Chassis Management Controller Version 2.0 for Dell PowerEdge VRTX User's Guide

Show Table of Contents

  • Notes, Cautions, and Warnings

  • Overview
    • What Is New In This Release
    • Key Features
      • Management Features
      • Security Features
    • Chassis Overview
    • Minimum CMC Version
    • Supported Remote Access Connections
    • Supported Platforms
    • Supported Web Browsers
    • Managing Licenses
      • Types of Licenses
      • Acquiring Licenses
      • License Operations
      • License Component State or Condition and Available Operations
      • Managing Licenses Using CMC Web Interface
      • Managing Licenses Using RACADM
      • Licensable Features in CMC
    • Viewing Localized Versions of the CMC Web Interface
    • Supported Management Console Applications
    • How to Use this User's Guide
    • Other Documents You May Need
    • Accessing documents from Dell support site

  • Installing and Setting Up CMC
    • Before You Begin
    • Installing CMC Hardware
      • Checklist To Set up Chassis
      • Basic CMC Network Connection
    • Installing Remote Access Software on a Management Station
      • Installing RACADM on a Linux Management Station
      • Uninstalling RACADM From a Linux Management Station
    • Configuring a Web Browser
      • Proxy Server
        • Internet Explorer
        • Mozilla FireFox
      • Microsoft Phishing Filter
      • Certificate Revocation List (CRL) Fetching
      • Downloading Files From CMC With Internet Explorer
      • Enabling Animations In Internet Explorer
    • Setting Up Initial Access to CMC
      • Configuring Initial CMC Network
        • Configuring CMC Network Using LCD Panel Interface
    • Interfaces and Protocols to Access CMC
      • Launching CMC Using Other Systems Management Tools
    • Downloading and Updating CMC Firmware
    • Setting Chassis Physical Location and Chassis Name
      • Setting Chassis Physical Location and Chassis Name Using Web Interface
      • Setting Chassis Physical Location and Chassis Name Using RACADM
    • Setting Date and Time on CMC
      • Setting Date and Time on CMC Using CMC Web Interface
      • Setting Date and Time on CMC Using RACADM
    • Configuring LEDs to Identify Components on the Chassis
      • Configuring LED Blinking Using CMC Web Interface
      • Configuring LED Blinking Using RACADM
    • Configuring CMC Properties
    • Configuring iDRAC Launch Method Using CMC Web Interface
    • Configuring iDRAC Launch Method Using RACADM
    • Configuring Login Lockout Policy Attributes Using CMC Web Interface
    • Configuring Login Lockout Policy Attributes Using RACADM
    • Understanding Redundant CMC Environment
      • About Standby CMC
      • CMC Failsafe Mode
      • Active CMC Election Process
      • Obtaining Health Status of Redundant CMC
    • Configuring Front Panel
      • Configuring Power Button
      • Configuring LCD
      • Accessing a Server Using KVM
        • Mapping a Server to KVM Using CMC Web Interface
        • Mapping the Server to KVM Using LCD
        • Mapping a Server to a DVD Drive

  • Logging in to CMC
    • Accessing CMC Web Interface
    • Logging in to CMC as a Local User, Active Directory User, or LDAP User
    • Logging in to CMC Using a Smart Card
    • Logging in to CMC Using Single Sign-on
    • Logging In To CMC Using Serial, Telnet, Or SSH Console
    • Accessing CMC Using RACADM
    • Logging in to CMC Using Public Key Authentication
    • Multiple CMC Sessions
    • Changing Default Login Password
      • Changing Default Login Password Using Web Interface
      • Changing Default Login Password Using RACADM
    • Enabling or Disabling Default Password Warning Message
      • Enabling or Disabling Default Password Warning Message Using Web Interface
      • Enabling or Disabling Warning Message to Change Default Login Password Using RACADM

