration change occurred, which requires additional fansCriticalRemove and reinstall failed fans or install additional fans
The power supplies are redundantNoneInfoNo action
Power supply redundancy is lostThe current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant modeCriticalCheck the event log for power supply failures. Review system configuration and power consumption
Power supply redundancy is degradedThe current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant modeWarningCheck the event log for power supply failures. Review system configuration and power consumption
The power supplies are not redundantThe current power supply configuration does not meet the platform requirements to enable redundancy. If a power supply fails the system may shut down.InfoIf unintended, review system configuration and power consumption and install power supplies accordingly. Check power supply status for failures
The power supplies are not redundant. Insufficient resources to maintain normal operationsThe system may power down or operate in a performance degraded stateCriticalCheck the event log for power supply failures. Review system configuration and power consumption and upgrade or install power supplies accordingly
Internal Dual SD Module is redundantNoneInfoNo action
Internal Dual SD Module redundancy is lostEither one of the SD card or both the SD cards are not functioning properlyCriticalReplace the failed SD card
Internal Dual SD Module redundancy is degradedEither one of the SD card or both the SD cards are not functioning properlyWarningReplace the failed SD card
Internal Dual SD Module is not redundantNoneInfoInstall additional SD card and configure for redundancy if redundancy is desired
Chassis events
Power supply redundancy is lostThe current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant modeCriticalCheck the event log for power supply failures. Review system configuration and power consumption
Power supply redundancy is degradedThe current power operational mode is non-redundant because of a power supply exception, a power supply inventory change, or a system power inventory change. The system was previously operating in a power redundant modeWarningCheck the event log for power supply failures. Review system configuration and power consumption
The power supplies are redundantNoneInfoNo action
The power supplies are not redundantThe current power supply configuration does not meet the platform requirements to enable redundancy. If a power supply fails the system may shut down.InfoIf unintended, review system configuration and power consumption and install power supplies accordingly. Check power supply status for failures
The power supplies are not redundant. Insufficient resources to maintain normal operationsThe system may power down or operate in a performance degraded stateCriticalCheck the event log for power supply failures. Review system configuration and power consumption and upgrade or install power supplies accordingly
Fan redundancy is lostOne of more fans have failed or have been removed or a configuration change occurred, which requires additional fansCriticalRemove and reinstall failed fans or install additional fans
Fan redundancy is degradedOne of more fans have failed or have been removed or a configuration change occurred, which requires additional fans.WarningRemove and reinstall failed fans or install additional fans
The fans are redundantNoneInfoNo action
The fans are not redundantOne of more fans have failed or have been removed or a configuration change occurred, which requires additional fansInfoRemove and reinstall failed fans or install additional fans
The fans are not redundant. Insufficient resources to maintain normal operationsOne of more fans have failed or have been removed or a configuration change occurred, which requires additional fansCriticalRemove and reinstall failed fans or install additional fans