Dell PowerEdge RAID Controller 9 User’s Guide H330, H730, and H830

Virtual disks partially degraded error message

Error Message:
x Virtual Disk(s) Partially Degraded, where x is the number of virtual disks partially degraded.
Probable Cause:
This message is displayed when the BIOS detects a single disk failure in a RAID 6 or RAID 60 configuration.
Corrective Action:
You must check why the member disk is not present to correct the problem. The BIOS does not take any action.