  • Updating Firmware
    • Downloading CMC Firmware
    • Viewing Currently Installed Firmware Versions
      • Viewing Currently Installed Firmware Versions Using CMC Web Interface
      • Viewing Currently Installed Firmware Versions Using RACADM
    • Updating the CMC Firmware
      • Signed CMC Firmware Image
      • Updating CMC Firmware Using Web Interface
      • Updating CMC Firmware Using RACADM
    • Updating Chassis Infrastructure Firmware
      • Updating Chassis Infrastructure Firmware Using CMC Web Interface
      • Updating Chassis Infrastructure Firmware Using RACADM
    • Updating Server iDRAC Firmware
      • Updating Server iDRAC Firmware Using Web Interface
    • Updating Server Component Firmware
      • Server Component Update Sequence
      • Enabling Lifecycle Controller
      • Choosing Server Component Firmware Update Type Using CMC Web Interface
      • Filtering Components for Firmware Updates
        • Filtering Components for Firmware Updates Using CMC Web Interface
        • Filtering Components for Firmware Updates Using RACADM
    • Viewing Firmware Inventory
      • Viewing Firmware Inventory Using CMC Web Interface
      • Viewing Firmware Inventory Using RACADM
    • Saving Chassis Inventory Report Using CMC Web Interface
    • Configuring Network Share Using CMC Web Interface
    • Lifecycle Controller Job Operations
      • Reinstalling Server Component Firmware
        • Re-installing Server Component Firmware Using Web Interface
    • Rolling Back Server Component Firmware
      • Rolling Back Server Component Firmware Using the CMC Web Interface
    • Upgrading Server Component Firmware
      • Upgrading Server Component Firmware From File Using CMC Web Interface
      • Server Component Single Click Update Using Network Share
      • Pre-requisites for Using Network Share Update Mode
      • Upgrading Server Component Firmware From Network Share Using CMC Web Interface
    • Deleting Scheduled Server Component Firmware Jobs
      • Deleting Scheduled Server Component Firmware Jobs Using the Web Interface
    • Updating Storage Component Using CMC Web Interface
    • Recovering iDRAC Firmware Using CMC

  • Viewing Chassis Information and Monitoring Chassis and Component Health
    • Viewing Chassis and Component Summaries
      • Chassis Graphics
      • Selected Component Information
      • Viewing Server Model Name and Service Tag
    • Viewing Chassis Summary
    • Viewing Chassis Controller Information and Status
    • Viewing Information and Health Status of All Servers
    • Viewing Health Status and Information for Individual Server
    • Viewing Information and Health Status of the IOM
    • Viewing Information and Health Status of Fans
      • Configuring Fans
    • Viewing Front Panel Properties
    • Viewing KVM Information and Health Status
    • Viewing LCD Information and Health
    • Viewing Information and Health Status of Temperature Sensors
    • Viewing Storage Capacity and Status of the Storage Components

  • Configuring CMC
    • Viewing and Modifying CMC Network LAN Settings
      • Viewing and Modifying CMC Network LAN Settings Using CMC Web Interface
      • Viewing and Modifying CMC Network LAN Settings Using RACADM
      • Enabling the CMC Network Interface
      • Enabling or Disabling DHCP for the CMC Network Interface Address
      • Enabling or Disabling DHCP for DNS IP Addresses
      • Setting Static DNS IP addresses
      • Configuring DNS Settings (IPv4 and IPv6)
      • Configuring Auto Negotiation, Duplex Mode, and Network Speed (IPv4 and IPv6)
      • Setting the Maximum Transmission Unit (MTU) (IPv4 and IPv6)
    • Configuring CMC Network and Login Security Settings
      • Configuring IP Range Attributes Using CMC Web Interface
      • Configuring IP Range Attributes Using RACADM
    • Configuring Virtual LAN Tag Properties for CMC
      • Configuring Virtual LAN Tag Properties for CMC Using RACADM
      • Configuring Virtual LAN Tag Properties for CMC Using Web Interface
    • Configuring Services
      • Configuring Services Using CMC Web Interface
      • Configuring Services Using RACADM
    • Configuring CMC Extended Storage Card
    • Setting Up Chassis Group
      • Adding Members To Chassis Group
      • Removing a Member from the Leader
      • Disbanding a Chassis Group
      • Disabling an Individual Member at the Member Chassis
      • Accessing the Web page of a Member Chassis or Server
      • Propagating Leader Chassis Properties to Member Chassis
      • Server Inventory for MCM group
      • Saving Server Inventory Report
        • Exported Data
        • Data Format
      • Chassis Group Inventory and Firmware Version
      • Viewing Chassis Group Inventory
      • Viewing Selected Chassis Inventory Using Web Interface
      • Viewing Selected Server Component Firmware Versions Using Web Interface
    • Configuring Multiple CMCs Using RACADM
      • Creating a CMC Configuration File
      • Parsing Rules
      • Modifying the CMC IP Address
    • Viewing and Ending CMC Sessions
      • Viewing and Ending CMC Sessions Using Web Interface
      • Viewing and Ending CMC Sessions Using RACADM

  • Configuring Servers
    • Configuring Slot Names
    • Configuring iDRAC Network Settings
      • Configuring iDRAC QuickDeploy Network Settings
      • Assigning QuickDeploy IP Address to Servers
      • Modifying iDRAC Network Settings for Individual Server iDRAC
      • Modifying iDRAC Network Settings Using RACADM
    • Configuring iDRAC Virtual LAN Tag Settings
      • Configuring iDRAC Virtual LAN Tag Settings Using RACADM
      • Configuring iDRAC Virtual LAN Tag Settings Using Web Interface
    • Setting First Boot Device
      • Setting First Boot Device For Multiple Servers Using CMC Web Interface
      • Setting First Boot Device For Individual Server Using CMC Web Interface
      • Setting First Boot Device Using RACADM
    • Configuring Server FlexAddress
    • Configuring Remote File Share
    • Configuring Profile Settings Using Server Configuration Replication
      • Accessing Server Profiles Page
      • Adding or Saving Profile
      • Applying Profile
      • Importing Profile
      • Exporting Profile
      • Editing Profile
      • Deleting Profile
      • Viewing Profile Settings
      • Viewing Stored Profile Settings
      • Viewing Profile Log
      • Completion Status And Troubleshooting
      • Quick Deploy of Profiles
      • Assigning Server Profiles to Slots
      • Launching iDRAC using Single Sign-On
        • Launching iDRAC from Server Status Page
        • Launching iDRAC from Servers Status Page
      • Launching Remote Console
        • Launching Remote Console from Chassis Health Page
        • Launching Remote Console from Server Status Page
        • Launching Remote Console from Servers Status Page

  • Configuring CMC To Send Alerts
    • Enabling Or Disabling Alerts
      • Enabling Or Disabling Alerts Using CMC Web Interface
      • Filtering Alerts
        • Filtering Alerts Using CMC Web Interface
        • Setting Event Alerts Using RACADM
    • Configuring Alert Destinations
      • Configuring SNMP Trap Alert Destinations
        • Configuring SNMP Trap Alert Destinations Using CMC Web Interface
        • Configuring SNMP Trap Alert Destinations Using RACADM
      • Configuring Email Alert Settings
        • Configuring Email Alert Settings Using CMC Web Interface
        • Configuring EMail Alert Settings Using RACADM

  • Configuring User Accounts and Privileges
    • Types of Users
    • Modifying Root User Administrator Account Settings
    • Configuring Local Users
      • Configuring Local Users Using CMC Web Interface
      • Configure Local Users Using RACADM
        • Adding CMC User Using RACADM
        • Disabling CMC User
        • Enabling CMC User With Permissions
    • Configuring Active Directory Users
      • Supported Active Directory Authentication Mechanisms
      • Standard Schema Active Directory Overview
      • Configuring Standard Schema Active Directory
        • Configuring Active Directory With Standard Schema Using CMC Web Interface
        • Configuring Active Directory With Standard Schema Using RACADM
      • Extended Schema Active Directory Overview
        • Active Directory Schema Extensions
        • Overview of Schema Extensions
      • Configuring Extended Schema Active Directory
        • Extending Active Directory Schema
          • Using Dell Schema Extender
            • Classes And Attributes
        • Installing Dell Extension to the Active Directory Users and Computers Snap-In
        • Adding CMC Users And Privileges To Active Directory
          • Creating RAC Device Object
          • Creating Privilege Object
          • Creating Association Object
          • Adding Objects To Association Object
          • Adding Users Or User Groups
          • Adding Privileges
          • Adding RAC Devices Or RAC Device Groups
        • Configuring Active Directory With Extended Schema Using CMC Web Interface
        • Configuring Active Directory With Extended Schema Using RACADM
    • Configuring Generic LDAP Users
      • Configuring the Generic LDAP Directory to Access CMC
        • Authentication of LDAP Users
        • Authorization Of LDAP Users
      • Configuring Generic LDAP Directory Service Using CMC Web Interface
      • Configuring Generic LDAP Directory Service Using RACADM

  • Configuring CMC For Single Sign-On Or Smart Card Login
    • System Requirements
      • Client Systems
      • CMC
    • Prerequisites For Single Sign-On Or Smart Card Login
    • Generating Kerberos Keytab File
    • Configuring CMC For Active Directory Schema
    • Configuring Browser For SSO Login
      • Internet Explorer
      • Mozilla Firefox
    • Configuring Browser For Smart Card Login
    • Configuring CMC SSO Or Smart Card Login For Active Directory Users
      • Configuring CMC SSO Or Smart Card Login For Active Directory Users Using Web Interface
      • Uploading Keytab File
      • Configuring CMC SSO Or Smart Card Login For Active Directory Users Using RACADM

  • Configuring CMC to Use Command Line Consoles
    • CMC Command Line Console Features
      • CMC Command Line Interface Commands
    • Using Telnet Console With CMC
      • Using SSH With CMC
      • Supported SSH Cryptography Schemes
      • Configure Public Key Authentication Over SSH
        • Generating Public Keys for Systems Running Windows
        • Generating Public Keys for Systems Running Linux
        • RACADM Syntax Notes for CMC
        • Viewing Public Keys
        • Adding Public Keys
        • Deleting Public Keys
    • Configuring Terminal Emulation Software
      • Configuring Linux Minicom
        • Configuring Minicom Version 2.0
        • Required Minicom Settings
    • Connecting to Servers or I/O Module Using Connect Command
      • Configuring the Managed Server BIOS for Serial Console Redirection
      • Configuring Windows for Serial Console Redirection
      • Configuring Linux for Server Serial Console Redirection During Boot
      • Configuring Linux for Server Serial Console Redirection After Boot

  • Using FlexAddress and FlexAdress Plus Cards
    • About FlexAddress
      • About FlexAddress Plus
      • Viewing FlexAddress Activation Status
      • Deactivating FlexAddress
    • Configuring FlexAddress
      • Configuring FlexAddress for Chassis-Level Fabric and Slots
        • Configuring FlexAddress for Chassis-Level Fabric and Slots Using CMC Web Interface
        • Configuring FlexAddress for Chassis-Level Fabric and Slots Using RACADM
    • Viewing World Wide Name/Media Access Control (WWN/MAC) Addresses
      • Fabric Configuration
    • Viewing WWN/MAC Address Information
    • Viewing Basic WWN/MAC Address Information Using Web Interface
    • Viewing Advanced WWN/MAC Address Information Using Web Interface
    • Viewing WWN/MAC Address Information Using RACADM
    • Command Messages
    • FlexAddress DELL SOFTWARE LICENSE AGREEMENT

  • Managing Fabrics
    • Fresh Power-up Scenario
    • Monitoring IOM Health
    • Configuring Network Settings for IOM
      • Configuring Network Settings for IOM Using CMC Web Interface
      • Configuring Network Settings for IOM Using RACADM
    • Managing Power Control Operation for I/O Modules
    • Enabling or Disabling LED Blinking for I/O Modules

  • Managing and Monitoring Power
    • Redundancy Policies
      • Grid Redundancy Policy
        • Grid Redundancy Levels
      • Power Supply Redundancy Policy
    • Dynamic Power Supply Engagement
    • Default Redundancy Configuration
      • Grid Redundancy
      • Power Supply Redundancy
    • Power Budgeting For Hardware Modules
    • Server Slot Power Priority Settings
    • Assigning Priority Levels To Servers
    • Assigning Priority Levels To Servers Using CMC Web Interface
    • Assigning Priority Levels To Servers Using RACADM
    • Viewing Power Consumption Status
      • Viewing Power Consumption Status Using CMC Web Interface
      • Viewing Power Consumption Status Using RACADM
    • Viewing Power Budget Status Using CMC Web Interface
      • Viewing Power Budget Status Using RACADM
    • Redundancy Status and Overall Power Health
      • Power Management After PSU Failure
      • Power Management After Removing PSU
      • New Server Engagement Policy
      • Power Supply and Redundancy Policy Changes in System Event Log
    • Configuring Power Budget and Redundancy
      • Power Conservation and Power Budget
      • Maximum Power Conservation Mode
      • Server Power Reduction to Maintain Power Budget
      • 110V PSUs AC Operation
      • Remote Logging
      • External Power Management
      • Configuring Power Budget and Redundancy Using CMC Web Interface
      • Configuring Power Budget and Redundancy Using RACADM
    • Executing Power Control Operations
      • Executing Power Control Operations on the Chassis
      • Executing Power Control Operations on the Chassis Using Web Interface
      • Executing Power Control Operations on the Chassis Using RACADM
    • Executing Power Control Operations on a Server
    • Executing Power Control Operations for Multiple Servers Using CMC Web Interface
    • Executing Power Control Operations on the IOM
      • Executing Power Control Operations on IOM Using CMC Web Interface
      • Executing Power Control Operations on the IOM Using RACADM

  • Managing Chassis Storage
    • Viewing Status of the Storage Components
    • Viewing the Storage Topology
    • Viewing Fault-tolerant Troubleshooting Information of SPERC Using CMC Web Interface
    • Assigning Virtual Adapters To Slots Using CMC Web Interface
    • Fault-Tolerance in Storage Controllers
    • Viewing Controller Properties Using CMC Web Interface
    • Viewing Controller Properties Using RACADM
      • Importing or Clearing Foreign Configuration
    • Configuring Storage Controller Settings
      • Configuring Storage Controller Settings Using CMC Web Interface
      • Configuring Storage Controller Settings Using RACADM
    • Shared PERC Controllers
    • Enabling or Disabling RAID Controller Using CMC Web Interface
    • Enabling or Diasabling RAID Controller Using RACADM
    • Viewing Physical Disk Properties Using the CMC Web Interface
    • Viewing Physical Disk Drives Properties Using RACADM
    • Identifying Physical Disks and Virtual Disks
    • Assigning Global Hot Spares Using CMC Web Interface
    • Assigning Global Hot Spares Using RACADM
    • Recovering Physical Disks
    • Viewing Virtual Disk Properties Using CMC Web Interface
    • Viewing Virtual Disk Properties Using RACADM
    • Creating Virtual Disk Using CMC Web Interface
    • Applying Virtual Adapter Access Policy To Virtual Disks
    • Modifying Virtual Disk Properties Using CMC Web Interface
    • Viewing Enclosure Properties Using CMC Web Interface

  • Managing PCIe Slots
    • Viewing PCIe Slot Properties Using CMC Web Interface
    • Assigning PCIe Slots To Servers Using CMC Web Interface
    • Managing PCIe Slots Using RACADM
    • PCIe Power Ride-Through
      • Viewing PCIe Ride-through Properties Using CMC Web Interface
      • Viewing PCIe Ridethrough Properties Status Using RACADM
      • Configuring PCIe Ride-through Properties Using CMC Web Interface
      • Configuring PCIe Ride-through Properties Status Using RACADM

  • Troubleshooting and Recovery
    • Gathering Configuration Information, Chassis Status, and Logs Using RACDUMP
      • Supported Interfaces
      • Downloading SNMP Management Information Base (MIB) File
    • First Steps to Troubleshoot a Remote System
      • Power Troubleshooting
    • Troubleshooting Alerts
    • Viewing Event Logs
      • Viewing Hardware Log
        • Viewing Hardware Logs Using CMC Web Interface
        • Viewing Hardware Logs Using RACADM
      • Viewing Chassis Log
        • Viewing Chassis Logs Using RACADM
        • Viewing Chassis Logs Using the Web Interface
    • Using Diagnostic Console
    • Resetting Components
    • Saving or Restoring Chassis Configuration
    • Troubleshooting Network Time Protocol (NTP) Errors
    • Interpreting LED Colors and Blinking Patterns
    • Troubleshooting Non-responsive CMC
      • Observing LEDs to Isolate the Problem
      • Obtain Recovery Information from DB-9 Serial Port
      • Recovering Firmware Image
    • Troubleshooting Network Problems
    • Troubleshooting Controller

  • Using LCD Panel Interface
    • LCD Navigation
      • Main Menu
      • KVM Mapping Menu
      • DVD Mapping
      • Enclosure Menu
      • IP Summary Menu
      • Settings
        • LCD Language
        • Default Screen
    • Diagnostics
    • Front Panel LCD Messages
    • LCD Module and Server Status Information

  • Frequently Asked Questions
    • RACADM
    • Managing and Recovering a Remote System
    • Active Directory
    • FlexAddress and FlexAddressPlus
    • IOM

Dell Logo
Hide Table of Contents
Select a Language
  • Deutsch
  • English
  • Español
  • Français
  • 日本語
PDF
    Loading, Please wait.

    Troubleshooting Controller

    To troubleshoot a controller:
    1. In the left pane, click Chassis Overview > Storage > Controllers > Troubleshooting.
    2. On the Controller Troubleshooting page, from the Actions drop-down list for the respective controller, select any one of the following, and then click Apply.
      • Reset Configuration — Deletes the virtual disks and hots spares. However, the data on the disks is not erased.
      • Export TTY Log — The TTY debug log from the storage controller is exported to your local system.
      • Discard Pinned Cache — Deletes data that is stored in RAID controller cache.
        • NOTE: If there is pinned cache, the option to clear it is present. If there is no pinned cache, this option is not displayed.
      • Disable RAID Controller — Disables the peer controller. This option is available in the drop-down menu only for the Integrated 2 PERC when it is not disabled.
      • Enable RAID Controller — Enables the peer controller. If the Integrated 2 PERC is already disabled, then the Enable Raid Controller option is available in the drop-down menu.
        • NOTE:
        For a disabled PERC, none of the other options Reset Configuration, Export TTY Log, Discard Pinned Cache, and Disable RAID Controller are available in the drop-down menu.
    Data is not available for the Topic

    Rate this content

    Accurate
    Useful
    Easy to understand
    Was this article helpful?
    Yes No
    Please tell us whether this article solved your issue. This field is required to submit your feedback.
    Send us feedback

    Comments cannot contain these special characters: <>()\
    The verification code you entered did not match. Please try again.
    //i.dell.com/das/xa.ashx/global-site-design%20WEB/dbab1f69-52f3-6f4e-1ebb-f8c624d31e17/1/OriginalPng?id=Dell/Product_Images/eSupport/icons/esupport-alert-notice-icon.png
    Thank you for your feedback.
      Please provide ratings (1-5 stars).
      Please provide ratings (1-5 stars).
      Please provide ratings (1-5 stars).
      Please select whether the article was helpful or not.
      Comments cannot contain these special characters: <>()\
    • About Dell
    • Careers
    • Community
    • Events
    • Partner Program
    • Premier
    • Dell Technologies
    • Make a Payment
    • © 2019 Dell
    • Terms of Sale
    • Privacy Statement
    • Ads & Emails
    • Legal & Regulatory
    • Corporate Social Responsibility
    • Contact Us
    • Feedback
    • {{ lang.Text }}   |  
    • About Dell
    • Careers
    • Community
    • Events
    • Partner Program
    • Premier
    • Dell Technologies
    • Make a Payment
    • {{ lang.Text }}   |  
    • © 2019 Dell
    • Terms of Sale
    • Privacy Statement
    • Ads & Emails
    • Legal & Regulatory
    • Corporate Social Responsibility
    • Contact Us
    • Feedback